Effective virus air purification: Model variants and special solutions
Professional Trotec solutions for virus filtration and air pollution control
No other method than the HEPA high-performance filter technology provides "as much clean air for quickly diluting the aerosol clouds" with increased safety for the optimum price/clean air ratio!
To ensure that you're always provided with the precisely-tailored Trotec solution for effective virus filtration of the room air, exactly adapted to your individual safety requirement, in addition to the high-performance air purifier TAC V+ our range of products contains further model variants and special solutions.
To help you integrate the TAC V+ into the respective application environment, in addition to the standard colour yellow, this device is also available painted in the colours basalt grey, white or bronze.
Moreover, a stainless steel version is available for the use in hygiene-sensitive areas – and for virus air filtration in large halls we can offer you the special model TAC V+ Dual for wall or ceiling mounting, which blows out clean air to both sides.
100 % TAC V+ on the outside, modified to meet your requirements on the inside: model variants TAC M and TAC ECO
The model variants TAC M and TAC ECO are the perfect blend of the scientifically confirmed effective H14 HEPA virus filtration of the TAC V+ and your individual economic requirements, without having to forego any basic equipment features of the high-performance air purifier TAC V+.
The criteria for an effective virus air cleaner required by science are:
- The device must have a sufficiently large volumetric flow. at least six times the room volume per hour
- The device must be technically capable of removing 99.995 % of the viruses in the course of one air cycle, as can be ensured by an H14 HEPA filter complying with EN 1822
- The device must be quiet so that it does not disturb people inside the room, otherwise there is a risk of the device being switched off by the user
All these criteria are fully met not only by the TAC V+, but also by the TAC M and TAC ECO. This is why the air cleaners TAC M and TAC ECO are our best recommendation if you want to do without the full equipment of the TAC V+, but not without effective H14 HEPA virus filtration from Trotec "made in Germany".
Since the high-performance air purifiers TAC M and TAC ECO do not have a function for thermal decontamination and filter regeneration, they can also be used in areas which, due to electrical protection, only permit automated thermal decontamination to a limited extent. Consequently, the devices come without the added value of thermal room decontamination – maximum hygiene and safety –, which is offered by the TAC V+ through cyclic heat inactivation and thermal filter self-cleaning for longer filter lifetimes.
TAC M – TAC V+-like virus-filtered clean air
Being equipped with a programmable touch display incl. USB update function just like the TAC V+, the TAC M offers you convenient configuration options. Furthermore, you also benefit from the integrated FlowMatic control for a constant air volume flow at any power level with the TAC M. On request, the TAC M can be ordered in all colours available for the TAC V+.
TAC ECO – virus-filtered clean air, manually adjusted
The TAC ECO is the perfect reduction of the TAC V+ to its essential virus filter qualities with an H14 HEPA filter standard according to EN 1822. Once manually configured, the TAC ECO, too, will automatically make you benefit from virus-filtered clean air in your rooms. The TAC ECO is only available in light grey.
PRODUCT BROCHURE
The solution against aerosols, viruses and bacteria in the room air. Scientifically proven effectiveness, functional principle, installation tips, performance data, model variants - all relevant information about our high-performance air purifiers TAC V + / TAC M / TAC ECO / TAC XT can also be found in the product brochure. Download the PDF directly here.
Multi air handler TAC XT
For expanded fields of application of the TAC V+ beyond air pollution control, the multi air handler TAC XT was developed.
The multi air handler TAC XT is based on the same assembly as the TAC V+, which is why it is provided with an identical HEPA air purification function with filter class H14 and a filter efficiency of 99.995 %.
In addition, the multi air handler TAC XT can also be used for combined room heating as well as thermal pest control and thermal decontamination of viruses, for example for decontamination of sanitary facilities, dressing rooms, etc. during the night, or for the flexible, reliable decontamination of respiratory masks and disposable PSA equipment for multiple use.
