![Proven Trotec quality: The PT 6500 HT commercial air conditioner for high ambient temperatures up to +55 °C Proven Trotec quality: The PT 6500 HT commercial air conditioner for high ambient temperatures up to +55 °C](images/proven-trotec-quality-the-pt-6500-ht-commercial-air-conditioner-for-high-ambient-temperatures-up-to-55-c-4c72.jpg)
High-temperature commercial air conditioner PT 6500 HT
This mobile split air conditioner performs at its best even at high outside temperatures – can be used up to +55 °C ambient temperature
PT 6500 HT – the name says it all:
HT stands for “High Temperature”, as these are exactly the climatic conditions for which the mobile air conditioner PT 6500 HT has been designed.
It is not only in T3 climate zones that extreme outdoor temperatures prevail in the summertime. Even in previously more temperate climate zones, heat waves with very high temperatures are becoming more frequent. Conventional air-conditioners quickly reach their limits because their construction usually only allows them to operate as intended up to a maximum ambient temperature of +38 °C.
PT 6500 HT air conditioner – the mobile solution for high-temperature environments
Whereas the outside of the housing is structurally identical to its sister model PT 6500 S, all internal components of the PT 6500 HT's compressor refrigeration system are designed for use even in extreme summer conditions with temperatures up to +55 °C. In combination with the more powerful PT S+ heat exchanger, all components reliably generate a continuous flow of cooling air in environments with a temperature range of +7 to +55 °C.
The special cooling unit design of the PT 6500 HT ensures that this mobile air conditioner can provide maximum cooling performance even in extreme temperature conditions in T3 climate zones. And Duplex-Cooling even makes it possible to extend the application area to environments up to +60 °C.
Powerful cooling technology for continuous operation in high-temperature environments
Numerous detailed solutions prove the soundness and high quality of this professional air conditioner. For example we used super robust finned aluminium heat exchangers with thick-walled copper tubing. Additionally, the heat exchangers' rotary compressor was fitted on vibration absorbers to ensure the maximum lifetime. In addition, all internal components of the compression refrigeration system are designed for the use in high ambient temperatures up to +55 °C. Thus, a powerful centrifugal fan with radial flow ensures large-volume cold air circulation.
Once installed at the site of operation, the PT 6500 HT is ready for use within only a few minutes. For the power connection you simply require a 230 V outlet, and thanks to the connection set with quick-lock couplings, the connection to the external heat exchanger is established in no time. The connection line just contains circulating water mixed with glycol, so that there is no refrigerant loss when the PT 6500 HT is connected and disconnected. And by combining several connection sets the covered distance may be increased to maximally 30 metres, if required. This permits the cooling of remote, windowless rooms.
Typical applications:
- Personnel cooling in high-temperature environments such as steelworks, aluminium foundries, copper works
- Cooling of guest or staff areas in tropical climates
- Mobile cooling even under T3 climate zone conditions
- Reliable permanent cooling of computer rooms, measuring and control centres
Connecting as quick as lightning thanks to water cooling circuit with quick release fastener
Installing connecting lines flexibly, quickly and easily – this feature is certainly a plus:
The air conditioning systems of the PT series come with two separate cooling circuits. The refrigerant circuit of the basic device is hermetically sealed. By contrast, another circuit is installed between cooling unit and external heat exchanger for cooling the condenser as well as for heat removal using a connection set. In this additional circuit only water with a low glycol concentration circulates as cooling medium, thus ruling out a loss of refrigerant when connecting or disconnecting the devices in a professional fashion.
For a quick installation of the water and power lines between air conditioner and heat exchanger the connection sets of these air conditioning systems come equipped with high-class quick-lock couplings. As a result, even longer connections over a distance of up to 30 metres can be realized without difficulty in a quick, clean and easy manner – ideal for office, server or production rooms, control centres or studios, where there is hardly ever any room to accommodate such heat dissipation measures.
Plano PT even opens up installation paths to you the access to which has been denied to you so far
The exclusive Trotec PlanoPT Allows for the installation of the PT connecting lines underneath all common interior and exterior doors. In this way, even rooms without a conventional installation access can be equipped with cooling units by means of the patented PlanoPT. Find out more about the benefits of Trotec's PlanoPT ...
Optional passage underneath doors with PlanoPT
Split design – bundled cooling power
The interior unit of the PT 6500 HT houses a powerful cooling compressor system with a hermetic refrigerant circuit. Within this circuit, the sucked-in room air is cooled down to the setpoint temperature selected and then emitted as cooling air to the room again via the pressure-resistant radial fan. The air recirculation of the PT 6500 HT provides the additional benefit that neither interior air is consumed nor underpressure is generated.
As a result of the process, refrigeration also produces heat. In order to prevent this heat from also entering in the room air again, the process heat generated in the condenser is dissipated in a separate system via a circulating cooling medium to the external heat exchanger by means of a pump.
The connection between the interior unit and the externally placed heat exchanger can be quickly established using the PT connection sets. They are provided with quick-lock couplings and allow for an overall installation path of up to 30 metres between the interior and external unit.
The cooling medium circulating in the connecting lines is only water with a low glycol fraction, thus preventing the loss of refrigerant when the devices are professionally mounted and dismounted.
