CM material moisture measuring devices
For a quick and reliable moisture determination in building materials
CM measurements provide protection against expensive complaints later on.
Professionals already know: Structural damages are often attributable to excessive residual moisture in the ground.
With Trotec's CM Complete sets you can carry out your measurements quickly and reliably. This way, the residual moisture content in processed construction materials such as floor beddings etc. can be precisely determined directly on site and without the need for additional aids or tools and documented with the supplied log printer (CM Set Business).
Multiple print-outs simplify the administration and in case of a dispute provide proof that the mandatory testing requirements have been met.
Thanks to the accurate measuring technology, you can do without time-consuming laboratory tests.
The value displayed on the pressure gauge corresponds to the actual residual moisture in per cent – no laborious conversion required.
Surface thermometer to avoid measurement errors ...
The conversion tables of all CM devices that are usually available on the market are based on a constant ambient temperature of 20 °C. In the best case, this temperature is present at the beginning and also at the end of a measurement.
If this reference temperature is deviated at the beginning or end of a measurement and not observed, this will result in a more or less relevant error depending on the degree of deviation:
For every 3 °C deviation, the error is 1 % of the pressure (the temperature is the same at the beginning and end of the measurement).
For this reason, all Trotec CM devices are equipped with a surface thermometer which indicates the cylinder temperature. This way, any temperature errors can be detected.
If, for example, a measurement was performed at a constant temperature of 35 °C and a pressure of 0.8 bar was indicated, the CM % moisture content for a sample of 50 g according to the table or scale is 1.57 CM %.
The same measurement carried out at a constant temperature of 20 °C would have resulted in a pressure of 0.76 bar (5 % less) and thus in a moisture value of 1.49 CM %.
The Trotec CM complete sets convince with their easy operability and high precision:
CM Complete Set Classic
The classic among the CM measuring devices
In the CM Classic you have a reliable, professional CM measuring device that comes equipped with a mechanical pressure gauge with pressure overload protection to 2.5 bar.
Trotec provides the CM Classic in a Complete Set comprising measuring device and CM basic case.
CM Complete Set Business
The professional CM measuring device with digital precision
In the CM Business you have a professional precision measuring device that comes equipped with a digital pressure gauge with pressure overload protection to 3 bar.
Trotec provides the CM Business in a Complete Set comprising measuring device and CM basic case.
Pressure gauge model | Classic | Business | |
---|---|---|---|
Equipment differences |
Pressure measurement principle | depending on ambient conditions | regardless of ambient conditions |
Interdependence of indicated pressure | correlated | none | |
Splash water protection / dust protection | Standard | excellent (steel membrane) | |
Online check | no | yes | |
Measuring time display | no | yes | |
Logging option on site | no | yes | |
Storage of measured values | no | yes | |
Individual log printing | no | yes | |
Maintenance effort | check regularly | Very low | |
techn. characteristics |
Accuracy class pressure gauge | 1.0 | 0.1 |
Measuring range | max. 2.5 bar | -1 to 2 bar | |
Pressure overload protection | decent | decent | |
Max. fault tolerance (mbar) | ± 25 | ± 2 | |
Attenuation pressure gauge cover | DIN-EN 837-2 | DIN-EN 837-2 | |
Serial interface | – | RS485 | |
Direct reading of CM % moisture |
10 g | – | ✓ |
20 g | ✓ | ✓ | |
50 g | ✓ | ✓ | |
100 g | ✓ | ✓ | |
Other | bar | yes | |
Power supply | – | Durable battery (approx. 3,000 h) |
Contents of the CM basic case:
- Digital scales
- Weighing capacity 150 g
- Minimum partition 0.1 g
- Display stabilization within 3 seconds
- Mechanical protection by means of weighing plate cover
- Overload and low voltage indication
- Automatic switch-off function
- Calibration weight (100 g) and batteries included in the scope of delivery (3 x 1.5 V of type AAA)
- Weighing beakers (2 pc.)