Possible applications and equipment differences of TAC high-performance air purifiers at a glance
Trotec high-performance air purifiers with HEPA H14 suitability in compliance with EN 1822 (corresponds to ISO 45 H according to ISO 29463) | ![]() |
![]() |
![]() |
![]() |
![]() |
---|---|---|---|---|---|
TAC XT | TAC V+ | TAC M | TAC ECO | TAC BASIC | |
Use for high-performance H14 HEPA air purification as per EN 1822 | ✓ | ✓ | ✓ | ✓ | ✓ |
Usage-related filter change indicator for prefilter and HEPA filter | ✓ | ✓ | ✓ | ✓ | – |
Mobile carriage design | ✓ | ✓ | ✓ | ✓ | – |
FlowMatic volumetric flow control | ✓ | ✓ | ✓ | – | – |
Programmable touch display updateable via USB | ✓ | ✓ | ✓ | – | – |
Thermal filter decontamination and filter regeneration | ✓ | ✓ | – | – | – |
Use for room heating, tent heating (heating capacity 18/27 kW) | ✓ | – | – | – | – |
Use for thermal decontamination of rooms and objects | ✓ | – | – | – | – |
Use for thermal disinfestation | ✓ | – | – | – | – |
Trotec high-performance air purifiers with HEPA H14 suitability in compliance with EN 1822 (corresponds to ISO 45 H according to ISO 29463) | TAC XT | TAC V+ | TAC M | TAC ECO | TAC BASIC |
---|---|---|---|---|---|
Use for high-performance H14 HEPA air purification as per EN 1822 | ✓ | ✓ | ✓ | ✓ | ✓ |
Usage-related filter change indicator for prefilter and HEPA filter | ✓ | ✓ | ✓ | ✓ | – |
Mobile carriage design | ✓ | ✓ | ✓ | ✓ | – |
FlowMatic volumetric flow control | ✓ | ✓ | ✓ | – | – |
Programmable touch display updateable via USB | ✓ | ✓ | ✓ | – | – |
Thermal filter decontamination and filter regeneration | ✓ | ✓ | – | – | – |
Use for room heating, tent heating (heating capacity 18/27 kW) | ✓ | – | – | – | – |
Use for thermal decontamination of rooms and objects | ✓ | – | – | – | – |
Use for thermal disinfestation | ✓ | – | – | – | – |
TAC high-performance air purifiers – show more technical data
TAC high-performance air purifiers – more technical data at a glance | ![]() |
![]() |
![]() |
![]() |
![]() |
---|---|---|---|---|---|
TAC XT | TAC V+ | TAC M | TAC ECO | TAC BASIC | |
Max. air flow rate heating (without HEPA filter) | 2,500 m³/h | - | - | - | - |
Max. air volume flow for the respective filter class |
with standard HighFlow H14 HEPA Heat Resistant filter: H14 ≤ 1,200 m³/h, H13 ≤ 1,800 m³/h, with optional Ultra-HighFlow H14 HEPA filter: H14 ≤ 2,000 m³/h, H13 ≤ 2,200 m³/h |
H14 ≤ 1,000 m³/h H13 ≤ 1,600 m³/h |
|||
Prefilter | F7 (EN 779:2002), ePM10 85 % (ISO 16890) | G4 Z-line (EN 779:2002) |
|||
High-temperature particulate air filter |
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822 Fully encapsulated H14 HighFlow metal lamellae high-temperature filter 'made in Germany' (optional also as Ultra-HighFlow filter). Each filter is tested and certified individually. |
TROTEC HEPA H14, EN 1822 (standard minipleat) Each filter is tested and certified individually. |
|||
Filter change interval |
approx. 2 to 3 years (depending on the application and with regular thermal decontamination) |
approx. 1 to 2 years (depending on the application) |
approx. 1 year (depending on the application) |
||
Filter change indication | Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter | - | |||
FlowMatic control |
Constant clean air volume flow, constant circulation rates in each power level also with increasing filter contamination. Air volume freely adjustable in m³. |
– | |||
Safety and filter hygiene: Thermal decontamination and filter regeneration at approx. 100 °C. 15 min. heating-up phase / 15 min. decon phase (altogether 30 min.) |
Time freely programmable, the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours. Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required. Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination. |
No thermal decontamination and reconditioning of the filter |
|||
Mains connection (connector plug) | 380–480 V 50 / 60 Hz (CEE 32 A) | 220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F) | |||
