Advice for private customers: +49 2452 962-450

Advice for business customers: +49 2452 962-400

Mon - Fri: 9:00 - 17:00 (CET)

Quality engineering "made in Germany" with scientifically proven effectiveness: The room air cleaner TAC V+
  1. Products & Services
  2. Products ‑ HighPerformance
  3. Air purification
  4. High-performance air purifier TAC V+

State-of-the-art room air cleaner: High-performance air purifier TAC V+ from Trotec

The TAC V+ is the proven, effective, mobile solution for the air purification of virus-carrying aerosol particles and bacteria from the room air

State-of-the-art room air cleaner: TAC high-performance air purifiers from Trotec

Clean breathing air the best basis for effective health prophylaxis:

The TAC V+ and its model variants guarantee clean, healthier room air wherever it is needed – for mobile or stationary infection control with scientifically proven effectiveness!

99 % of all infections occur indoors. Also in the future, even in post-COVID-19 times. Clean, unpolluted breathing air is therefore essential for a good room climate and elementary health preservation. This is where the High-performance air purifiers of the TAC series offer you, your employees, customers, clients, patients and pupils a high level of protection against indirect infections by aerosol particles. The high-performance air purifier series around the TAC V+ was developed specifically for this purpose.

In addition to viruses and bacteria, the TAC V+ also reliably filters respirable and harmful particulate matter (e.g. caused by road traffic) as well as pollen from the room air. The effectiveness of the TAC room air cleaners has been confirmed in many scientific studies by leading national and international institutes.

Clean air is essential. But still, the air quality is a constant cause for alarm in many rooms.

Infectious viruses, bacteria, spores, mites and allergens plan an aerial assault on our health with every breath. But that's not all, because every time you open doors or windows, it is not only fresh oxygen entering the room but also fine dust and pollen which are a burden for your body – not just since COVID hit. More than 99 % of airborne infections and allergic reactions have always occurred indoors. It was just never noticed to the extent that everyone is now becoming aware of in the pandemic.

Thanks to their unique cleaning performance, Trotec's high-performance air purifiers such as the TAC V+ have been proven to effectively reduce the aerosol, virus, bacteria and pollutant load in the room air and significantly reduce the risk of indirect virus infection through aerosol particles.

It's not without reason that Trotec's high-performance air purifiers are recommended by numerous leading research societies and are used by top companies, in schools, ministries and healthcare facilities worldwide!

Same name, but incomparably better!

Can Germany’s best-known mobile virus air cleaner be improved even further? Trotec can do! With the current series, we are further enhancing the advantage of our TAC high-performance air purifiers.

Thermal decontamination of the new TAC V+ is now carried out by means of thermal pulsation, which reduces the performance capacity by 50 % compared to the previous model with the same decontamination effect. This means that two TAC V+ devices can now be operated simultaneously from one socket.

All TAC model variants are now equipped with an efficiency-enhancing and dual air intake duct via an integral silencer as standard equipment. The TAC models are significantly quieter and, moreover, provide an air circulation even more powerful than their previous models!

You’ll benefit from all advantages equally from both the mobile or stationary version – the perfect solution for every need: your State of the Art high-performance air purifier with its distinctive TAC quality!

TAC high-performance air purifier – State of the Art
TAC high-performance air purifier – State of the Art

High-performance air purifiers “made in Germany” for effective health protection

Trotec offers you the perfect air purification solution for every requirement:

TAC high-performance air purifiers, mobile and stationary

Not only mobile, but also stationary: high-performance air purifiers of the TAC series for highly frequented medium-sized and larger rooms

All TAC high-performance air purifiers, such as the TAC V+, are guarantors for clean, filtered and pure air and our best recommendation for effective health protection in larger rooms where many people are staying, working, playing, learning or shopping.

Different model variants ensure that the optimum TAC high-performance air purifier is available for every need.  In addition to the mobile version for easy changes of location, all models are also available as a stationary version – providing a clean design solution for clean air on the spot!

Continue to the model and design variants of the TAC high-performance air purifiers ...

Comfort high-performance air purifier AirgoClean® One

In good shape for good air: comfort high-performance air purifier AirgoClean® One for smaller shops, offices, practices, law firms or exclusive private rooms

Being one size smaller in terms of dimensions, our comfort high-performance air purifier AirgoClean® One at the same time impresses with remarkable performance data in this device class.

Performance, comfort and design combined in perfect harmony is what makes the AirgoClean® One the first choice for all users who want to ensure a healthy feel-good climate with clean, good air in their rooms and who do not want to do without convenient functions and a first-class design.

Continue to the high-performance air purifier AirgoClean® One ...


What makes the TAC V+ so unique and what makes it different from conventional air cleaners?

The TAC V+ was designed specially for the purpose of virus filtration, in particular with a view to the specific requirements in medium and large rooms such as school classrooms, office spaces or gastronomy spaces. This is why the mobile carriage design ensures large air volumes combined with high versatility. Set up, reposition, adjust – all in next to no time, always exactly where the TAC is needed.

Trotec exclusive: Thermal decontamination and filter regeneration

The specially constructed, fully encapsulated H14 high-temperature lamellae HEPA filter is a heat-resistant special design "made in Germany" with an extremely high filter volume performance of class H14 (EN 1822). Aerosols carrying viruses and bacteria are reliably filtered out and heated to about 100 °C for approx. 15 minutes at regular intervals. In this process, the viruses filtered out are denatured, i.e. practically destroyed. This takes place at the desired point in time and fully automatically, e.g. once a week at night, outside office or teaching hours.

This heating process also counteracts the formation of bacteria, biofilm and filter odours, without any harmful chemical additives or UV-C radiation. 100 °C for 100 % efficiency. Maximum hygiene for protecting the health of your children, guests, customers and employees.

TAC V+ and TAC XT offer what leading scientists recommend: "To ensure that the room air cleaner always remains hygienically safe even in continuous operation, the H14 filter (EN 1822) should be heated to an approximate filter core temperature of 100 °C for about 15 minutes. This takes place in a freely adjustable and fully automatic fashion, e.g. at night, outside office or teaching hours. Heating the filter to about 100 °C destroys the microorganisms in the filter and prevents the formation of bacteria, biofilm and fungi without harmful chemical additives or UV-C radiation", says Prof. Kähler from the University of the German Federal Armed Forces in Munich. With their automatic thermal decontamination the TAC V+ and TAC XT meet this requirement.

The advantages of the exclusive decontamination and regeneration technology from Trotec:

  • Separated microorganisms are thermally destroyed in the filter. With thermal decontamination carried out once a week, this technology only requires a small energy input amounting to approx. € 15 per year (52 x 1 kWh at € 0.28 each), but it offers you a crucial added value with regard to hygiene over the entire filter lifetime.
  • Due to the short treatment duration and the low energy input , the room temperature does not increase.
  • The filter regeneration process constitutes a kind of self-cleaning function and ensures a consistently high effectiveness of the special virus filter.
  • The thermal regeneration cycle effects the evaporation of the liquid portion of the aerosol particles and actively prevents the development of bacteria biofilm and filter odours.
  • The filter's lifetime is extended by its regeneration function, allowing for reduced maintenance intervals and lower operating costs compared to air cleaners without thermal filter regeneration.
  • Bacteria and mould can only be reliably killed at temperatures of approx. 100 °C. It's not without reason that drinking water containing germs should be boiled, i.e. heated to approx. 100 °C, for at least three to five minutes before use. Therefore, thermal decontamination and filter regeneration at approx. 100 °C offer you more safety, hygiene and a long filter lifetime.
  • Last but not least, this unique protective function basically pays for itself: Because thermal decontamination also increases the filter lifetime, a new filter has to be purchased less frequently. This saving means that you benefit from the added value of thermal decontamination – maximum filter safety and filter hygiene – practically free of charge!