Weighed portion can be filled directly into the cylinder – no more spilling, how convenient - Full tool kit for sample preparation
- Ball set with 4 steel balls (starting, blending and grinding effect)
- 20 pieces of carbide ampoules
- Three test ampoules with 1.00 g water for cylinder leak test/pressure gauge test
- Three spare seals each for pressure gauge and pressure cylinder, spoon and cleaning brush
- Lucid operating instructions and quick start guide
- Metal carrying case – everything stays in its place, protected for transport
CM log printer
For the documentation of your CM measured data directly on site
Comes fully equipped with protective cover, charger and spare roll of paper. Prints the measuring result directly as log. It is possible to create several print-outs with log numbers during one measurement only.
The log comprises:
- Adjustable log heading for company data and information on the measuring point
- Selection list for the measured test material
- Pressure curve during measurement
- Overall measurement duration in minutes and seconds
- Automatic calculation of the CM % moisture for 10, 20, 50 and 100 g weighed portions
- Adjustable log footer for documentation, location, user and building owner
The CM log printer is the ideal supplementation for the CM set Business...
Hint: combined moisture measurement
Increased safety based on combined check of the readiness for covering
CM measuring is a generally accepted test method for the evaluation of the readiness for covering of screeds. As with all methods of measurement, however, the use of only one procedure can always lead to misinterpretation.
Recently craftsmen and building owners have had to deal in court with the problem that in individual cases CM measurement results indicated the readiness for covering, even though the screed just wasn't ready!
Therefore, play it safe and combine the floor moisture content measurement method approved in continental Europe (CM measurement) with the equilibrium moisture content measurement which has become established as standard method for many a year in e.g. Northern Europe.
In case of the combined moisture measurement, first the equilibrium moisture content and then the moisture content of the sample is determined by use of the very same sample.
The combined moisture measurement method affords users of CM measuring devices more security when assessing the readiness for covering of screeds without causing significant additional expenses. Moreover, the familiar CM measuring device can be used for this additional measurement.
The determination of both values – equilibrium moisture content and moisture content of the sample – allows for a more reliable assessment of the readiness for covering than just one of the two measurement methods.
Since both measuring results have been determined using the same sample, combined moisture measurement results in yet more security for the floor layer!
Required equipment for combined moisture measurement: Other than the already available CM device, only the CM hygro combination cap and a T210 thermohygrometer are required, or, if a T3000 measuring device is available, a TS 210 SDI climate sensor is needed.
A few practical benefits:
- Robust design in metal carrying case
- For weighed portions of 100 g (calcium sulphate flow screed)
- Attractive value-for-money ratio
- Direct indication of CM moisture with an accuracy class to 0.1 % (Business)
- Log printer documentation protects against damages and follow-up costs (Business)
- Complete sets with 2 precision pressure gauges – optionally either mechanical or digital
Buy
CM Set Classic
549.95 £ incl. VAT Show net price (VAT not included)
CM Suitcase Business without printer
799.95 £ incl. VAT Show net price (VAT not included)
CM Protocol Printer
449.95 £ incl. VAT Show net price (VAT not included)