ø power consumption |
Air purification: 0.16 kW*, 2.5 kW (short-term peak load, e.g. once a week during thermal decontamination)
heating: max. 27 kW |
0.16 kW*, 2.5 kW (short-term peak load, e.g. once a week during thermal decontamination) |
0.16 kW* | ||
Exemplary total energy consumption (with 900 m³/h air volume) |
Without thermal decontamination approx. 1.6 kWh per day / approx. 35 kWh per month* With thermal decontamination approx. 1.8 kWh per day / approx. 39 kWh per month* and thermal decontamination once a week |
approx. 1.6 kWh per day / approx. 35 kWh per month* |
|||
Control panel | Programmable, USB updateable touch display with PIN-protected lock function | Manual control panel (6-step switch) | |||
Weight | 96 kg (incl. filter) | 89 kg (incl. filter) | 84 kg (incl. filter) | 85 kg (incl. filter) | |
* for a 5-day week with 10 h operating time per day and 900 m³ air volume |
TAC XT |
Max. air flow rate heating (without HEPA filter) |
2,500 m³/h |
Max. air volume flow for the respective filter class |
with standard HighFlow H14 HEPA Heat Resistant filter: H14 ≤ 1,200 m³/h, H13 ≤ 1,800 m³/h, with optional Ultra-HighFlow H14 HEPA filter: H14 ≤ 2,000 m³/h, H13 ≤ 2,200 m³/h |
Prefilter |
F7 (EN 779:2002), ePM10 85 % (ISO 16890) |
High-temperature particulate air filter |
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822 Fully encapsulated H14 HighFlow metal lamellae high-temperature filter 'made in Germany' (optional also as Ultra-HighFlow filter). Each filter is tested and certified individually. |
Filter change interval |
Approx. 2 to 3 years (depending on the application and with regular thermal decontamination) |
Filter change indication |
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter |
FlowMatic control |
Constant clean air volume flow, constant circulation rates in each power level also with increasing filter contamination. Air volume freely adjustable in m³. |
Safety and filter hygiene: Thermal decontamination and filter regeneration at approx. 100 °C. 15 min. heating-up phase / 15 min. decon phase (altogether 30 min.) |
Time freely programmable, the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours. Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required. Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination. |
Mains connection (connector plug) |
380–480 V 50 / 60 Hz (CEE 32 A) |
ø power consumption |
Air purification: 0.16 kW*, 2.5 kW (short-term peak load, e.g. once a week during thermal decontamination)
heating: max. 27 kW |
Exemplary total energy consumption (with 900 m³/h air volume) |
Without thermal decontamination approx. 1.6 kWh per day / approx. 35 kWh per month* With thermal decontamination approx. 1.8 kWh per day / approx. 39 kWh per month* and thermal decontamination once a week |
Control panel |
Programmable, USB updateable touch display with PIN-protected lock function |
Weight |
96 kg (incl. filter) |
* for a 5-day week with 10 h operating time per day and 900 m³ air volume |
TAC V+ |
Max. air flow rate heating (without HEPA filter) |
- |
Max. air volume flow for the respective filter class |
with standard HighFlow H14 HEPA Heat Resistant filter: H14 ≤ 1,200 m³/h, H13 ≤ 1,800 m³/h, with optional Ultra-HighFlow H14 HEPA filter: H14 ≤ 2,000 m³/h, H13 ≤ 2,200 m³/h |
Prefilter |
F7 (EN 779:2002), ePM10 85 % (ISO 16890) |
High-temperature particulate air filter |
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822 Fully encapsulated H14 HighFlow metal lamellae high-temperature filter 'made in Germany' (optional also as Ultra-HighFlow filter). Each filter is tested and certified individually. |
Filter change interval |
Approx. 2 to 3 years (depending on the application and with regular thermal decontamination) |
Filter change indication |
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter |
FlowMatic control |