With the TAC, it's not just the individual details that set standards – it's also the sum of all details

High mobility – extreme versatility – large clean air capacity – high-performance filtration – filter decontamination and regeneration – value-for-money ratio

Well thought out to a detailed level, unparalleled in its entirety: With these plus points, the TAC V+ – as is scientifically proven in several studies – ensures a technically effective and highly versatile solution to reduce the risk of infection by aerosols in closed rooms.

Always stable, and also stationary on request: mobile virus protection, flexibly applicable exactly where protection is needed

High versatility due to individually adjustable air volumes

Another decisive advantage of the TAC is the air volume that can be individually adjusted to the room volume and desired circulation rate. Regardless of the room size or application requirements, the correct and permanently constant volume flow is always available at the touch of a button for additional safety.

The TAC is uncompromisingly flexible and can be used anywhere at any time

The extremely stable, robust and scratch-resistant metal housing was specially designed for the use in environments where many people come together, work, play, learn or celebrate. This makes it possible to use all TAC high-performance air purifiers without any installation effort anywhere they're needed.

In a flexible, mobile and modular fashion, the exact number of TAC air cleaners as requested by the hygiene concept can be provided, variably adapted to the occupancy, circulation rates, background noise, room size and room geometry.

Always stable, and also stationary on request: flexible on-site virus protection

Pure floor-standing devices without a mobility option have a decisive disadvantage: They are large, heavy – and once they have been set up, they can only be relocated with great difficulty – in other words, stationary floor-mounted appliances that often weigh 200 kg and more.

The TAC V+ and its model variants are cleverly designed: here you have the choice between a mobile, wheeled version and a stationary floor-standing version. Both versions are equally stable, while the mobile version is additionally also easily movable.

Housing versions of the TAC high-performance air purifiers

Mobile version for maximum mobility

If, for example, classrooms, offices, studios or other rooms need to be rearranged, then you are perfectly equipped with a TAC high-performance air purifier in mobile design. It can be easily repositioned or completely relocated to other rooms. By only one person and without additional installation effort. If desired, the discharge height can also be flexibly adjusted using FlowExtender attachments.

Another example: If for school parties, in theatre groups, club and company celebrations or other events a higher clean air volume is temporarily required to ensure air exchange due to the larger rooms and large number of people, this is not a problem with TAC high-performance air purifiers in mobile design, as they can be flexibly positioned in any number and at any location.

Tower version for maximum safety in a fixed location

If you do not need to variably change the location of the air cleaner and air purification is to take place permanently at a fixed location, then the TAC in tower version is exactly the optimal choice for you. 50 % smaller, 50 % lighter, 100 % more stylish and yet more robust than competitive models, this version is far easier to move than other stationary air purifiers due to the integrated furniture castors. A clean design solution for clean air on the spot!

The high-performance air purifiers of the TAC series are significantly smaller and more mobile than competitive devices – with a comparable performance.
Mobile TAC high-performance air purifiers with size and weight advantages over competitive models
Whether tower (1) or stationary version (2), the discharge level of all TAC high-performance air purifiers can be optionally increased by 50 cm or 100 cm by adding either one or two additional FlowExtender Silence+ elements (3).
Needs-oriented model variants with flexible discharge heights
The mobile TAC can also be moved across floors
The mobile version of the TAC high-performance air purifiers fits through every door
Large clean air capacity, high flow pressure and an optimum flow geometry

TAC high-performance air purifiers have "the power to quickly dilute the room air"

Time is the most important factor for reducing the indirect risk of infection. And we're talking about the shortest time possible for quickly and effectively diluting the infectious aerosol accumulations that are for example generated by a super-spreader, directly at their source. This requires large volumes of clean air and a high fan performance to establish an optimized flow geometry. After all, the amount of virus-free air supplied is decisive for the occurrence of infection.

This is what the TAC high-performance air purifiers TAC V+, TAC M, TAC ECO and TAC BASIC as well as the multi air handler TAC XT offer: with a large clean air volume, an optimum flow geometry and a fan performance that is more than high enough, a circulation flow is established in the room, ensuring that the virus concentration in the room air is first diluted and is then effectively filtered with cleaned air.

Only sufficiently high circulation rates or virus-free air volumes minimize the risk of infection, this is scientifically proven. Where the effective treatment of the risks of infection by aerosol particles is concerned, high circulation rates (at least 6 times the room volume or even more, if possible) and therefore large volumes of cleaned air are indispensable — despite promises to the contrary made by other providers advertising one to three air changes per hour as sufficient.

As is proven by scientific studies, effective virus filtration requires a sufficiently dimensioned volumetric flow so as to ensure that the air cleaner can provide for the number of air changes required as is guaranteed by the TAC XT, TAC V+TAC M, TAC ECO and TAC BASIC. In this context, "air change" does not refer to a complete exchange of the air, but to the proportion of virus-filtered clean air that is supplied, relating to the room volume per hour.

FlowMatic ensures constant air circulation rates at any power level even with increasing filter pollution

In order to comply with the circulation rate required by the hygiene concept, a constant volumetric flow throughout the whole operating lifetime is indispensable. However, the filter elements of every air cleaner are successively clogged over time by coarse and fine dust (e.g. caused by traffic load). This leads to an increasing counter-pressure combined with a strongly decreasing air flow rate, inevitably reducing the level of protection envisaged.

With the innovative FlowMatic control of the TAC XT, TAC V+ and TAC M you no longer have to worry about a decreasing volumetric flow or circulation rates that fall below the values required.

Just like with the cruise control of your car, the FlowMatic sensors capture the actual air flow rate values within the entire filter ladder and consecutively adapt the system performance dynamically. In this way, the air volume target value once preset remains constant at any power level! This not only increases the filter lifetime and system efficiency, but also guarantees compliance with the circulation rate required by the corresponding hygiene concept.

Air cleaners without a FlowMatic control are not able to constantly and reliably meet the requirements so as to comply with the circulation rate required. This is why the filters of such models must be checked at regular intervals and changed if necessary for safety reasons.

Air change recommendations for different rooms
High-performance filtration: H14 means maximum HEPA filter efficiency

TAC high-performance air purifiers can "effectively separate" viruses

Heat-resistant H14 HEPA high-performance filter

Exclusively H14 HEPA high-performance filters complying with EN 1822 specifications (ISO 45H filter ISO 29463) like they are used for example in the TAC V+ are able to even filter the tiny virus-infected aerosol particles (0.1 - 0.2 µm) from the room air, and this at a percentage of 99.995 %. Therefore the filter efficiency of H14 HEPA filters complying with EN 1822 is 10 times higher than that of H13 HEPA filters with 99.95 %, as used in most air cleaners!

