Advice for private customers: +49 2452 962-450

Advice for business customers: +49 2452 962-400

Mon - Fri: 9:00 - 17:00 (CET)

LD6000 H2 Hydrogen Sensor for trace gas detection
  1. Products & Services
  2. Measuring devices
  3. Leak detection
  4. Combination measuring devices for leak detection
  5. LD6000 combination detector for leak detection
  6. Hydrogen sensor LD6000 H2

LD6000 H2 Hydrogen Sensor for trace gas detection

For precise leak detection and tightness tests on sealing sheets, lines and containers

H2 hydrogen sensor - accessory for our LD6000

Using the optionally available hydrogen sensor LD6000 H2, the LD6000 is excellently suited for leak detection with 95/5 forming gas, which is composed of 95% nitrogen and 5% hydrogen.

Owing to its specific structure, hydrogen permeates almost all materials such as soil, concrete or tiles and can then be easily and precisely located on the surface using the hydrogen sensor connected to the LD6000.

The LD6000 indicates the exact concentration of hydrogen. Limit values can be freely adjusted and when exceeded, cause an acoustic and visual signal.

Forming gas of the type 95/5 is neither toxic nor combustible. Therefore, the application for leak detection even in sensitive surrounding areas is generally harmless.

Besides the compact hand sensor, an additional ground sensor with integrated suction pump is available for the detection of even the smallest of trace gas concentrations.

The ground sensor is especially suited for tightness tests or leak detection of green roofs, deep ground wires covered with soil and even asphalt covers etc.

Trace gas hydrogen:

Hydrogen serves as trace gas for leak detection, because it is the lightest of all gases.

Owing to its specific structure, hydrogen very quickly permeates all materials such as soil, concrete, tiles etc.

Upon emerging, the LD6000 H2 sensor registers the hydrogen, which e.g. in the usual 95/5 % forming gas is used as tracer gas for leakages, with a sensitivity level of 1 ppm.

The LD6000 H2 pump kit is as standard already integrated in the hydrogen ground sensor LD6000 H2 (art. no. 3.110.008.020), can however also be ordered individually in order to upgrade older LD6000 H2 ground sensors without integrated pump already in stock.

LD 6000 H2 Hand Sensor

LD 6000 H2 Hand Sensor

  • Response sensitivity: 1 ppm H₂
  • Measuring range: Starting at 10 ppm H₂
  • Resolution: 1 ppm H₂
  • Reaction time: 0.5 s
  • Model: Hand sensor with flexible swan-neck (length 50 cm) and approx. 160 cm long connecting lead for LD6000
  • Temperature conditions During operation: -10 °C to +60 °C, Storage -20 °C to +60 °C
LD6000 H2-Ground Sensor incl. Pump kit

LD6000 H2-Ground Sensor incl. Pump kit

  • Power supply: 6 V
  • Pump performance: 1.5 litres/minute
  • Power input: approx. 45 mA at free flow
  • Temperature conditions: -10°C to 40°C
  • Dimensions: 960 x 95 x 95 mm
  • Weight: 1.1 kg

Pipe location mode

Leitungsortungsmodus

This mode serves to localize pressurized water lines especially those made of plastic, treated with ultrasound by pulse generator LD-PULS.

More information on LD-PULS...

Leak detection and acoustic pipe location

Spurengasdetektion

Whether for line routing, leak encircling or pinpoint location – the advanced LD6000 and high-quality microphones of German manufacturing enable the capturing, signal processing and display of even the teensiest leakage sounds in as yet unknown dimensions.

LD6000 combination detector

LD6000 H2 Hand Sensor

LD 6000 H2 Hand Sensor show in Trotec online shop
Technical data
General information
  Article number 3.110.008.011
H2gas [ppm]
  Min. measuring range | H2 gas [ppm] 10
  Max. measuring range | H2 gas [ppm] 20,000
  Resolution | H2 gas [ppm] 1
  Response sensitivity | H2 gas [ppm] 1
  Response time 0.5 s
  Warm-up time ~ 45 s
Pump kit
  Standard pump capacity [L/min]
  Max. pump capacity (l/min) [l/min]
  Standard pump capacity (mbar) [mbar]
  Max. pump capacity (mbar) [mbar]
  Pump type
  Power supply
  Power input [kW]
  Approx. power input [mA]
  Standard battery capacity ( > 0 °C) [h]
  Battery capacity at maximum pump performance ( > 0°C) [h]
Material of sensor element
  Other
  Stainless steel
  Aluminium
  Composite
  Polycarbonate
Material of handle
  Material Plastics
  Plastic/metal
  Metal
Interfaces / plug design
  Plug design SDI connector
  Special 5-pin plug
Surrounding conditions (measuring electronics handle)
  Min. operating temperature [°C] -10
  Max. operating temperature [°C] 60
Functions and features
  Robust sinter filter for sensor protection
  Flexible gooseneck
  Integrated connection cable
Weight
  (packaging excluded) [kg] 0.5
Ascertainable measured values and functions
Internal sensors
  H2 hydrogen gas [digits]
Functions and features
  Robust sinter filter for sensor protection
  Flexible gooseneck
  Integrated connection cable
  Functional knob with connected active suction pump
  Shielded sensor tip for penetration of soft ground
  Rubber sleeve for better sealing
  Sinter protection cap
  Screw-on hollow extension rods

 standard equipment

 optionally available

 not available

LD6000 H2-Ground Sensor

LD6000 H2-Ground Sensor incl. Pump kit show in Trotec online shop
Technical data
General information
  Article number 3.110.008.020
H2gas [ppm]
  Min. measuring range | H2 gas [ppm] 10
  Max. measuring range | H2 gas [ppm] 20,000
  Resolution | H2 gas [ppm] 1
  Response sensitivity | H2 gas [ppm] 1
  Response time 0.5 s
  Warm-up time ~ 45 s
Pump kit
  Standard pump capacity [L/min] 1.5
  Max. pump capacity (l/min) [l/min]
  Standard pump capacity (mbar) [mbar]
  Max. pump capacity (mbar) [mbar]
  Pump type
  Power supply 9 V
  Power input - addition With unrestricted flow
  Approx. power input [mA] 45
  Standard battery capacity ( > 0 °C) [h]
  Battery capacity at maximum pump performance ( > 0°C) [h]
Material of sensor element
  Other
  Stainless steel
  Aluminium
  Composite
  Polycarbonate
Material of handle
  Material Plastics
  Plastic/metal
  Metal
Interfaces / plug design
  Plug design Special 5-pin plug
  SDI connector
Surrounding conditions (measuring electronics handle)
  Min. operating temperature [°C] -10
  Max. operating temperature [°C] 60
  Min. storage temperature [°C]
  Max. storage temperature [°C]
Functions and features
  Screw-on hollow extension rods
  Functional knob with connected active suction pump
  Rubber sleeve for better sealing
  Integrated connection cable
Dimensions
  Length (packaging excluded) [mm] 960
  Width (packaging excluded) [mm] 95
  Height (packaging excluded) [mm] 95
  Diameter (packaging excluded) [mm] 95
Weight
  (packaging excluded) [kg] 1.1
Ascertainable measured values and functions
Internal sensors
  H2 hydrogen gas [digits]
Functions and features
  Screw-on hollow extension rods
  Functional knob with connected active suction pump
  Rubber sleeve for better sealing
  Integrated connection cable
  Flexible gooseneck
  Shielded sensor tip for penetration of soft ground
  Robust sinter filter for sensor protection
  Sinter protection cap

 standard equipment

 optionally available

 not available