Gas heater fan TGH 16 E
Gas heater fan with a heating capacity of 15 kW for effectively heating even larger, well-ventilated spaces
Affordable instant heat
When it comes to affordable instant heat for construction sites, workshops, stables or greenhouses, there is practically no other way than using a gas heating device. For gas is a low-priced energy source – and combined with the inexpensive heater fan TGH 16 E it makes for one of the most economic and simultaneously effective instant heating solutions.
The robust branded gas heater fan TGH 16 E not only impresses with its outstanding value-for-money ratio, it goes without saying that safety is also a major priority with this propane heater.
Instant heat – exactly where it is required
An integrated temperature sensor serves as flame failure protection and prevents the emission of unburnt gas. Moreover, the standard equipment includes a safety thermostat for overheating protection which automatically interrupts the gas supply in case of overheating while the fan continues to run to ensure the necessary cooling. The specially shaped discharge grille of the gas heater fan TGH 16 E prevents direct contact with the flame whilst ensuring an optimally swirled, high-volume current of warm air.
Last but not least, the thermally insulated transport handle permits the safe and simple transportation to the next operating site where the gas heater fan TGH 16 E – thanks to additionally fitted slip-proof rubber feet – can be set up safely. Owing to its extremely compact design, the heating device can easily be transported even in the smallest of car boots.
Compact and versatile heating solution
For instance, you can use the gas heater fan TGH 16 E for mobile spot heating of well-ventilated construction sites, workshops, storage spaces, garages, stables, greenhouses or else roofed outdoor areas, tents and marquees. Rough operating conditions hardly matter to this heating device, as it comes with a hard-wearing, robust metal construction including space heater in powder-coated corrugated sheet metal design.
Since connection hose and pressure reducer for connecting the gas cylinder are already included in the scope of delivery of this heating device, nothing more than a socket and a propane cylinder is required for the heating operation. The long connection cable increases your flexibility in selecting the installation site.
Once in operation, agreeable warmth begins to spread immediately, seeing as the integrated turbo blower of the TGH 16 E ensures an effective air flow made up of sucked in ambient air and blown out warm air. Even larger rooms can quickly be heated in this manner.
Important information about direct gas heaters
Gas heaters are recommended for use in well-ventilated indoor and covered outdoor areas, where all the heat developed is actually available (100 % output).
Important:
In addition to heat, gas fan heaters also emit combustion exhaust gases directly into the room. They are therefore unsuitable for closed rooms without good ventilation if people or animals are present in them.
In addition, approx. 1.6 kg of water vapour is produced per litre of fuel during combustion. Direct gas heaters are therefore not suitable for drying buildings. If gas heaters were used to dry out buildings, the worst that could happen would be that the building would be damper than before!
Gas heaters must also not be used in rooms at risk of fire, e.g. due to the storage of flammable materials.
Good to know: Gas heater fans …
- are suited for the use in well-ventilated interior spaces and roofed outdoor areas
- generate a heating capacity of 100%
- emit combustion waste gases directly into the room along with the heated air
- are not suitable for the use in closed rooms
- cannot be used for construction drying, since the combustion generates approx. 1.6 kg of water vapour per litre of fuel
- must not be used in rooms with a fire hazard due to the storage of flammable substances
A few practical benefits:
All gas heater fans in direct comparison:
To find the gas heater fan which exactly meets your requirements, please consult the concise overview of all gas heaters of the TGH-E series from Trotec, which we're providing to you here so that you can compare them directly to each other.
Models which you do not wish to include in your comparison can be easily dismissed with only one click.
Practical knowledge guidebook – heating know-how for professional users
Benefit from first-hand manufacturer know-how: On our guidebook pages we’re providing you with some detailed information regarding the different types of heaters including a functional description, focuses of application and lots more.
Continue to the practical knowledge guidebook for professional heating
Buy
Gas heater fan TGH 16 E
You save: 25.00 £
119.95 £
94.95 £
incl. VAT
Show net price (VAT not included)
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 1.420.000.021 | |
Functional principle | ||
Gas | ||
Operating pressure [bar] | 0.7 | |
Air flow rate | ||
Air volume [m³/h] | 580 | |
Air outlet temperature | ||
(1.5m distance) [°C] | 79.5 | |
Room size | ||
Min. room size [m³] | 150 | |
Ventilation cross-section | ||
Min. ventilation cross-section [cm³] | 375 | |
Fan | ||
axial | ||
stages | 1 | |
Heating capacity | ||
Level 1 [kW] | 15 | |
Operating range | ||
Min. temperature [°C] | -15 | |
Max. temperature [°C] | 30 | |
Electrical values | ||
Mains connection | 220 - 240 V, 50 Hz | |
Max. power input [kW] | 0.05 | |
Nominal current consumption [A] | 0.33 | |
Electric connection | ||
Connection plug | CEE 7/4 | |
Cable length [m] | 1.3 | |
Sound values | ||
Distance 1 m [dB(A)] | 48 | |
Safety feature | ||
Overheating protection [°C] | 95 | |
Protection class | I | |
Housing design | ||
Sheet steel – coated | ||
Dimensions | ||
Length (packaging excluded) [mm] | 380 | |
Width (packaging excluded) [mm] | 190 | |
Height (packaging excluded) [mm] | 305 | |
Weight | ||
(packaging excluded) [kg] | 4 |
Equipment, features and functions | ||
---|---|---|
Functions and features | ||
Operating control lamp | ||
Flame failure protection | ||
Start-up button | Piezo ignition |
standard equipment
optionally available
not available