99.995 % or 99.95 %? This may not sound like a lot, but exactly these two decimal places make the big difference between H13 and H14 HEPA filters! Virus-carrying aerosol particles are extremely tiny. And "virus filters" are designed to "filter viruses". That's why TAC high-performance air purifiers not only filter the large, but also the small-sized, highly infectious aerosols from the room air not even filtered out by FFP2 and FFP3 respiratory masks, which therefore don't offer genuine protection. Real safety is exclusively provided by an H14 HEPA filter (EN 1822)!

Scientific studies, however, qualify that a filter performance beneficial to the decay rate pursued can only be confirmed if the volume flow of the air cleaner and the flow speed in the particulate air filter are sufficiently attuned to one another by an adequately dimensioned filter surface, a property which is offered by the high-performance air purifiers TAC V+, TAC M, TAC ECO and TAC BASIC or the multi air handler TAC XT!

Thermal filter decontamination – your safety airbag

Unique technology – Trotec exclusive

The thermography image illustrates this: In the process of thermal decontamination the heat-resistant H14 virus filter of the TAC V+ is heated to about 100 °C, destroying the bound microorganisms.
Fully encapsulated H14 high-temperature particulate air filter, equipped with heat-conducting metal lamellae

Only with the TAC V+ and TAC XT the special, fully encapsulated H14 high-temperature lamellae high-efficiency particulate air filter is treated thermally at regular intervals. Explicitly for this purpose, this filter has been developed and interspersed with special, heat conducting metal fins.

This thermal filter decontamination technology offers you several benefits at the same time! By heating the filters, the proteins of the viruses filtered out, which are relevant to the infectiousness, are denatured, and the viruses are practically destroyed. Therefore infectious viruses can no longer enter the ambient air from the filter, for example by improper handling during a filter change. Furthermore, bacteria, germs and other microorganisms are additionally destroyed. Filter decontamination at temperatures much lower than 100 °C would not be sufficient here. It's not without reason that drinking water containing germs, for instance, should be boiled, i.e. heated to about 100 °C, for at least three to five minutes before use.

All this means extra employee protection can be ensured during operation and also when the filter is changed! You could say, it's the "virus airbag" that provides for more safety. It is there when you need it – and as long as nothing happens, you won't even notice it.

Scientific studies substantiate the usefulness of thermal filter decontamination for ensuring effective virus filtration. Professor Christian Kähler, for example, points out: "To ensure a maximum degree of hygiene and a longer lifetime in continuous operation, the H14 filter should be heated to approx. 100 °C every day for about 15 minutes, in order to prevent the formation of biofilms, bacteria and fungi without using harmful chemical additives or UV-C radiation."

We recommend carrying out thermal decontamination once a week. Only in hygienically sensitive areas with a low air temperature and very high humidity level should thermal decontamination be carried out once a day. Thermal decontamination of the filter carried out on a weekly basis requires only 1.0 kW of additional energy per week and will not increase the room temperature.

The decisive plus in terms of safety and hygiene for only 28 cents per day, which moreover pay for themselves

The on-demand thermal filter decontamination offers the decisive plus in terms of safety and filter hygiene! And yet, the additional energy input required is negligible. Even with thermal decontamination carried out daily, the costs only amount to 1 kWh, i.e. 28 cents per day of use. And if thermal decontamination is carried out once a week, the costs are just under € 15 per year.

Because thermal decontamination also increases the filter lifetime, a new filter has to be purchased less frequently. This saving means that you benefit from the added value of thermal decontamination – maximum filter safety and filter hygiene – practically free of charge!

Thermal filter regeneration – for optimum filter hygiene and a prolonged filter lifetime

No filter humidity, no filter mould or odour, and at the same time a much longer filter lifetime

Thermal filter decontamination and thermal filter regeneration

Aerosol separators and virus air cleaners take effect where many people are present in narrow spaces over a longer time and exhale larger quantities of aerosols. Aerosols, whether virus-carrying or not, for the greater part consist of micro droplets – pure water, that is. Customary H14 filters may be able to "catch" these humid aerosols, however, they also catch additional problems. Since the increasing humidity in the filter causes it to start fouling more quickly. As a result, the filter resistance increases, constantly reducing the clean air volume emitted and thus significantly reducing the filter lifetime. The fast fouling of filters at high loads of aerosols has been scientifically proven by field tests.

Moreover, the constantly high level of humidity favours the formation of filter mould or biofilms. Instead of eliminating a hazard, others may therefore be created. For example, a decreasing flow rate, shorter filter lifetimes and mould on the filter. But since the filter is heated to more than 100 °C at regular intervals, the ingress of moisture, fast sooting and filter mould are not a problem with the TAC V+ and TAC XT. Since the humidity is fully discharged again in the course of the thermal regeneration cycle, not only drying the filter at regular intervals, but additionally regenerating it again via its self-cleaning function.

With this innovative procedure the filter resistance remains low and the clean air flow remains at a constantly high level for a considerably longer time. Consequently the lifetime is longer than that of other filter systems without thermal regeneration and decontamination. This is also confirmed by current studies, which sum up as follows in the context of an examination of the TAC V+ and its H14 filter which complies with the specifications of EN 1822 (ISO 45H filter ISO 29463) and which features a self-cleaning function: "Therefore it is to be expected that this filter can have a lifetime of several years, depending on the load."

Maximum filter hygiene for just 28 cents per day, which practically pay for themselves

Thermal decontamination and regeneration of the filter requires only 1 kWh of energy. Even if thermal decontamination is carried out once a day, the costs amount to approx. 28 cents per day of use, and if thermal decontamination is carried out once a week, the costs amount to just under € 15 per year. At the same time, however, the unique thermal filter decontamination and filter regeneration offers you the decisive added value in terms of safety and hygiene over the entire filter lifetime. And all this is basically at zero cost, because the longer filter lifetime achieved by regular thermal filter regeneration means that a new filter does not have to be purchased as often – this saving means that you benefit from the added value of thermal decontamination – maximum filter safety and filter hygiene – practically free of charge!

Extra safety: efficiency-tested air purification principle

In a continuous process, the room air that is contaminated with aerosol particles and infectious viruses is diluted and pushed towards the floor by a kind of "air roll effect". Like all TAC high-performance air purifiers the TAC V+ draws in large volumes of the contaminated air near the floor and already cleans them in the course of one air cycle with its H14 filter efficiency of 99.995 %, certified in compliance with EN 1822, reliably separating airborne germs.

The clean, virus-filtered clean air then flows back to the top of the room with a high fan performance. This air cycle continuously keeps the breathing air cleaner, especially at head height, than without filtration. The filtered, blown-out air in this process is not only free from viruses but also free from pollen and respirable, harmful particulate matter that always enters the room from outside every time you open doors or windows.

Clean, healthier air: more protection against indirect infection

With the TAC V+ you can adjust the required amount of clean air to your demands. The device, which can be configured via a touch display, can be easily programmed by "touch & play" to match individual demands, making it possible to adapt the air volume according to the individual situation at any time. And thanks to the integrated boost function, targeted short and intensive filtration can be carried out, e.g. during break times or in the case of room changes, for quick separation with a maximum air volume.