Constant clean air volume flow, constant circulation rates in each power level also with increasing filter contamination. Air volume freely adjustable in m³. |
Safety and filter hygiene: Thermal decontamination and filter regeneration at approx. 100 °C. 15 min. heating-up phase / 15 min. decon phase (altogether 30 min.) |
Time freely programmable, the thermal decontamination and filter regeneration process takes place fully automatically, usually once a week at night or outside business or teaching hours. Thermal decontamination and filter regeneration can be switched off temporarily or even constantly as required. Due to the short treatment duration (15 min.) and the low energy input (altogether approx. 1.0 kWh per cycle), the room temperature does not increase by thermal decontamination. |
Mains connection (connector plug) |
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F) |
ø power consumption |
0.16 kW*, 2.5 kW (short-term peak load, e.g. once a week during thermal decontamination) |
Exemplary total energy consumption (with 900 m³/h air volume) |
Without thermal decontamination approx. 1.6 kWh per day / approx. 35 kWh per month* With thermal decontamination approx. 1.8 kWh per day / approx. 39 kWh per month* and thermal decontamination once a week |
Control panel |
Programmable, USB updateable touch display with PIN-protected lock function |
Weight |
89 kg (incl. filter) |
* for a 5-day week with 10 h operating time per day and 900 m³ air volume |
TAC M |
Max. air flow rate heating (without HEPA filter) |
- |
Max. air volume flow for the respective filter class |
with standard HighFlow H14 HEPA Heat Resistant filter: H14 ≤ 1,200 m³/h, H13 ≤ 1,800 m³/h, with optional Ultra-HighFlow H14 HEPA filter: H14 ≤ 2,000 m³/h, H13 ≤ 2,200 m³/h |
Prefilter |
F7 (EN 779:2002), ePM10 85 % (ISO 16890) |
High-temperature particulate air filter |
TROTEC HEPA H14 HighFlow Heat Resistant filter, EN 1822 Fully encapsulated H14 HighFlow metal lamellae high-temperature filter 'made in Germany' (optional also as Ultra-HighFlow filter). Each filter is tested and certified individually. |
Filter change interval |
Approx. 1 to 2 years (depending on the application) |
Filter change indication |
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter |
FlowMatic control |
Constant clean air volume flow, constant circulation rates in each power level also with increasing filter contamination. Air volume freely adjustable in m³. |
Safety and filter hygiene: Thermal decontamination and filter regeneration at approx. 100 °C. 15 min. heating-up phase / 15 min. decon phase (altogether 30 min.) |
No thermal decontamination and reconditioning of the filter |
Mains connection (connector plug) |
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F) |
ø power consumption |
0.16 kW* |
Exemplary total energy consumption (with 900 m³/h air volume) |
approx. 1.6 kWh per day / approx. 35 kWh per month* |
Control panel |
Programmable, USB updateable touch display with PIN-protected lock function |
Weight |
84 kg (incl. filter) |
* for a 5-day week with 10 h operating time per day and 900 m³ air volume |
TAC ECO |
Max. air flow rate heating (without HEPA filter) |
- |
Max. air volume flow for the respective filter class |
H14 ≤ 1,000 m³/h H13 ≤ 1,600 m³/h |
Prefilter |
G4 Z-line (EN 779:2002) |
High-temperature particulate air filter |
TROTEC HEPA H14, EN 1822 (standard minipleat) Each filter is tested and certified individually. |
Filter change interval |
Approx. 1 year (depending on the application) |
Filter change indication |
Usage-related, sensor-controlled filter change indicator for prefilter and HEPA filter |
FlowMatic control |
– |
Safety and filter hygiene: Thermal decontamination and filter regeneration at approx. 100 °C. 15 min. heating-up phase / 15 min. decon phase (altogether 30 min.) |
No thermal decontamination and reconditioning of the filter |
Mains connection (connector plug) |
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F) |