Techn. data CM set Classic
Technical data | ||
---|---|---|
General information | ||
Article number | ZB9100100 | |
Pressure [bar] | ||
Accuracy class pressure gauge | ± 1.0 % typ. ± 25 mbar (absolute, over the entire pressure range) | |
Overload-proof to | 3.0 | |
Interfaces | ||
RS232-TTL or RS232-V.24 | ||
RS485 serial | ||
Display | ||
LCD | ||
Touch | ||
Type of protection | ||
IP32 | ||
IP64 | ||
Device control | ||
Membrane keyboard | ||
Housing design | ||
Plastics | ||
Maintenance effort | ||
Regular checks required | ||
Very low | ||
Power supply | ||
Internal via battery | ||
External via car power adapter | ||
Internally via battery | ||
Ambient conditions | ||
Min. operating temperature [°C] | -10 | |
Max. operating temperature [°C] | 80 | |
Dimensions | ||
Length (packaging excluded) [mm] | 140 | |
Width (packaging excluded) [mm] | 520 | |
Height (packaging excluded) [mm] | 360 | |
Weight | ||
(packaging excluded) [kg] | 8.3 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Digital scales | ||
Weighing beakers | ||
Full tool kit for sample preparation | ||
Ball set with 4 steel balls | ||
20 carbide ampoules | ||
3 test ampoules | ||
3 spare seals pressure gauge | ||
3 spare seals pressure cylinder | ||
Carrying case | ||
Operating manual | ||
Battery(-ies) | ||
Battery pack 4.8 V / 1.650 (typ.) mAh NiMH | ||
Charger 220 V | ||
Printer connection cable (special type RS232-TTL) | ||
Paper reel for thermal printing |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Material moisture [CM-%] | ||
Pressure [bar] | ||
Wood moisture [%] | ||
Material moisture [%] | ||
Material moisture [digits] | ||
Functions and features | ||
Dust cover | ||
Direct reading CM-% for 100 g | ||
Direct reading CM-% for 20 g | ||
Direct reading CM-% for 50 g | ||
Splash guard | ||
Interdependence of indicated pressure and ambient pressure | ||
Automatic switch-off | ||
Acoustic alarm function | ||
Selection sensor characteristic map (sens) | ||
Automatic battery test | ||
Automatic functional test | ||
Direct reading CM-% for 10 g | ||
Display illumination | ||
Retaining clip | ||
Selection of wood material characteristics (Mat) | ||
Individual log printing | ||
Maximum value display | ||
Measuring time display | ||
Measured value hold function | ||
Storing measured values on the PC via live data export | ||
Minimum value display | ||
Mode selection slide control | ||
Online check | ||
Logging option on site | ||
Manual temperature setting | ||
Temperature compensation | ||
Unit 2 | ||
Non-destructive measurement method |
standard equipment
optionally available
not available
Techn. data CM set Business
Technical data | ||
---|---|---|
General information | ||
Article number | ZB9100106 | |
Pressure [bar] | ||
Max. fault tolerance [mbar] | ± 2 | |
Accuracy class pressure gauge | ± 0.1 % typ. ± 4 mbar (absolute, over the entire pressure range) | |
Attenuation pressure gauge cover | DIN-EN 837-2 | |
Overload-proof to | 3.5 | |
Interfaces | ||
RS485 serial | ||
RS232-TTL or RS232-V.24 | ||
Display | ||
LCD | ||
Touch | ||
Type of protection | ||
IP64 | ||
IP32 | ||
Device control | ||
Membrane keyboard | ||
Housing design | ||
Plastics | ||
Maintenance effort | ||
Very low | ||
Regular checks required | ||
Power supply | ||
Internal via battery | ||
External via car power adapter | ||
Ambient conditions | ||
Min. operating temperature [°C] | 0 | |
Max. operating temperature [°C] | 50 | |
Dimensions | ||
Length (packaging excluded) [mm] | 140 | |
Width (packaging excluded) [mm] | 520 | |
Height (packaging excluded) [mm] | 360 | |
Weight | ||
(packaging excluded) [kg] | 8.3 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Digital scales | ||
Battery(-ies) | ||
Weighing beakers | ||
Full tool kit for sample preparation | ||
Ball set with 4 steel balls | ||
20 carbide ampoules | ||
3 test ampoules | ||