From a scientific point of view, effective virus air purification requires at least 6 air circulations per hour and a HEPA filter of class H14. Both the air cleaner and the H14 filter must therefore provide an air flow rate that is at least six times higher than the air volume of the room. In the case of a higher density of persons or a high level of physical activity, a higher circulation rate is recommended in order to ensure safety.

Large clean air capacity for effective air purification

Whether it is to be used for schools, offices, fitness studios or restaurants, the TAC V+ is ideally equipped for every requirement, because, like all TAC high-performance air purifiers, it features reserve capacities which allow for 10 or more air circulations per hour even in larger rooms.

Low-noise: Hard to believe, hardly to be heard

The TAC V+ is an air cleaning revolution of the silent kind

Sound protection hood to ensure silent operation

The task of qualified high-performance air purifiers is to make the utilization of interior spaces possible again – and not to make it more difficult! Nevertheless, without large volumes of clean air, the risk of infection cannot be minimized!

When aerosol particles are separated or viruses and bacteria are filtered out, high air circulation rates between 6 and 8 per hour are required, and in the medical sector even 12- to 15-fold air circulation rates per hour. It is important to note that the virus-free room air volume, which determines the risk of infection, results from the circulation rate and the room volume. Without these large air circulation rates, spontaneously occurring aerosol clouds cannot be reliably and quickly diluted and filtered out.

Therefore, even in smaller rooms of 45 m² you already need amounts of clean air from 700 m³ to 1,500 m³, which requires a fan with a correspondingly high ventilation power. In particular, to establish an optimum air flow and air routing in the room. In addition to the flow geometry, filter efficiency and long filter lifetimes, however, an acceptable noise level, in spite of the large air volumes and the high fan performance, is desirable.

Therefore, low noise emission was a top priority when the TAC high-performance air purifiers were designed

All models – whether mobile or stationary – have been subjected to an elaborate sound insulation concept and are now equipped with an integral silencer on the suction side as standard equipment. All in all, this makes the new TAC generation hardly noticeable in everyday use and by far the quietest devices on the market in relation to air flow rate/device size.

For noise sensitive areas such as schools, offices or medical practices we recommend using the optional sound protection caps by means of which the sound level experienced subjectively can be lowered even further. In workshops, packing stations or discotheques, etc. the use of the sound protection caps usually is not required.

With the optional sound protection caps, the TAC V+, for instance, produces only approx. 30 dB, depending on the power level. For comparison: A customary laser printer already generates a sound level of approx. 50 dB during operation.

Well thought out to the detail, unparalleled in its entirety – all advantages of the TAC V+ at a glance

High versatility due to mobility

Easy set-up and moving instead of cumbersome set-up and conversion – decisive advantages over stationary, large and heavy floor-mounted appliances: versatility. Thanks to the carriage design, the "Plug & Play" device can be used for both mobile and stationary applications – simply set it up flexibly exactly where protection is needed. For the installation sites and application purpose can change again and again, and effective hygiene concepts therefore require a high degree of flexibility. The TAC is a true mobile device, and therefore always quick and easy to set up exactly where protection is needed.

High versatility due to individually adjustable air volumes

Another decisive advantage of the TAC are the air volumes that can be individually adjusted to the room volume and desired circulation rate. Regardless of the room size or application requirements, the correct and permanently constant volume flow is always available at the touch of a button for additional safety.

Significantly increased health protection also against fine dust

The TAC high-performance air purifier from Trotec offer you, your employees, customers, clients, patients and pupils a high level of protection against indirect infection by aerosol particles. In addition to viruses and bacteria, also respirable and harmful particulate matter (e.g. caused by road traffic) as well as pollen are reliably filtered from the room air.

More safety – scientifically tested and recommended

The effectiveness of the room air purifier TAC V+ has been confirmed in several independent scientific studies carried out by leading national and international institutes.

Large clean air capacity – high pressure

Up to 2,100 m³/h of clean air filtered free from viruses and bacteria by a high fan performance for optimum air circulation, air flow and frequent air circulation. Proper air flow and routing are an absolute must when you want to ensure a high degree of safety. In particular the high maximum air flow rate (boost mode) is ideally suited for quick separation (short and intense filtration) in break periods or in the case of room changes.

Effective high-performance filtration with the maximum HEPA filter class, certified in compliance with EN 1822

In the TAC V+, TAC M and TAC XT, fully encapsulated H14 metal fin high-temperature filters "made in Germany" with flow-optimized high-tech filter material are used, which are specially developed for Trotec. Each quality filter is tested and certified individually.

FlowMatic control: Constant circulation rates in all power levels by a constant volumetric flow to provide for increased safety

The sensor-supported FlowMatic control in the TAC V+, TAC M and TAC XT works like the cruise control in the car: Even when coarse and fine dust increasingly pollute the filter you don't have to be concerned about a decreasing air flow rate or about values falling below the required air changes.

The system performance is adapted continuously and dynamically, ensuring that the air volume target value once set is kept constant at any power level! For increased safety, longer filter lifetimes and a substantially higher system efficiency.

Exclusively with TAC V+ and TAC XT: Thermal filter decontamination for more safety

Just like the airbag in the car – you hardly ever need it, but it's important that it's there! Reliable inactivation of the viruses and bacteria by heat (15 minutes at about 100 °C) provides an important added value where hygiene and safety are concerned. This is recommended by leading scientists to ensure safe continuous operation.

Thermal filter decontamination is freely programmable and is effected in a fully automatic fashion, e.g. outside business hours or school hours.

Thermal decontamination carried out on a weekly basis requires only 1.0 kWh of additional energy per week and will not increase the room temperature due to the limited energy input and the short treatment time.

Exclusively with TAC V+ and TAC XT: Thermal filter regeneration for more hygiene

Automatic self-cleaning of the filter to provide for a longer filter lifetime and to prevent bacteria, mould, biofilm and the formation of odours resulting therefrom.

The process of filter regeneration takes place at about 100 °C in parallel to the thermal decontamination process and is recommended from a scientific point of view, since most bacteria and microorganisms are only inactivated at a temperature of approx. 100 °C. It's not without reason that drinking water containing germs should be boiled, i.e. heated to approx. 100 °C, for at least three to five minutes before use.

Thermal filter regeneration: To provide for longer filter lifetimes and an improved filter hygiene, and to prevent filter odour.

Fully automatic operation by flexible programming

Thanks to the fully programmable and updateable touch display, the TAC V+, TAC M and TAC XT can be adapted individually to your operating hours and rest periods, so that you no longer have to worry about anything.

Low noise emission

Due to the integral silencer integrated as standard, TAC high-performance air purifiers are by far the most silent devices on the market in relation to the air flow rate/device size. In addition, optional sound protection caps even enable ultra-silent operation.

Robust design for professional use

Extremely robust, stable and scratch-proof metal housing specially designed for operational environments where many people are staying, working, playing, learning or celebrating. Optionally also available as tamper-proof versions for schools, daycare centres, etc.

Also available as compact tower version

In addition to the mobile version, all TAC high-performance air purifiers are also available as a compact tower version for stationary continuous operation. Just as powerful as their mobile counterparts, these devices for stationary continuous operation with heights of barely one metre blend harmoniously and stylishly into any environment.

TAC V+ and TAC XT: low running costs

The running costs of the TAC V+ and TAC XT are very low. Firstly, the average power consumption for the basic operation of the device (fan, electronics, etc.) is only 150 Wh. Some competition models may have a nominally lower consumption, but given their high clean air capacity, the TAC V+ and TAC XT are extremely cost-effective in terms of cost per cubic metre of virus-filtered clean air.

