Advice for private customers: +49 2452 962-450

Advice for business customers: +49 2452 962-400

Mon - Fri: 9:00 - 17:00 (CET)

Air cleaner TAC 750 E
  1. Products & Services
  2. Products ‑ HighPerformance
  3. Air purification
  4. Air cleaner TAC 750 E

Air cleaner TAC 750 E

Extremely mobile and variably applicable lightweight – agreeably small in terms of costs and dimensions

Air cleaner TAC 750 E
Air cleaner TAC 750 E
Air cleaner TAC 750 E
Air cleaner TAC 750 E

Air purification made easy!

Whether for rebuilds, renovations or restorations – wherever there is construction work in progress the air is quickly contaminated with dust pollutants, endangering the health of employees or residents and polluting adjacent areas.

Here, the lightweight TAC 750 E constitutes the perfect solution for air cleaning in smaller construction zones and air pollution control in the surrounding facilities – due to its compact dimensions it also conveniently fits into even the smallest trunk.

Developed specifically as vacuum generator for dust‑laden rooms, the TAC 750 E with its effective two‑stage filter system ensures reliable HEPA filtration of the contaminated room air to protect against health hazards and dirt!

Using the TAC 750 E air purification becomes mere child's play

As the lightest air cleaner of its class, the TAC 750 E can be transported from one construction site to another without difficulty and be put into operation just as easily.

The infinitely adjustable air volume regulation enables an energy-efficient adjustment of the fan performance to the required air exchange rates for the respective construction zone.

With the range of available filters you can flexibly use the TAC 750 E as two-stage filter system for air cleaning in construction zones or for the extraction of spray paint mists in case of airless or compressed-air applications.

In addition to the standard connection for 203-mm hoses, smaller 127-mm hoses for air extraction can also be connected to the TAC 750 E using an optional hose adapter.

This way, the ideal hose connection is available for any requirement ranging from pinpoint suction to maintaining the pressure.

Air cleaner TAC 750 E

Since the TAC 750 E was scrupulously optimized for effective suction operation, it can optionally be applied either for air circulation directly in sealed-off areas or outside for maintaining the pressure via a hose connection:

Air purification in sealed off area via air circulation.
Air purification in sealed off area
Maintaining the pressure outside of the room via air hose.
Maintaining the pressure outside of the room

A few practical benefits:

  • Professional quality "Made in Germany" – originally produced by Trotec
  • Versatile filter system for dust collection or the extraction of spray paint mists
  • Extremely light – weighs only 6 kg (empty)
  • Powerful premium fan
  • Infinite adjustment of air volume
  • Impact-proof and robust ABS housing, recyclable to 100 %
  • Low-maintenance construction with quick release fasteners for simple filter change
  • Compact dimensions – easily fits into every trunk
  • Can be connected to different hose diameters
  • Handy cable organiser for safe transport

Recommendation for filter combinations specific to the application and corresponding room size suitability

TAC air cleaner TAC 750 E TAC 1500 S TAC 1500 TAC 3000 TAC 5000 TAC 6500
Field of application Filter combination Suitable for rooms to a size of ¹
Coarse dust ²
(≤ 3 LW/h ⁶)
G4 250 100 220 88 220 88 500 200 1,200 480 1,400 560
Fine particulates ³
(≤ 3 LW/h ⁶)
G4 + F7 to F9 110 44 110 44 270 108 600 240 750 300
Suspended matter ⁴
(≥ 10 LW/h ⁶)
G4 + H13/H14 25 10 50 20 50 20 100 40 150 60 200 80
Hygienic areas ⁵
(≥ 15 LW/h ⁶)
G4 + H13/H14 12.5 5 35 14 35 14 70 28 110 44 135 54
¹ With an assumed room height of 2.5 m; ² Typical coarse dust tasks: sawing, filing; ³ Typical fine dust tasks: restoration works with materials containing minerals or glass wool; ⁴ Typical suspended matter tasks: grinding, asbestos abatement or mould remediation, mineral dusts etc.; ⁵ H13/H14 downstream; ⁶ Air exchange per hour

Virus filtering also possible now!