ø power consumption |
0.16 kW* |
Exemplary total energy consumption (with 900 m³/h air volume) |
approx. 1.6 kWh per day / approx. 35 kWh per month* |
Control panel |
Manual control panel (6-step switch) |
Weight |
84 kg (incl. filter) |
* for a 5-day week with 10 h operating time per day and 900 m³ air volume |
TAC BASIC |
Max. air flow rate heating (without HEPA filter) |
- |
Max. air volume flow for the respective filter class |
H14 ≤ 1,000 m³/h H13 ≤ 1,600 m³/h |
Prefilter |
G4 Z-line (EN 779:2002) |
High-temperature particulate air filter |
TROTEC HEPA H14, EN 1822 (standard minipleat) Each filter is tested and certified individually. |
Filter change interval |
Approx. 1 year (depending on the application) |
Filter change indication |
– |
FlowMatic control |
– |
Safety and filter hygiene: Thermal decontamination and filter regeneration at approx. 100 °C. 15 min. heating-up phase / 15 min. decon phase (altogether 30 min.) |
No thermal decontamination and reconditioning of the filter |
Mains connection (connector plug) |
220–240 V 50 / 60 Hz (CEE 7/7, H07RN-F) |
ø power consumption |
0.16 kW* |
Exemplary total energy consumption (with 900 m³/h air volume) |
approx. 1.6 kWh per day / approx. 35 kWh per month* |
Control panel |
Manual control panel (6-step switch) |
Weight |
85 kg (incl. filter) |
* for a 5-day week with 10 h operating time per day and 900 m³ air volume |
Available colour variants
TAC XT |
Available colour versions |
Yellow |
Also available as stainless steel version |
✓ |
TAC V+ |
Available colour versions |
Yellow, basalt grey, white, bronze |
Also available as stainless steel version |
✓ |
TAC M |
Available colour versions |
Yellow, basalt grey, white, bronze |
Also available as stainless steel version |
– |
TAC ECO |
Available colour versions |
Light grey |
Also available as stainless steel version |
– |
TAC BASIC |
Available colour versions |
Light grey |
Also available as stainless steel version |
– |
Optional accessories and equipment options for the TAC high-performance air purifiers TAC V+, TAC M and TAC ECO
Ultra-HighFlow HEPA H14 filter
Only for TAC XT, TAC V+ and TAC M: Compared to the standard HighFlow HEPA H14 filter, the more powerful Ultra-HighFlow HEPA H14 filter allows for a 66 % higher clean air flow rate combined with a noise emission reduce by up to 8 % and an energy consumption that is lower by 30 %.
Stainless steel version for hygiene-sensitive areas
The high-performance air purifier TAC V+ as well as the multi air handler TAC XT are optionally also available in stainless steel design, which is ideally suited for the use in areas with specific hygiene requirements or especially reactive atmospheres.
The stainless steel housing is easy to clean and manufactured of the material 1.4301, which features a very high corrosion resistance and which is particularly resistant to various chemical solutions.
TAC V+ Dual for virus filtration in large halls
For virus-free air purification of even very large hall areas we recommend using the TAC V+ Dual. This special model that blows out clean air on both sides offers you all advantages of the TAC V+ basic model, including the unique thermal filter decontamination and regeneration function.
With its high-pressure fan and the special filter equipment, the effectiveness of which has been proven, the Dual design, which draws in air at the floor side and blows it out on two sides, makes it possible to extensively flush even spacious hall areas with virus-free, filtered clean air.
C profiles integrated on both sides allow you to flexibly mount the TAC V+ Dual on the ceiling or wall, in the process of which you can also remove the control panel of the TAC V+ from the unit and attach it near the floor by cable, for example on mounting columns or the hall wall, also making it possible to easily control the high-performance air purifier from a distance even if the TAC V+ Dual has been mounted at a great height.