Secondly, the on-demand thermal decontamination with simultaneous filter regeneration not only offers the decisive plus in terms of safety and filter hygiene – but also enormous savings potential! Activated once a week, filter decontamination generates additional energy costs of just under € 15 a year (approx. 1 kWh/week). At the same time, filter hygiene is improved and filter lifetime increased. A new filter has to be purchased less frequently, and this saving means that you benefit from the added value of thermal decontamination – maximum filter safety and filter hygiene – practically free of charge!


Possible applications and equipment differences of TAC high-performance air purifiers at a glance

Trotec high-performance air purifiers with HEPA H14 suitability in compliance with EN 1822 (corresponds to ISO 45 H according to ISO 29463) TAC XT TAC V+ TAC M TAC ECO TAC BASIC
TAC XT TAC V+ TAC M TAC ECO TAC BASIC
Use for high-performance H14 HEPA air purification as per EN 1822
Integral silencer
Stationary stand version
Mobile carriage design
Usage-related filter change indicator for prefilter and HEPA filter
FlowMatic volumetric flow control
Programmable touch display updateable via USB
Thermal filter decontamination and filter regeneration
Use for room heating, tent heating (heating capacity 18/27 kW)
Use for thermal decontamination of rooms and objects
Use for thermal disinfestation
Trotec high-performance air purifiers with HEPA H14 suitability in compliance with EN 1822 (corresponds to ISO 45 H according to ISO 29463) TAC XT TAC V+ TAC M TAC ECO TAC BASIC
Use for high-performance H14 HEPA air purification as per EN 1822
Integral silencer
Stationary stand version
Mobile carriage design
Usage-related filter change indicator for prefilter and HEPA filter
FlowMatic volumetric flow control
Programmable touch display updateable via USB
Thermal filter decontamination and filter regeneration
Use for room heating, tent heating (heating capacity 18/27 kW)
Use for thermal decontamination of rooms and objects
Use for thermal disinfestation
TAC high-performance air purifiers – show more technical data
TAC high-performance air purifiers – more technical data at a glance TAC XT TAC V+ TAC M TAC ECO TAC BASIC
TAC XT TAC V+ TAC M TAC ECO TAC BASIC
Max. air flow rate heating (without HEPA filter) 2,500 m³/h - - - -
Max. air volume flow for the respective filter class with HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
H14 ≤ 1,000 m³/h
H13 ≤ 1,600 m³/h
Prefilter G4 Z-line
(EN 779:2002)
F7 (EN 779:2002), ePM10 85 % (ISO 16890) G4 Z-line
(EN 779:2002)
High-temperature particulate air filter TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”

Each filter is tested and certified individually.
TROTEC HEPA H14, EN 1822
(standard minipleat)
Each filter is tested and certified individually.
Filter change interval approx. 2 to 4 years
(depending on the application and with regular thermal decontamination)
approx. 1 to 3 years
(depending on the application)
approx. 1 to 2 years
(depending on the application)
max. 1 to 2 years
Filter change indication Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter -
FlowMatic control Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
Time freely programmable,
the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours.
Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required.

Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination.
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug) 380–480 V 50 / 60 Hz (CEE 32 A) 220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption Air purification: 0.15 kW*, 1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
heating: max. 27 kW
0.15 kW*,
1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
Without thermal decontamination approx. 1.2 kWh per day / approx. 24 kWh per month*

With thermal decontamination approx. 1.4 kWh per day / approx. 28 kWh per month
* and thermal decontamination once a week
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel Programmable, USB updateable touch display with PIN-protected lock function Manual control panel
(6-step switch)
Dimensions L x W x H
With wheels and handle
(mobile housing)

690 mm x 630 mm x 1,300 mm to 2,300 mm **

Width with optional sound protection caps: 770 mm

690 mm x 630 mm x 1,130 mm to 2,300 mm **

Width with optional sound protection caps: 770 mm
Dimensions L x W x H
(stationary housing)

506 x 523 x 1,100 mm to 2,300 mm **

Width with optional sound protection caps: 770 mm
Weight
(mobile housing)

TAC XT 18:
104 kg (incl. filter)

TAC XT 27:
109 kg (incl. filter)

89 kg (incl. filter) 86 kg (incl. filter) 83 kg (incl. filter)
Weight
(stationary housing)
85 kg (incl. filter) 81 kg (incl. filter) 78 kg (incl. filter) 73 kg (incl. filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC XT
Max. air flow rate heating (without HEPA filter)
2,500 m³/h
Max. air volume flow for the respective filter class
with HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
Prefilter
G4 Z-Line (EN 779:2002)
High-temperature particulate air filter
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”
(optional also as Ultra-HighFlow filter).
Each filter is tested and certified individually.
Filter change interval
Approx. 2 to 4 years
(depending on the application and with regular thermal decontamination)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
Time freely programmable,
the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours.
Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required.

Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination.
Mains connection (connector plug)
380–480 V 50 / 60 Hz (CEE 32 A)
ø power consumption
Air purification: 0.15 kW*, 1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
heating: max. 27 kW
Exemplary total energy consumption
(with 900 m³/h air volume)
Without thermal decontamination approx. 1.2 kWh per day / approx. 24 kWh per month*

With thermal decontamination approx. 1.4 kWh per day / approx. 28 kWh per month
* and thermal decontamination once a week
Control panel
Programmable, USB updateable touch display with PIN-protected lock function
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 mm x 630 mm x 1,300 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
Weight (mobile housing)
TAC XT 18: 104 kg (incl. Filter)
TAC XT 27: 109 kg (incl. Filter)
Weight (stationary housing)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC V+
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
with HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
Prefilter
F7 (EN 779:2002), ePM10 85 % (ISO 16890)
High-temperature particulate air filter
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”
(optional also as Ultra-HighFlow filter).
Each filter is tested and certified individually.
Filter change interval
Approx. 2 to 4 years
(depending on the application and with regular thermal decontamination)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
Time freely programmable,
the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours.
Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required.

Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination.
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*,
1.25 kW (short-term peak load, e.g. once a week during thermal decontamination)
Exemplary total energy consumption
(with 900 m³/h air volume)
Without thermal decontamination approx. 1.2 kWh per day / approx. 24 kWh per month*

