Heat with speed: heating gymnasiums
Mobile heating devices heat up sections of gyms and halls in a short time - the perfect temperature at the push of a button
Modern gyms are usually equipped with well-functioning heating systems. Ventilation systems as well as ceiling spots are among the most important equipment such a gym or event site should have. But when only a part of the gym is used for a sports class or a small group of people, it is inefficient to heat the entire sports complex. In these cases it is worth to have a mobile heating device at hand, which specifically heats only the cubic metres which are actually in use. The electric heating devices of the TEH series from Trotec provide warm air where it is needed, at the push of a button.
Particularly during the winter months it takes a lot of time to heat up an entire gym or event hall. The heating system has to be switched on well in advance in order to allow for the heat to spread. For an indoor tennis centre or a gym that is fully utilised throughout the day the efforts of heating it up are worthwhile. But what happens if only a small part of the gym is needed? For example, what if a triple multi-purpose hall is only used for a yoga course with a modest number of participants during a day? Or if only a small group of people meet at a communal or club room? In these cases, it is inefficient to heat up the entire complex: On the one hand, there is simply no need for most of the heat produced. On the other hand, additional staff is required to heat up the hall hours in advance.
Focussed heat
With an additional mobile heating system, you are optimally prepared. This system has to be put into operation only a few minutes before the course or event starts. At the push of a button, the defined area reaches the required temperature. In this field of application, the electric heaters of the TEH series from Trotec are reliable heat suppliers. No inlet or exhaust air openings are needed, since the models of the TEH series do not consume any oxygen. Therefore, they are particularly well suited for indoor use. The robust and technically sophisticated construction ensures a focussed flow of heated air and a high fan performance, making sure that the heat reaches exactly the area where it is needed.
Always the right model
Even the smallest version of the TEH electric heating devices, the TEH 20 T, comes with a decent performance. The compact heater manages a performance of 2.5 kW. It impresses with its infinitely variable thermostat control, ensuring that the heating elements only switch themselves on as needed in addition to the permanent fan according to precise temperature parameters. The more, the better? In this case we recommend the use of the professional electric heater TEH 100. Due to a fan performance of up to 1,440 m³/h and a heating capacity of 18 kW, it heats up even larger parts of a gym in next to no time.
All TEH electric heating devices guarantee one-hundred per cent Trotec quality in terms of development, design and production.
Your benefits:
- ready for use within a short time
- easy and flexible handling
- particularly durable
- focussed current of non-turbulent warm air
- space-saving storage due to multi-stack capability
- safe transport
- extremely low in maintenance
Make use of our best practice industrial services
You can count on our experts
In order to precisely calculate the demand in the industry and to develop tailor-made concepts for climate conditioning experienced climate specialists are needed. Rely on our team of experts as well as the industrial services: We analyse the individual requirement situation with you present on site, determine the specific demand for devices and develop a tailor-made project solution right up to the exact positioning of the devices.
Just give us a call at +49 2452 962-777 – our industry consultants will be pleased to help you personally and provide information regarding our best practice industrial services. Or send a request indicating your personal requirements directly to our industry experts. We will answer promptly!
Since every industrial undertaking has characteristic process flows, installations and facilities, every air treatment solution demands case-specific device configurations. All in all, the combined effects of air currents, humidity conditions and temperature fluctuations are often hard to calculate on a purely theoretical basis, e.g. in airlock areas or on conveying paths. The consequence: Unnecessary additional costs due to an overestimated demand or – even worse – solutions not working sufficiently in real life.
Heating gymnasiums
Further application examples for heating
Products ‑ HighPerformance
Dehumidification
TTK 75 ECO
20 l/24h
260
TTK 170 ECO
52 l/24h
350
TTK 171 ECO
52 l/24h
450
TTK Qube
20 l/24h
283
TTK 125 S
32 l/24h
250
TTK 175 S
50 l/24h
580
TTK 355 S
70 l/24h
490
TTK 655 S
100 l/24h
925
TTK 105 S
30 l/24h
173
TTK 140 S
28.5 l/24h
580
TTK 170 S
35.5 l/24h
580
TTK 350 S
63.5 l/24h
490
TTK 650 S
88 l/24h
925
TTR 200
0.35 kg/h
80 m³/h
TTR 300
0.7 kg/h
200 m³/h
TTR 400
1.2 kg/h
350 m³/h
TTR 400 D
1.6 kg/h
350 m³/h
TTR 500 D
2.2 kg/h
480 m³/h
TTR 160
0.5 kg/h
155 m³/h
TTR 250
1.1 kg/h
250 m³/h
DH 60
104 l/24h
1,165
DH 160
85 l/24h
2,200
DH 310
500 l/24h
4,600
Heating
TEH 200
40 kW
TEH 300
80 kW
TEH 400
120 kW
TEH 30 T
3.3 kW
300
TEH 70
6 - 9 - 12 kW
1,258
TEH 100
9 - 13.5 - 18 kW
1,785
TDS 10
0 - 1 - 2 kW
186 m³/h
TDS 10 M
1 - 2 kW
100 m³/h
TDS 20
1.65 - 3.3 kW
335
TDS 30
2.75 - 5.5 kW
458 m³/h
TDS 50
4.5 - 9 kW
708 m³/h
TDS 75
5 - 10 -15 kW
1,293 m³/h
TDS 100
11 - 22 kW
1,632 m³/h
TDS 120
15 - 30 kW
1,980
TDS 20 R
3 kW
411 m³/h
TDS 30 R
2.5 - 5 kW
580 m³/h
TDS 50 R
4.5 - 9 kW
844 m³/h
TDE 25
3 kW
206
TDE 65
0,1 - 6 - 9 - 12 kW
1,094
TDE 95
0,1 - 9 - 13,5 - 18 kW
1,074
IDS 20 D
20 kW
350
IDS 30 D
38.4 kW
605
IDS 100
117 kW
5,550
IDS 9500
225 kW
12,800
TIH 650+
650 W
1,370 x 625 mm
Air conditioning
Products ‑ HomeComfort
Dehumidification
TTK 26 E
10 l/24h
80
TTK 27 HEPA
12 l/24h
90
TTK 30 E
12 l/24h
120
TTK 32 E
14 l/24h
118
TTK 33 E
14 l/24h
80
TTK 52 E
16 l/24h
110
TTK 53 E
16 l/24h
195
TTK 54 E
18 l/24h
150
TTK 60 E
18 l/24h
100 m³/h
TTK 64 HEPA
24 l/24h
130
TTK 66 E
24 l/24h
168
TTK 68 E
20 l/24h
130
TTK 70 HEPA
20 l/24h
140
TTK 71 E
24 l/24h
180
TTK 72 E
24 l/24h
195
TTK 75 E
20 l/24h
150
TTK 90 E
30 l/24h
173
TTK 95 E
30 l/24h
185
TTK 96 E
30 l/24h
191
TTK 99 HEPA
31 l/24h
170
TTK 100 E
30 l/24h
215
TTK 120 S
35 l/24h
510 m³/h
TTK 120 E
30 l/24h
240
TTK 122 E
40 l/24h
240
TTK 127 E
50 l/24h
353