With the stainless steel version you can even use the TAC V+ Dual, which is available with a variety of clean air capacities on request, in hygiene-sensitive areas without any restrictions. Just contact our experts, we would be happy to advise you personally.
Learn more about the technical possibilities of virus air filtration
You want to know which technical aids offer effective protection against viruses in the room air? Do you have any questions with regard to the different cleaning methods offered on the market, their functional principle and their suitability for virus filtration? Visit our air cleaner-FAQ for virus filtration – Here you'll find answers to all of your questions with regard to air purification, virus filtration, standards as well as filter classes and of course the high-performance air purifier TAC V+ ...
Work more securely with our TAC business leasing from €49 per month*
More freedom through flexible financing at top conditions is made possible by our TAC business leasing with instalments from €49*. We would be happy to advise you personally and calculate the best leasing offer for you: +49 2452-962-730 * plus VAT with 0 % down payment. For traders only
* We will automatically check whether there are federal or state funding programmes available for your application area.
Plan flexibly with the TAC business rental from €15 per day*
Plannable health protection whenever and for as long as you want it. Rent our TAC high-performance air purifiers by the day, over the weekend or for the long term with instalments from €15. We would be happy to advise you personally: +49 2452-962-730 * plus VAT with 0 % down payment. For traders only
Buy

Room air purifier TAC V+ in White/black + sound insulation hood
The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.
3,816.12 £ incl. VAT Show net price (VAT not included)

Room air purifier TAC V+ in bronze/black + sound insulation hood
The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.
3,816.12 £ incl. VAT Show net price (VAT not included)

Room air purifier TAC V+ in grey/black + sound insulation hood
The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.
3,816.12 £ incl. VAT Show net price (VAT not included)

Room air purifier TAC V+ + sound insulation hood
The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% '''decontaminates''' the filter again.
3,816.12 £ incl. VAT Show net price (VAT not included)

Room air purifier TAC V+ stainless steel + sound insulation hood
The TAC V+ has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus "decontaminates" the filter 100%. Now with matching sound insulation hood.
4,362.06 £ incl. VAT Show net price (VAT not included)

Room air purifier M in basalt grey/black + sound insulation hood
The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.
You save: 328.14 £
3,466.39 £
3,138.25 £
incl. VAT
Show net price (VAT not included)

Room air purifier M in bronze/black + sound insulation hood
The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.
You save: 109.19 £
3,466.39 £
3,357.20 £
incl. VAT
Show net price (VAT not included)

Room air purifier M in white/black + sound insulation hood
The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.
You save: 305.40 £
3,466.39 £
3,160.99 £
incl. VAT
Show net price (VAT not included)

Room air purifier M + sound insulation hood
The TAC M high-performance air purifier ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.
You save: 109.19 £
3,466.39 £
3,357.20 £
incl. VAT
Show net price (VAT not included)

Room air purifier TAC ECO + sound insulation hood
The high-performance air purifier TAC ECO ensures virus-, bacteria- and aerosol-free room air. Effective high-performance filtration with the highest HEPA filter class certified according to EN 1822.