In the external unit the cooling medium then flows through a large-volume heat exchanger, through which sucked-in ambient air is blown for the purpose of thermal absorption. In a last step, the cooling medium with its now reduced temperature flows back to the interior unit via the connecting line to absorb new heat there.
Invaluable practical benefits for rental companies
A high degree of versatility by Duplex cooling with DualHex coupling – ideal for extreme ambient temperatures of up to +60 °C.
Benefit from an extended operational range of the air conditioner PT 6500 HT via Duplex Cooling by connecting two heat exchangers of type PT S+ in series to the connecting line via DualHex coupling now instead of one heat exchanger.
For the air conditioner PT 6500 HT, Duplex Cooling enables a ΔT increase of the upper working range limit value by 5 °C.
With this technology, the air conditioner PT 6500 HT can even be used with ambient temperatures of up to +60 °C – or the device does not run under full load at lower temperatures.
For optional Duplex cooling operation, in addition to the DualHex coupling, an additional heat exchanger of the type PT S+ is required.
All air conditioners of the PT series by direct comparison:
To find the air conditioner PT which exactly meets your requirements, please consult the concise overview of all air conditioners of the PT series from Trotec, which we're providing to you here so that you can compare them directly to each other.
Models which you do not wish to include in your comparison can be easily dismissed with only one click.
A few practical benefits:
- Development, design, production: 100 % Trotec
- Particularly powerful compression refrigeration system, designed for use in T3 climate zone conditions with ambient temperatures from +7 to +55 °C
- Robust construction, specifically designed for mobile applications in the rental business
- Even larger rooms are cooled down quickly
- Simple installation without the need to consult specialists – ready for use in a matter of minutes
- Refrigerant-free heat removal from the internal unit to the heat exchanger
- Hot gas-controlled defrost unit for uninterrupted cooling operation
- Connection lines extendable to up to 30 m by use of quick-lock couplings for cooling remote and windowless rooms
Buy
![PT 6500 HT High Temperature Commercial Air Conditioner show in Trotec online shop](https://cdn.trotec.com/fit-in/1000x1000/filters:format(jpg)/en_GB/1210001072/High-Temperature-Commercial-Air-Conditioner-PT-6500-HT-153155-1680098188.jpg)
PT 6500 HT High Temperature Commercial Air Conditioner
8,199.95 £ incl. VAT Show net price (VAT not included)
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 1.210.001.072 | |
Type | ||
Split | ||
Monobloc | ||
Cooling capacity at 25 °C | ||
Cooling capacity [kW] | 5.5 | |
Cooling capacity [Btu/h] | 18,766 | |
Cooling capacity | ||
Max. cooling capacity [kW] | 6 | |
Max. cooling capacity [Btu/h] | 20,472 | |
Air flow rate | ||
Level Max. [m³/h] | 1,500 | |
Fan | ||
stages | 3 | |
Radial | ||
axial | ||
Attainable room temperature | ||
(min.) depending on operating conditions [°C] | 10 | |
Cooling medium | ||
Cooling medium | Water | |
Ambient conditions | ||
Min. temperature range [°C] | 10 | |
Max. temperature range [°C] | 45 | |
Electrical values | ||
Mains connection | 230 V, 50 Hz | |
Power input [kW] | 3 | |
Nominal current consumption [A] | 13 | |
Recommended fusing [A] | 32 | |
Electric connection | ||
Connection plug | CEE 7/7 | |
Compressor | ||
refrigerant | R-134a | |
Amount of refrigerant [g] | 1,000 | |
GWP factor | 1,430 | |
CO2 equivalent [t] | 1.43 | |
Pressure suction side [MPa] | 1.2 | |
Pressure outlet side [MPa] | 2.25 | |
Technical data external unit | ||
Power input [kW] | 0.18 | |
IP type of protection | IP44 | |
Surrounding conditions min. temperature [°C] | 7 | |
Surrounding conditions max. temperature [°C] | 55 | |
Sound level Level Max. - 3 m [dB(A)] | 65 | |
Heat dissipation | ||
External heat exchanger | ||
Closed water circuit | ||
Air | ||
hose length [m] | ||
Dimensions | ||
Length (packaging excluded) [mm] | 360 | |
Width (packaging excluded) [mm] | 815 | |
Height (packaging excluded) [mm] | 1,200 | |
Weight | ||
(packaging excluded) [kg] | 112 |
Equipment, features and functions | ||
---|---|---|
Condensate draining | ||
Automatic | ||
With water tank | ||
Exhaust air | ||
With condensate drain | ||
Room thermostat | ||
Available | ||
Room air filter | ||
Readily accessible | ||
Cleanable | ||
Additional functions | ||
Dehumidification function | ||
Heating function | ||
Ventilation function | ||
Automatic function | ||
Microprocessor-controlled operation | ||
Automatic fault diagnosis | ||
Room thermostat with temperature indication | ||
Operating hours counter | ||
Energy consumption meter (MID-compliant*) | ||
Temperature control | ||
Adjustable air discharge direction | ||
Quick coupling for the connection of internal and external unit | ||
Mobility | ||
Plastic wheels | ||
Carry/transport handle(s) | ||
Spot cooling | ||
Number of air outlets | ||
exhaust distributor max. [m] | ||
exhaust distributor | ||
exhaust distributor ø |
standard equipment
optionally available