TAC XT – application area thermal disinfestation
The TAC XT as a mobile solution for thermal pest control and vermin elimination
Powerful thermal disinfector for professional pest control
Our world is characterised by increasing mobility which enables "stowaways" – undesirable parasites – to spread with the same speed. A constant coming and going in hotels, restaurants, hospitals, barracks, prisons or warehouses does not only enclose guests, inhabitants and goods, but unfortunately harmful insects, too.
Bedbugs, mites, meal beetles, cockroaches, clothes and food moths or other arthropods harmful for stock and furniture – as quickly as they're there, as harder it is to get rid of them.
The TAC XT serves as your pest exterminator 2.0
Instead of eliminating undesirable parasites with traditional pest control and toxic and environmentally hazardous substances, let the TAC XT get the job done for you. More effective than conventional procedures while 100 % environmentally friendly, without any chemicals or insecticides!
Thanks to the high heating capacity of the mobile TAC XT, time-consuming separation measures of the infested areas or complicated reconstruction and dismantling work will be unnecessary. Moreover, complex approval procedures or restrictions are no longer required when using the TAC XT. Set up, select programme automation and disinsectise efficiently – too easy with the TAC XT!
Effective technology for harming the harmful
Heat treatment is a highly efficient procedure for pest control since insects only have very limited options to regulate their body temperature as they cannot sweat. At temperatures from 45 °C onwards, the proteins in their bodies will start to coagulate and enzymes will be destroyed.
With a conventional heating device alone, these vermin can no longer be handled. The parasites would recognise a sudden increase in heat as danger and immediately escape.
Integrated automatic control system for thermal disinfestation
The multi air handler TAC XT can be controlled via touchscreen and is equipped with different automatic programmes, which can be adapted to your needs (e.g. to the respective room size). A smart automatic control system then initiates the thermal disinfestation process during which the room air temperature will slowly be increased step by step.
Afterwards, the disinfestation cycle will be launched: Both room air temperature and contact surfaces of the inventory will be heated to a temperature that can be preset up to ≤ 75 °C. Any kind of vermin within the treatment radius will then be killed. In a last step, the programme automatically starts the cooling phase.
If required, the treatment duration can be set from one hour to 80 hours. Besides, room and surface target temperatures can be individually configured.
Wide range of applications in the area of thermal pest control
18 kW heating capacity (27 kW optional), a ventilation performance of up to 2,500 m³ that can be adjusted in seven stages and an outlet temperature that can be set to 95 °C max. make the TAC XT a brilliant technological solution for many specific tasks.
The standard version with DualDecon blowing-out tower allows you to benefit from a multi air handler for thermal pest control that is suitable for the most diverse locations and applications:
- Hotels and holiday resorts
- Youth hostels and residential accommodations
- Army barracks and correctional facilities
- Commercial kitchens and bakeries
- Museum depots and archives
- Warehouses and silos
- Ships
- Suitable for organic farms
Designed to function as a flexible combined solution, the TAC XT can also be used for thermal decontamination, for HEPA room air purification or for mobile room heating, providing all-round warmth. This broad range of applications is the perfect base for short payback times.
All-round hygiene management for hotels, hostels or shared accommodations
Whether we’re talking about disinfestation, odour elimination or room air purification, with our modular concept of professional air treatment units such as the multi air handler TAC XT and the browser-based Trotec cloud application you’ll benefit from a comprehensive Hygiene solution for your company, individually customisable to any requirement and at the same time 100 % efficient, 100 % biological, 100 % chemical-free!
Via the cloud application with its integrated dashboard and analysis options, which is designed for a variety of uses, any materials to be treated – for instance mattresses, pillows, curtains or carpets – but also individual rooms and even different sites can be recorded. The combination with the mobile app in this way provides you with a comprehensive hygiene management solution which you can use to check and document the status of your hygiene concept easily and at all times from anywhere. Learn more …
Application area thermal disinfestation – practical benefits:
- 360° pest control with efficient programme automation: Incrementally increasing heating-up phase, effective disinfestation cycle with air temperatures of up to ≤ 70 °C and automatic cooling phase
- 100 % environmentally friendly, no chemicals, no insecticides
- Suitable for organic farms
- Highly effective against all types of pest species in their development stages (egg, larva, pupa, imago)
- 100 % odourless and free from allergenic substances
- No complex approval procedures or restrictions
- No reconstruction and dismantling works required
- Room/surface target temperature, adjustable up to 75 °C
- Rooms can be used immediately after disinfestation
Buy
MULTI-AIRHANDLER TAC XT 27
6,099.95 £ incl. VAT Show net price (VAT not included)
MULTI-AIRHANDLER TAC XT 18
5,599.95 £ incl. VAT Show net price (VAT not included)
MULTI-AIRHANDLER TAC XT 27
6,099.95 £ incl. VAT Show net price (VAT not included)
Technical data TAC XT 18
Technical data | ||
---|---|---|
General information | ||
Article number | 1.410.000.183 | |
Dust class | ||
as per DIN EN 1822 (ISO 45H filter ISO 29463) | H14 | |
as per DIN EN 779:2002 | F7 | |
Air flow rate | ||
Max. air volume flow [m³/h] | 2,100 | |
Recommended amount of air for HighFlow filter with filter class H14 ≤ [m³/h] | 1,200 | |
Recommended amount of air for HighFlow filter with filter class H13 ≤ [m³/h] | 2,100 | |
Heating capacity | ||
Level Max. [kW] | 18 | |
Temperature data | ||
Max. air outlet temperature [°C] | 95 | |
Room / surface target temperature [°C] | 75 | |
Electrical values | ||
Mains connection | 2 x 380 - 480 V/50 - 60 Hz | |
Power input [kW] | 18 | |
Nominal current consumption [A] | 15.9 | |
Recommended fusing [A] | 32 | |
Electric connection | ||
Connection plug | 2 x CEE 16 A | |
Sound values | ||
Sound level in compliance with ISO 11203 | 35 – 59 dB | |
Fan | ||
Radial | ||
axial | ||
stages | 2 | |
Dimensions | ||
Length (with wheels and handle) [mm] | 690 | |
Width (with wheels and handle) [mm] | 630 | |
Height (with wheels and handle) [mm] | 1,300 | |
Length Depending on the configuration (FlowExtender) [mm] | 690 | |
Width Depending on the configuration (FlowExtender) [mm] | 630 | |
Height Depending on the configuration (FlowExtender) [mm] | 2,300 | |
Weight | ||
(without packaging) - without HEPA filter [kg] | 93.1 |
Equipment, features and functions | ||
---|---|---|
Equipment | ||
Thermal filter decontamination | ||
Thermal filter regeneration | ||
FlowMatic control | ||
Operating hours counter | ||
Temperature adjustment/target value setting | ||
Temperature measurement of other rooms when connected to a ventilation system | ||
Automatic switch-off upon reaching the set value | ||
Self-regeneration function HEPA filter | ||
Filter change indication | ||
Timer function | ||
Frost monitor function | ||
Fan rundown function | ||
Setting the room dimensions | ||
Touchscreen | ||
Screensaver | ||
Steplessly adjustable thermostat | ||
Overheating protection | ||
Protective bar | ||
Filter change indication | ||
Pre-filter | ||
Main filter | ||
Mobility | ||
Carriage design | ||
Carry/transport handle(s) | ||
Wheels | ||
Feet | ||
Cable winder |
standard equipment
optionally available
not available