You save: 109.19 £
2,887.69 £
2,778.50 £
incl. VAT
Show net price (VAT not included)
Techn. data TAC V+
Technical data | ||
---|---|---|
General information | ||
Article number | 1.580.000.150 | |
Dust class | ||
(as per DIN EN 1822 (ISO 45H filter ISO 29463) | H14 | |
(as per DIN EN 779:2002) | F7 | |
Air flow rate | ||
Geeignet für Räume bis [m²/m³] bei Filterklasse H14 | 80 m² /200 m³ | |
Max. air volume flow [m³/h] | 2,200 | |
Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] | 1,200 | |
Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h]] | 1,800 | |
Recommended amount of air for Ultra HighFlow filter with filter class H14 ≤ [m³/h] | 2,000 | |
Recommended amount of air for Ultra HighFlow filter with filter class H13 ≤ [m³/h] | 2,200 | |
Electrical values | ||
Mains connection | 220 - 240 V/50 - 60 Hz | |
Power consumption without thermal decontamination at 900 m³ / h air volume [kW] | 0.16 | |
Power consumption with thermal decontamination for 30 minutes [kW] | 2.5 | |
Nominal current consumption [A] | 11.3 | |
Recommended fusing [A] | 13 | |
Electric connection | ||
Connection plug | CEE 7/7, H07RN-F | |
Cable length [m] | 4 | |
Sound values | ||
with sound protection hood - Distance 1 m | 33 - 64 dB(A) | |
with sound protection hood and Ultra HighFlow filter - Distance 1 m | 33 - 62 dB(A) | |
Fan | ||
Radial | ||
axial | ||
stages | 7 | |
Dimensions | ||
Length (packaging excluded) [mm] | 690 | |
Width (packaging excluded) [mm] | 610 | |
Height (packaging excluded) [mm] | 1,300 | |
Weight | ||
(packaging excluded) [kg] | 89 |
Equipment, features and functions | ||
---|---|---|
Equipment | ||
Thermal filter decontamination | ||
Thermal filter regeneration | ||
Touchscreen | ||
Usage-related, sensor-controlled filter change indication of the F7 prefilter | ||
Usage-related, sensor-controlled filter change indication of the H14 main filter | ||
FlowMatic control | ||
Timer switch for the device is flexibly adjustable | ||
Timer switch for thermal decontamination is flexibly adjustable | ||
Operating hours counter | ||
Update der Steuerungssoftware per USB-Stick | ||
Sprachauswahl | ||
Key lock | ||
Silence Mode | ||
sound protection hood | ||
Flowstop shutters | ||
Hose adapter | ||
Manipulation protection | ||
Filter change indication | ||
Pre-filter | ||
Main filter | ||
Filter | ||
combination Hygienic areas (≥ 15 ACH) | F7 + H14 | |
Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] | 107 | |
Mobility | ||
Carry/transport handle(s) | ||
Trestle rollers/ fixed castors | ||
Non-marking rubber wheels/rollers | ||
Foot | ||
Schutzbügel am Bedientableau | ||
Full-rubber guide wheels | ||
Guiding wheels pneumatic tyres | ||
Stacking frame | ||
Forklift pockets | ||
Shock protection frame |
standard equipment
optionally available
not available
Techn. data TAC M
Technical data | ||
---|---|---|
General information | ||
Article number | 1.580.000.145 | |
Dust class | ||
(as per DIN EN 1822 (ISO 45H filter ISO 29463) | H14 | |
(as per DIN EN 779:2002) | F7 | |
Air flow rate | ||
Geeignet für Räume bis [m²/m³] bei Filterklasse H14 | 80 m² /200 m³ | |
Max. air volume flow [m³/h] | 2,200 | |
Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] | 1,200 | |
Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h]] | 1,800 | |
Recommended amount of air for Ultra HighFlow filter with filter class H14 ≤ [m³/h] | 2,000 | |
Recommended amount of air for Ultra HighFlow filter with filter class H13 ≤ [m³/h] | 2,200 | |
Electrical values | ||
Mains connection | 220 - 240 V/50 - 60 Hz | |
Power consumption without thermal decontamination at 900 m³ / h air volume [kW] | 0.16 | |
Nominal current consumption [A] | 3.5 | |
Recommended fusing [A] | 6 | |