H14-hepa filter for corona application available now

For the H13 HEPA filter compartment of all professional air cleaners of the TAC series, as of now also high-performance filters of the class H14 are available as consumables for virus filtering.

These final filters for cleanrooms of classes ISO 4 and ISO 3 feature a separation efficiency of 99.995% at a particle size of 0.1 to 0.2 µm.  

Viral strains such as SARS-CoV, MERS-CoV or SARS-CoV-2 (Covid-19) show similar particle sizes, recent studies for example specify the particle size of the coronavirus to 120 to 160 nanometres, i.e. 0.12 to 0.16 µm.

Such particle sizes can be effectively separated by means of the H14 filters, especially since viruses in the air generally occur in combination with saliva or suspended matters as larger conglomerates.


All H14 filters meet highest quality standards that are mandatory in particular for sensitive applications in bacteria and virus filtering:

  • Each filter is tested and receives an individual serial number
  • The test report is enclosed as certificate in duplicate with every filter package
  • The customers can store the original copy of the certificate and attach the copy to the device, if required.
  • Tests are carried out in compliance with EN 1822 and DIN EN 60335-2-69

Trotec: Innovation made in Germany

Take a look behind the scenes: As one of the internationally leading manufacturers of air treatment solutions, Trotec offers industrial and commercial customers innovative products for air purification, dehumidification, heating, air conditioning and ventilation. We rely 100 % on research, development, design and production in Germany for our high-performance devices. For the highest quality requirements, sophisticated system solutions and fresh ideas.

Watch the video to see for yourself!

Shop

TAC 750 E Air Purifier show in Trotec online shop

Technical data

Technical data
General information
  Article number 1.580.000.101
Dust class
  as per DIN EN 60335-2-69 H
Air flow rate
  Max. air volume flow [m³/h] 750
  Negative static pressure [Pa] 720
  Recommended amount of air for filter class H [m³/h] 290
  Air volume with filter surface H13 > [m²] 2.15
  Air volume with G4 filter [m³/h] 680
Vario-shift function
  For variable filter configuration
Electrical values
  Mains connection 230 V, 50/60 Hz
  Power input [kW] 0.12
  Nominal current consumption [A] 1
  Recommended fusing [A] 6
Electric connection
  Connection plug CEE 7/7, H05RN-F
  Cable length [m] 3
Air transport hose connector
  Suction side ø [mm] 200
  Blow-out side ø [mm]
Sound values
  Distance 1 m [dB(A)] 77
Fan
  Radial
  stages Infinitely variable
Dimensions
  Length (packaging excluded) [mm] 315
  Width (packaging excluded) [mm] 430
  Height (packaging excluded) [mm] 430
Weight
  (packaging excluded) [kg] 6
Equipment, features and functions
Equipment
  Infinite adjustment of air volume
  FlowMatic regulation of air volume
  Thermal filter decontamination
Filter change indication
  Pre-filter
  Main filter
Filter
  combination Coarse dust (≤ 3 ACH) G4
  Suitable for rooms sized up to Coarse dust (≤ 3 ACH) [m³] 250
  combination Fine particulates (≤ 3 ACH) G4
  Suitable for rooms sized up to Fine particulates (≤ 3 ACH) [m³] 250
  combination Suspended matter (≥ 10 ACH) G4 + H13
  Suitable for rooms sized up to Suspended matter (≥ 10 ACH) [m³] 25
  combination Hygienic areas (≥ 15 ACH) G4 + H13
  Suitable for rooms sized up to Hygienic areas (≥ 15 ACH) [m³] 16
Mobility
  Carry/transport handle(s)
  Non-marking rubber feet
  stackable
  Swivel casters with parking brakes
  Trestle rollers/ fixed castors
  Full-rubber guide wheels
  Guiding wheels pneumatic tyres
  Stacking frame
  Forklift pockets
  Shock protection frame
  Non-marking rubber wheels/rollers

 standard equipment

 optionally available

 not available

Accessories

Loading...

Downloads

Loading...