With thermal decontamination approx. 1.4 kWh per day / approx. 28 kWh per month
* and thermal decontamination once a week
Control panel
Programmable, USB updateable touch display with PIN-protected lock function
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 x 630 x 1,300 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
89 kg (incl. Filter)
Weight (stationary housing)
85 kg (incl. Filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC M
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
with HighFlow H14 HEPA Heat Resistant filter:
H14 ≤ 1,200 m³/h, H13 ≤ 2,100 m³/h
Prefilter
F7 (EN 779:2002), ePM10 85 % (ISO 16890)
High-temperature particulate air filter
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822
Fully encapsulated H14 HighFlow metal lamellae high-temperature filter “made in Germany”
(optional also as Ultra-HighFlow filter).
Each filter is tested and certified individually.
Filter change interval
Approx. 1 to 3 years (depending on the application)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Constant clean air volume flow,
constant circulation rates in each power level

also with increasing filter contamination. Air volume freely adjustable in m³.
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel
Programmable, USB updateable touch display with PIN-protected lock function
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 x 630 x 1,300 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,100 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
86 kg (incl. Filter)
Weight (stationary housing)
81 kg (incl. Filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC ECO
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
H14 ≤ 1,000 m³/h
H13 ≤ 1,600 m³/h
Prefilter
G4 Z-line (EN 779:2002)
High-temperature particulate air filter
TROTEC HEPA H14, EN 1822
(standard minipleat)
Each filter is tested and certified individually.
Filter change interval
Approx. 1 to 2 years(depending on the application)
Filter change indication
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter
FlowMatic control
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel
Manual control panel (6-step switch)
Dimensions L x W x H (mobile housing)
With wheels and handle:
690 x 630 x 1,130 mm to 2,300 mm **
Width with optional sound protection caps: 770 mm
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,100 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
83 kg (incl. Filter)
Weight (stationary housing)
78 kg (incl. Filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
TAC BASIC
Max. air flow rate heating (without HEPA filter)
-
Max. air volume flow for the respective filter class
H14 ≤ 1,000 m³/h
H13 ≤ 1,600 m³/h
Prefilter
G4 Z-line (EN 779:2002)
High-temperature particulate air filter
TROTEC HEPA H14, EN 1822
(standard minipleat)
Each filter is tested and certified individually.
Filter change interval
Max. 1 to 2 years
Filter change indication
FlowMatic control
Safety and filter hygiene:
Thermal decontamination and filter regeneration at approx. 100 °C.
15 min. heating-up phase /
15 min. decon phase (altogether 30 min.)
No thermal decontamination and
reconditioning of the filter
Mains connection (connector plug)
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F)
ø power consumption
0.15 kW*
Exemplary total energy consumption
(with 900 m³/h air volume)
approx. 1.2 kWh per day /
approx. 24 kWh per month*
Control panel
Manual control panel (6-step switch)
Dimensions L x W x H (mobile housing)
Dimensions L x W x H (stationary housing)
506 x 523 x 1,100 mm to 2,100 mm **
Width with optional sound protection caps: 770 mm
Weight (mobile housing)
Weight (stationary housing)
73 kg (incl. filter)
* for a 5-day week with 8 h operating time per day and 900 m³ air volume ** depending on the FlowExtender Silence+ attachment
Available colour variants
TAC XT
Available colour versions
Yellow
Also available as stainless steel version
TAC V+
Available colour versions
Yellow, basalt grey, white, bronze
Also available as stainless steel version
TAC M
Available colour versions
Yellow, basalt grey, white, bronze
Also available as stainless steel version
TAC ECO
Available colour versions
Basalt grey
Also available as stainless steel version
TAC BASIC
Available colour versions
Basalt grey
Also available as stainless steel version

Good references are the best recommendation – see for yourself who relies on our products where the protection of employees, customers and children is concerned!

Good references are the best recommendation

TAC V+ with scientifically certified effectiveness!

Scientifically proven effectiveness: The TAC V+ offers what leading scientists recommend

The mobile air cleaner TAC V+ was specially designed for the purpose of virus filtration and, in this respect, has been tested for its effectiveness in the context of several scientific studies. Comprehensive studies confirm the effectiveness of the TAC V+ with its H14 filter system “made in Germany”. Learn more about the scientifically certified effectiveness of the TAC V+ ...


TAC V+ media library

The TAC V+ puts things into motion – an exceptional amount of virus-free clean air, satisfied customers and various media

In our media library for the TAC V+ you'll find some videos explaining the functional principle of the TAC V+ and its effective principle of air purification. In addition, we have compiled a large variety of different information videos describing the use of the TAC V+ in different fields of application like restaurants, supermarkets or fitness studios. Furthermore the TAC V+ media library will provide you with recommendation videos by satisfied users and with a selection of different media reports about the air cleaner TAC V+. Come and see for yourself ...



Breathe healthier, live healthier – turn rooms into climatic health resorts!

Breathe healthier, live healthier!

Turn rooms into climatic health resorts! A place where you feel safe and where you know that there is no danger from the air. Because “good air” has never been as valuable as it is today, and that will not change tomorrow!

Here you will find convincing arguments why investing in good air is always worthwhile ...

Major trend good air

Major trend good air

Even in times “without COVID-19”, Trotec’s high-performance air purifiers will still be a precious investment as a universal guarantor of clean air – for good reason!

Find out here why air purification is so important for health protection – and will remain so even in post-COVID-19 times ...

Fine dust – the invisible danger

Fine dust – the invisible danger

Fine dust is one of the world’s biggest environmental risks. Harmful levels of particulate matter in the outdoor air also cause indoor levels to rise.

More information regarding the fine dust issue can be found here ...


What's the point of air purification? All you need to do is ventilate properly, right? Pros and cons:

Airing seems to be the order of the day in Corona times. This recommendation is continuously propagated by various parties and presented as the most effective measure to reduce the risk of airborne infection indoors. In fact, ventilation can reduce the concentration of virus-laden aerosols in the room air. However, only if all conditions are met, which is often not the case. Airing versus air filtration – all facts at a glance: On our info page on the subject of "Airing or air purification" we have compiled the most important aspects of the technical possibilities of room ventilation for you. Learn everything you need to know about intensive airing, cross ventilation, ventilation duration, on-site requirements, climatic conditions and effectiveness – here you can see for yourself ...

Airing or air purification? Everything you need to know on our info page ...

Trotec exclusive: acrylic glass shield with an all-round aerosol protective edge
More protection with all-round aerosol protective edge
Less protection without all-round aerosol protective edge
Trotec exclusive: acrylic glass shield with an all-round aerosol protective edge

360-degree hygiene solution for optimum all-round protection

Your safety plus: TAC V+ air cleaner – plus acrylic glass shields with an all-round aerosol protective edge

Unlike conventional transparent protective screens, the acrylic glass shields exclusively available only at Trotec offer you significantly more protection against flying droplets and aerosols suspended in the room air thanks to their unique all-round aerosol protective edge.

The high efficiency yielded by the combination of a high-performance air purifier TAC V+ and installed acrylic glass shields from Trotec "made in Germany" has been scientifically proven. Our recommendation as an optimum all-round protection solution for schools, offices, retail and many more ...


Trotec solutions do not only allow you to generate clean and purified air, but also make the quality of the room air visible!

Triple indicator for healthy room air: Our BQ air quality measuring devices indicate all important values

Particle measuring device BQ30 for air quality monitoring

The Air quality monitor BQ30 should not be missing on any teacher's desk or in any open-plan office because this environmental monitoring station shows you the most important values for healthy room air at a glance: In addition to the current CO2 load and the prevailing climate data and the particulate matter pollution in particle size PM2.5 or PM10 are shown to you.

The CO2 pollution is an important indicator of required ventilation measures and the fine dust particle sizes determined also include pollen, a helpful feature to monitor the air quality for allergy sufferers! In rooms with a large number of persons, CO2 Traffic lights can serve as a means for rough-orientation to indicate whether the air quality is good or poor, as carbon dioxide (CO2) is a reliable indicator of an air change.

