Advice for private customers: +49 2452 962-450

Advice for business customers: +49 2452 962-400

Mon – Fri: 8:00 – 17:00 (CET)

TFV 300 Ex radial fan
  1. Products & Services
  2. Products ‑ HighPerformance
  3. Ventilation
  4. Ex-proof radial fans
  5. TFV 300 Ex

Radial fan TFV 300 Ex

The robust fan solution for high compression in ex-proof zones

Due to its great air transport capacity with high air pressure, the TFV 300 Ex is suitable for manifold ventilation applications in class 2 ex-proof zones, e.g. for tank cleaning, in docks, refineries, shafts or silos.

This high-quality device doesn’t mind aggressive surroundings, for the radial fan designed according to ATEX directive 2014/34/EU is integrated in a robust, powder-coated steel housing with highly resistant two-component finish. All desired steel grades are optionally available.

Even in case of long air transport routes with multiple arcs and hose distances of 40 metres the TFV 300 Ex impresses with a high air transport capacity. Because, in contrast to axial fans, this powerful radial fan conveys air vertically to the rotor axle according to the operating principle of a centrifuge, where air is pressed to the outside and condensed in a helical housing.

Switches, cables and plugs of the TFV 300 Ex are approved for use in explosion hazard conditions. Furthermore, appropriate connection plugs, approved for use in zones 1, 2, 21 and 22, are available for connection extensions.

In addition to the frameless standard version the TFV 300 Ex is optionally also available as depicted incl. additional frame made of galvanized steel and with robust wheels, forklift slots and crane lifting lugs. The transport frame offers maximum mobility and is optimally suited for use at frequently changing locations.

Connection plugs for application in ex-protection zones

Special connection plugs are optionally available for connection extensions of the ex-proof TFV models in explosion protection zones.

The adapter couplings are licensed for use in zones 1 and 2 (gas explosion protection) as well as zones 21 and 22 (dust explosion protection).

Adapter coupling 16 A Ex
Adapter coupling 16 A Ex

A few practical benefits:

  • Development, design, production: 100 % Trotec
  • Explosion group II, category 3G, temperature class 4
  • Robust high-quality unit “made in Germany” with a high conveying capacity
  • Splash-proof model (IP55)
  • Fan motor is situated outside of the main air current
  • Can be connected to both intake and exhaust ducts
  • Stable characteristics and constantly high pressure
  • Optionally also available for explosion group II, category 2G (zone 1), category 2D (zone 21) and category 3D (zone 2)

Air volume in proportion to channel length:

Air volume in proportion to channel length

Performance characteristics on the pressure side:

Performance characteristics on the pressure side
Technical data by comparison

All Ex-proof radial fans of the TFV series in direct comparison:

To find the Ex-proof radial fans of the TFV series which exactly meets your requirements, please consult the concise overview of all devices which we’re providing to you here so that you can compare them directly to each other.

Models which you do not wish to include in your comparison can be easily dismissed with only one click.

Technical data by comparison

Shop

TFV 300 Ex Radial Fan show in Trotec online shop

Technical data

Technical data
General information
  Article number 1.510.002.032
Air flow rate
  Air volume [m³/h] Level Max. - Freely blowing 7,000
Air volume at air pressure
  m³/h 5,000
  Pa 1,900
Air current
  Blowing out
  Sucking in
Air discharge velocity
  Air discharge speed [m/s] 27
  Air discharge speed [km/h] 97.2
Fan
  stages 1
Air pressure
  Level Max. [Pa] 2,800
Transport medium temperature
  max. [°C] 60
Ambient conditions
  Min. temperature range [°C] -20
  Max. temperature range [°C] 40
Safety feature
  IP type of protection IP55
Electrical values
  Mains connection 400 V, 50 Hz
  Power input [kW] 4
  Recommended fusing [A] 16
  Nominal current consumption [A] 8.6
Electric connection
  Connection plug CEE 16 A
  Provided by the customer
  Cable length [m]
Hose connection
  Suction nozzle [mm] 300
  Exhaust connection [mm] 450
Sound values
  Distance 1 m [dB(A)] 77
  Distance 3 m [dB(A)] 71
Explosion protection
  Zone 2
  Protection class II3G, T4
Dimensions
  Length (packaging excluded) [mm] 1,000
  Width (packaging excluded) [mm] 700
  Height (packaging excluded) [mm] 830
Weight
  (packaging excluded) [kg] 150
Equipment, features and functions
Housing design
  Steel
  Powder-coated
Mobility
  Crane
  Forklift
  Plastic wheels

 standard equipment

 optionally available

 not available

Accessories

Loading...

Alternative products

Loading...