Electric connection | ||
Connection plug | CEE 7/7, H07RN-F | |
Cable length [m] | 4 | |
Sound values | ||
with sound protection hood - Distance 1 m | 33 - 64 dB(A) | |
with sound protection hood and Ultra HighFlow filter - Distance 1 m | 33 - 62 dB(A) | |
Fan | ||
Radial | ||
axial | ||
stages | 7 | |
Dimensions | ||
Length (packaging excluded) [mm] | 690 | |
Width (packaging excluded) [mm] | 610 | |
Height (packaging excluded) [mm] | 1,300 | |
Weight | ||
(packaging excluded) [kg] | 84 |
Equipment, features and functions | ||
---|---|---|
Equipment | ||
Touchscreen | ||
Usage-related, sensor-controlled filter change indication of the F7 prefilter | ||
Usage-related, sensor-controlled filter change indication of the H14 main filter | ||
FlowMatic control | ||
Timer switch for the device is flexibly adjustable | ||
Key lock | ||
Update der Steuerungssoftware per USB-Stick | ||
Operating hours counter | ||
Sprachauswahl | ||
Silence Mode | ||
sound protection hood | ||
Flowstop shutters | ||
Hose adapter | ||
Manipulation protection | ||
Filter change indication | ||
Pre-filter | ||
Main filter | ||
Filter | ||
combination Hygienic areas (≥ 15 ACH) | F7 + H14 | |
Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] | 107 | |
Mobility | ||
Carry/transport handle(s) | ||
Trestle rollers/ fixed castors | ||
Non-marking rubber wheels/rollers | ||
Foot | ||
Schutzbügel am Bedientableau | ||
Full-rubber guide wheels | ||
Guiding wheels pneumatic tyres | ||
Stacking frame | ||
Forklift pockets | ||
Shock protection frame |
standard equipment
optionally available
not available
Techn. data TAC ECO
Technical data | ||
---|---|---|
General information | ||
Article number | 1.580.000.140 | |
Dust class | ||
(as per DIN EN 1822 (ISO 45H filter ISO 29463) | H14 | |
(as per DIN EN 779:2002) | G4 Z-line | |
Air flow rate | ||
Suitable for rooms sized up to [m²/m³] | 80 m² /200 m³ | |
Max. air volume flow [m³/h] | 1,800 | |
Recommended amount of air for standard filter with filter class H14 ≤ [m³/h] | 1,000 | |
Recommended amount of air for standard filter with filter class H13 ≤ [m³/h] | 1,600 | |
Electrical values | ||
Mains connection | 220 - 240 V/50 - 60 Hz | |
Power consumption without thermal decontamination at 900 m³ / h air volume [kW] | 0.16 | |
Nominal current consumption [A] | 3.5 | |
Recommended fusing [A] | 6 | |
Electric connection | ||
Connection plug | CEE 7/7, H07RN-F | |
Cable length [m] | 4 | |
Sound values | ||
with sound protection hood - Distance 1 m | 33 - 63 dB(A) | |
with sound protection hood and ECO-HighFlow-filter - Distance 1 m | 33 - 61 dB(A) | |
Fan | ||
Radial | ||
axial | ||
stages | 6 | |
Dimensions | ||
Length (packaging excluded) [mm] | 690 | |
Width (packaging excluded) [mm] | 610 | |
Height (packaging excluded) [mm] | 1,300 | |
Weight | ||
(packaging excluded) [kg] | 84 |
Equipment, features and functions | ||
---|---|---|
Equipment | ||
Manual control panel | ||
Usage-related, sensor-controlled filter change indication of the G4 prefilter | ||
Usage-related, sensor-controlled filter change indication of the H14 main filter | ||
Timer switch for the device is flexibly adjustable | ||
Silence Mode | ||
sound protection hood | ||
Flowstop shutters | ||
Hose adapter | ||
Manipulation protection | ||
Filter change indication | ||
Pre-filter | ||
Main filter | ||
Filter | ||
combination Hygienic areas (≥ 15 ACH) | G4 + H14 | |
Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] | 107 | |
Mobility | ||
Carry/transport handle(s) | ||
Trestle rollers/ fixed castors | ||
Non-marking rubber wheels/rollers | ||
Foot | ||
Full-rubber guide wheels | ||
Guiding wheels pneumatic tyres | ||
Stacking frame | ||
Forklift pockets | ||
Shock protection frame |