In addition to the BQ30 Trotec's range of products includes further professional particle counters such as the PC200 or the PC220. Our particle counters cannot only be used for inspecting the air quality, but to test filter systems as well, for example.

Note: Neither the degree of air pollution caused by particulate matter of the particle size PM2.5 nor the CO2 pollution in the room tells you anything about the infection risk! None of the two values are a measurand of the risk of infection, since there is no correlation between CO2 or PM2.5 concentration and viral load. Learn more about this subject area and several others with regard to virus filtration, filter classes, filter standards and other important operating figures – summarized in our air cleaner-FAQ for virus filtration ...

Air cleaner FAQ for virus filtration

Learn more about the technical possibilities of virus air filtration

You want to know which technical aids offer effective protection against viruses in the room air? Do you have any questions with regard to the different cleaning methods offered on the market, their functional principle and their suitability for virus filtration? Visit our air cleaner-FAQ for virus filtration – Here you'll find answers to all of your questions with regard to air purification, virus filtration, standards as well as filter classes and of course the high-performance air purifier TAC V+ ...

We would be happy to advise you personally and calculate the best leasing offer for you

Work more securely with our TAC business leasing from €49 per month*

More freedom through flexible financing at top conditions is made possible by our TAC business leasing with instalments from €49*. We would be happy to advise you personally and calculate the best leasing offer for you: +49 2452--962--730      * plus VAT with 0 % down payment. For traders only

* We will automatically check whether there are federal or state funding programmes available for your application area.

With the high-performance air purifiers of the TAC series Trotec offers professional solutions for aerosol-free filtered clean air quality in larger rooms such as schools, restaurants, offices, medical practices or hotels. By providing virus-filtered clean air, the TAC V+ ensures a high level of protection for employees and customers, teachers and students, staff and patients in commercial environments and public facilities. But even in smaller rooms you can benefit from our expertise in air purification and virus filtration:

AirgoClean® – the synonym for clean breathing air: unpack, switch on, breathe freely

With AirgoClean® you have a wide range of excellent Trotec air purification units at your disposal. First and foremost the AirgoClean® One – our number 1 high-performance air purifier for virus-filtered clean air in exclusive environments, medical practices and law firms. The air cleaners of the AirgoClean® brand stand for effective filter performance, high user comfort and proven Trotec quality – reliable protection against room air polluted with house and fine dust, bacteria, airborne viruses or pollen. Our large selection of air cleaners offers the ideal AirgoClean® device for every need ...

AirgoClean® – the synonym for clean air – unpack, switch on, breathe fresh air

Trotec: Innovation made in Germany

Take a look behind the scenes:

As one of the internationally leading manufacturers of air treatment solutions, Trotec offers industrial and commercial customers innovative products for air purification, dehumidification, heating, air conditioning and ventilation. We rely 100 % on research, development, design and production in Germany for our high-performance devices. For the highest quality requirements, sophisticated system solutions and fresh ideas.

Watch the video to see for yourself!

Buy

Techn. data TAC V+

Mobile version

Technical data
General information
  Article number 1.580.001.152
Dust class
  as per DIN EN 60335-2-69 H
  as per DIN EN 1822 (ISO 45H filter ISO 29463) H14
  as per DIN EN 779:2002 F7
Air flow rate
  Max. air volume flow [m³/h] 2,100
  Suitable for rooms sized up to [m²/m³] with H14 filter class 80 m² /200 m³
  Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] 1,200
  Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h]] 2,100
Electrical values
  Mains connection 220 - 240 V, 50/60 Hz
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Power consumption with thermal decontamination (60 min) [kW] 1.25
  Nominal current consumption [A] 5.5
  Recommended fusing [A] 10
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  Depending on the configuration (sound protection caps, FlowExtender) 29 - 50 dB(A)
Fan
  Radial
  axial
  stages 7
Safety feature
  Protection class IP20
Dimensions
  Length (packaging excluded) [mm] 690
  Width (packaging excluded) [mm] 610
  Height (packaging excluded) [mm] 1,300
Weight
  (packaging excluded) [kg] 89
Equipment, features and functions
Equipment
  Thermal filter decontamination
  Thermal filter regeneration
  Touchscreen
  Usage-related, sensor-controlled filter change indication of the F7 prefilter
  Usage-related, sensor-controlled filter change indication of the H14 main filter
  FlowMatic control
  Timer switch for the device is flexibly adjustable
  Timer switch for thermal decontamination is flexibly adjustable
  Operating hours counter
  Update of the control software via USB flash drive
  Language setting
  Key lock
  Silence mode
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Hygienic areas (≥ 15 ACH) F7 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Carry/transport handle(s)
  Trestle rollers/ fixed castors
  Non-marking rubber wheels/rollers
  Foot
  Protective bar at the control panel
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame

 standard equipment

 optionally available

 not available

Tower version

Technical data
General information
  Article number 1.580.010.152
Dust class
  as per DIN EN 60335-2-69 H
  as per DIN EN 1822 (ISO 45H filter ISO 29463) H14
  as per DIN EN 779:2002 F7
Air flow rate
  Max. air volume flow [m³/h] 2,100
  Suitable for rooms sized up to [m²/m³] with H14 filter class 80 m² /200 m³
  Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] 1,200
  Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h] 1,800
Electrical values
  Mains connection 220 - 240 V, 50/60 Hz
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Power consumption with thermal decontamination (60 min) [kW] 1.25
  Nominal current consumption [A] 5.5
  Recommended fusing [A] 10
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  Depending on the configuration (sound protection caps, FlowExtender) 29 - 50 dB(A)
Fan
  Radial
  axial
  stages 7
Safety feature
  Protection class IP20
Dimensions
  Length (packaging excluded) [mm] 506
  Width (packaging excluded) [mm] 523
  Height (packaging excluded) [mm] 1,270
Weight
  (packaging excluded) [kg] 89
Equipment, features and functions
Equipment
  Thermal filter decontamination
  Thermal filter regeneration
  Touchscreen
  Usage-related, sensor-controlled filter change indication of the F7 prefilter
  Usage-related, sensor-controlled filter change indication of the H14 main filter
  FlowMatic control
  Timer switch for the device is flexibly adjustable
  Timer switch for thermal decontamination is flexibly adjustable
  Operating hours counter
  Update of the control software via USB flash drive
  Language setting
  Key lock
  Silence mode
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Hygienic areas (≥ 15 ACH) F7 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Carry/transport handle(s)
  Trestle rollers/ fixed castors
  Non-marking rubber wheels/rollers
  Foot
  Protective bar at the control panel
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame

 standard equipment

 optionally available

 not available

Techn. data TAC M

Mobile version

Technical data
General information
  Article number 1.580.001.145
Dust class
  as per DIN EN 1822 (ISO 45H filter ISO 29463) H14
  as per DIN EN 779:2002 F7
Air flow rate
  Max. air volume flow [m³/h] 2,100
  Suitable for rooms sized up to [m²/m³] with H14 filter class 80 m² /200 m³
  Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] 1,200
  Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h]] 2,100
Electrical values
  Mains connection 220 - 240 V, 50/60 Hz
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Nominal current consumption [A] 3.5
  Recommended fusing [A] 6
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  Depending on the configuration (sound protection caps, FlowExtender) 29 - 50 dB(A)
Fan
  Radial
  axial
  stages 7
Safety feature
  IP23
Dimensions
  Length (packaging excluded) [mm] 690
  Width (packaging excluded) [mm] 610
  Height (packaging excluded) [mm] 1,300
Weight
  (packaging excluded) [kg] 84
Equipment, features and functions
Equipment
  Touchscreen
  Usage-related, sensor-controlled filter change indication of the F7 prefilter
  Usage-related, sensor-controlled filter change indication of the H14 main filter
  FlowMatic control
  Timer switch for the device is flexibly adjustable
  Key lock
  Update of the control software via USB flash drive
  Operating hours counter
  Language setting
  Silence mode
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Hygienic areas (≥ 15 ACH) F7 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Carry/transport handle(s)
  Trestle rollers/ fixed castors
  Non-marking rubber wheels/rollers
  Foot
  Protective bar at the control panel
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame

 standard equipment

 optionally available

 not available

Tower version

Technical data
General information
  Article number 1.580.010.145
Dust class
  as per DIN EN 1822 (ISO 45H filter ISO 29463) H14
  as per DIN EN 779:2002 F7
Air flow rate
  Max. air volume flow [m³/h] 2,100
  Suitable for rooms sized up to [m²/m³] with H14 filter class 80 m² /200 m³
  Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] 1,200
  Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h]] 1,800
Electrical values
  Mains connection 220 - 240 V, 50/60 Hz
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Nominal current consumption [A] 3.5
  Recommended fusing [A] 6
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  Depending on the configuration (sound protection caps, FlowExtender) 29 - 50 dB(A)
Fan
  Radial
  axial
  stages 7
Safety feature
  Protection class IP20
Dimensions
  Length (packaging excluded) [mm] 506
  Width (packaging excluded) [mm] 523
  Height (packaging excluded) [mm] 1,100
Weight
  (packaging excluded) [kg] 84
Equipment, features and functions
Equipment
  Touchscreen
  Usage-related, sensor-controlled filter change indication of the F7 prefilter
  Usage-related, sensor-controlled filter change indication of the H14 main filter
  FlowMatic control
  Timer switch for the device is flexibly adjustable
  Key lock
  Update of the control software via USB flash drive
  Operating hours counter
  Language setting
  Silence mode
  sound protection hood
  Flowstop shutters
  Hose adapter
  Manipulation protection
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Hygienic areas (≥ 15 ACH) F7 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Carry/transport handle(s)
  Trestle rollers/ fixed castors
  Non-marking rubber wheels/rollers
  Foot
  Protective bar at the control panel
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame

 standard equipment

 optionally available

 not available

Techn. data TAC ECO

Mobile version

Technical data
General information
  Article number 1.580.001.140
Dust class
  as per DIN EN 1822 (ISO 45H filter ISO 29463) H14
  as per DIN EN 779:2002 G4 Z-line
Air flow rate
  Suitable for rooms sized up to [m²/m³] 80 m² /200 m³
  Max. air volume flow [m³/h] 1,600
  Recommended amount of air for standard filter with filter class H14 ≤ [m³/h] 1,000
  Recommended amount of air for standard filter with filter class H13 ≤ [m³/h] 1,600
Electrical values
  Mains connection 220 - 240 V, 50/60 Hz
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Nominal current consumption [A] 3.5
  Recommended fusing [A] 6
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  Depending on the configuration (sound protection caps, FlowExtender) 29 - 50 dB(A)
Fan
  Radial
  axial
  stages 6
Safety feature
  Protection class IP20
Dimensions
  Length (packaging excluded) [mm] 690
  Width (packaging excluded) [mm] 610
  Height (packaging excluded) [mm] 1,130
Weight
  (packaging excluded) [kg] 84
Equipment, features and functions
Equipment
  Manual control panel
  Usage-related, sensor-controlled filter change indication of the G4 prefilter
  Usage-related, sensor-controlled filter change indication of the H14 main filter
  Silence mode
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Hygienic areas (≥ 15 ACH) G4 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Carry/transport handle(s)
  Trestle rollers/ fixed castors
  Non-marking rubber wheels/rollers
  Foot
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame

 standard equipment

 optionally available

 not available

Tower version

Technical data
General information
  Article number 1.580.010.140
Dust class
  as per DIN EN 1822 (ISO 45H filter ISO 29463) H14
  as per DIN EN 779:2002 G4 Z-line
Air flow rate
  Suitable for rooms sized up to [m²/m³] 80 m² /200 m³
  Max. air volume flow [m³/h] 1,600
  Recommended amount of air for standard filter with filter class H14 ≤ [m³/h] 1,000
  Recommended amount of air for standard filter with filter class H13 ≤ [m³/h] 1,600
Electrical values
  Mains connection 220 - 240 V, 50/60 Hz
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Nominal current consumption [A] 3.5
  Recommended fusing [A] 6
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  Depending on the configuration (sound protection caps, FlowExtender) 29 - 50 dB(A)
Fan
  Radial
  axial
  stages 6
Safety feature
  Protection class IP20
Dimensions
  Length (packaging excluded) [mm] 506
  Width (packaging excluded) [mm] 523
  Height (packaging excluded) [mm] 1,100
Weight
  (packaging excluded) [kg] 84
Equipment, features and functions
Equipment
  Manual control panel
  Usage-related, sensor-controlled filter change indication of the G4 prefilter
  Usage-related, sensor-controlled filter change indication of the H14 main filter
  Silence mode
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Hygienic areas (≥ 15 ACH) G4 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Carry/transport handle(s)
  Trestle rollers/ fixed castors
  Non-marking rubber wheels/rollers
  Foot
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame

 standard equipment

 optionally available

 not available

Techn. data TAC BASIC

Technical data
General information
  Article number 1.580.001.139
Dust class
  as per DIN EN 1822 (ISO 45H filter ISO 29463) H14
  as per DIN EN 779:2002 G4 Z-line
Air flow rate
  Suitable for rooms sized up to [m²/m³] 80 m² /200 m³
  Max. air volume flow [m³/h] 1,600
  Recommended amount of air for standard filter with filter class H14 ≤ [m³/h] 1,000
  Recommended amount of air for standard filter with filter class H13 ≤ [m³/h] 1,600
Electrical values
  Mains connection 220 - 240 V, 50/60 Hz
  Power input [kW] 0.75
  Power consumption without thermal decontamination at 900 m³ / h air volume [kW] 0.16
  Recommended fusing [A] 6
Electric connection
  Connection plug CEE 7/7, H07RN-F
  Cable length [m] 4
Sound values
  Depending on the configuration (sound protection caps, FlowExtender) 31 - 50 db(A)
Fan
  Radial
  axial
  stages 6
Safety feature
  Protection class IP20
Dimensions
  Length (packaging excluded) [mm] 506
  Width (packaging excluded) [mm] 523
  Height (packaging excluded) [mm] 1,100
Weight
  (packaging excluded) [kg] 85
Equipment, features and functions
Equipment
  Manual control panel
  Silence mode
Filter
  combination Hygienic areas (≥ 15 ACH) G4 + H14
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 107
Mobility
  Swivel casters with parking brakes
  Feet

 standard equipment

 optionally available

 not available

Accessories

Loading...

Alternative products

Loading...

Seminars

Downloads

Loading...

Brochures

Loading...

Specification texts

Loading...

Videos