3 spare seals pressure gauge | ||
3 spare seals pressure cylinder | ||
Operating manual | ||
Carrying case | ||
Battery pack 4.8 V / 1.650 (typ.) mAh NiMH | ||
Charger 220 V | ||
Printer connection cable (special type RS232-TTL) | ||
Paper reel for thermal printing |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Material moisture [CM-%] | ||
Pressure [bar] | ||
Wood moisture [%] | ||
Material moisture [%] | ||
Material moisture [digits] | ||
Functions and features | ||
Dust cover | ||
Individual log printing | ||
Measuring time display | ||
Storing measured values on the PC via live data export | ||
Online check | ||
Logging option on site | ||
Splash guard | ||
Interdependence of indicated pressure and ambient pressure | ||
Automatic switch-off | ||
Acoustic alarm function | ||
Selection sensor characteristic map (sens) | ||
Automatic battery test | ||
Automatic functional test | ||
Direct reading CM-% for 10 g | ||
Direct reading CM-% for 100 g | ||
Direct reading CM-% for 20 g | ||
Direct reading CM-% for 50 g | ||
Display illumination | ||
Retaining clip | ||
Selection of wood material characteristics (Mat) | ||
Maximum value display | ||
Measured value hold function | ||
Minimum value display | ||
Mode selection slide control | ||
Manual temperature setting | ||
Temperature compensation | ||
Unit 2 | ||
Non-destructive measurement method |
standard equipment
optionally available
not available
Techn. data CM printer
Technical data | ||
---|---|---|
General information | ||
Article number | ZB9100043 | |
Interfaces | ||
RS232-TTL or RS232-V.24 | ||
RS485 serial | ||
Display | ||
LCD | ||
Touch | ||
Type of protection | ||
IP32 | ||
IP64 | ||
Device control | ||
Membrane keyboard | ||
Housing design | ||
Plastics | ||
Metal | ||
Maintenance effort | ||
Regular checks required | ||
Very low | ||
Power supply | ||
Internal via battery | ||
External via car power adapter | ||
Internal (battery) | ||
Dimensions | ||
Length (packaging excluded) [mm] | 140 | |
Width (packaging excluded) [mm] | 520 | |
Height (packaging excluded) [mm] | 360 | |
Weight | ||
(packaging excluded) [kg] | 0.205 |
Standard scope of delivery | ||
---|---|---|
Standard scope of delivery | ||
Device | ||
Battery pack 4.8 V / 1.650 (typ.) mAh NiMH | ||
Charger 220 V | ||
Paper reel for thermal printing | ||
Printer connection cable (special type RS232-TTL) | ||
Operating manual | ||
Battery(-ies) | ||
Digital scales | ||
Weighing beakers | ||
Full tool kit for sample preparation | ||
Ball set with 4 steel balls | ||
20 carbide ampoules | ||
3 test ampoules | ||
3 spare seals pressure gauge | ||
3 spare seals pressure cylinder | ||
Carrying case |
Ascertainable measured values and functions | ||
---|---|---|
Internal sensors | ||
Pressure [bar] | ||
Wood moisture [%] | ||
Material moisture [%] | ||
Material moisture [CM-%] | ||
Material moisture [digits] | ||
Functions and features | ||
Interdependence of indicated pressure and ambient pressure | ||
Automatic switch-off | ||
Acoustic alarm function | ||
Selection sensor characteristic map (sens) | ||
Automatic battery test | ||
Automatic functional test | ||
Direct reading CM-% for 10 g | ||
Direct reading CM-% for 100 g | ||
Direct reading CM-% for 20 g | ||
Direct reading CM-% for 50 g | ||
Display illumination | ||
Retaining clip | ||
Selection of wood material characteristics (Mat) | ||
Individual log printing | ||
Maximum value display | ||
Measuring time display | ||
Measured value hold function | ||
Storing measured values on the PC via live data export | ||
Minimum value display | ||
Mode selection slide control | ||
Online check | ||
Logging option on site | ||
Splash guard | ||
Dust cover | ||
Manual temperature setting | ||
Temperature compensation | ||
Unit 2 | ||
Non-destructive measurement method |
standard equipment
optionally available
not available