Commercial air cleaner TAC 1500 S
The robust standard solution for clean air during restoration, reconstruction and expansion or painting work using airless paint spraying systems
Economic acquisition, powerful performance values and simple handling – these characteristics are combined in a robust metal construction of the air cleaner TAC 1500 S that is suitable for use on construction sites. Its Monoventic regulator enables you to steplessly adjust the air volume precisely to your actual needs, and the flexible filter system allows for the use of variable filter combinations for every construction site situation.
With the TAC 1500 S you can reliably filter coarse and fine dust or spray paint mist as well as concrete dust, fine sanding or plaster dust and highly dangerous quartz dusts or asbestos fibres.
The filter frame can be flexibly equipped with one or two filter elements, for example a G4 filter or an additional F7 filter, so that in combination with the HEPA filter a two- or three-stage air purification process in accordance with dust class H can be achieved. It is also possible to fit Trotec spray paint filters – ideal for an effective extraction of spray paint mists when using compressed-air or airless units.
TAC 1500 S – the ideal solution for dust-free sites
The TAC 1500 S is the economical solution for all users who do not want to do without the performance advantages of the professional air cleaner TAC 1500 on construction sites and during restoration work, but who neither want to use the device in hygienic areas nor in cleanroom environments.
For this purpose the Vario-shift function for terminal HEPA filters as well as the separate prefilter change indicator were omitted, while the air flow rates were kept completely identical to those of the TAC 1500 and can also be adjusted as needed via the infinitely adjustable Monoventic air volume control.
Typical air purification applications with the TAC 1500 S:
TAC 1500 and TAC 1500 S by comparison – application-oriented selection guide | TAC 1500 | TAC 1500 S |
Extraction of spray paint mists for spray painting or airless applications | ||
Dust extraction during construction work according to dust class M (occupational exposure limit > 0.1 mg/m³), for instance mineral wool dust, wood dust, lead dust | ||
Dust extraction during restoration work according to dust class H (occupational exposure limit < 0.1 mg/m³), for instance mould spores, mineral fibres, bitumen, quartz dust, asbestos (observe TRGS 519) | ||
Air purification during work in hygienic areas* according to dust class H, for example hospitals, laboratories, doctors' offices | — | |
Air purification during work in cleanroom environments* | — | |
* terminal HEPA filter required according to dust class H; separate prefilter control device recommended in addition to main filter control device. |
A few practical benefits:
- Professional quality "made in Germany" – originally produced by Trotec
- Versatile filter system for the extraction of dust and spray paint mists
- Dust class H, approvable for asbestos abatement as per TRGS 519
- Enormously robust and stackable metal housing
- Powerful premium fan
- Monoventic regulator for precise and infinitely adjustable amounts of air
- Visual and acoustic filter change indicator
- Operating hours counter
- Low-maintenance, stackable construction with quick release fasteners for simple filter change
Recommendation for filter combinations specific to the application and corresponding room size suitability
TAC air cleaner | TAC 750 E | TAC 1500 S | TAC 1500 | TAC 3000 | TAC 5000 | TAC 6500 | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Field of application | Filter combination | Suitable for rooms to a size of ¹ | |||||||||||
m³ | m² | m³ | m² | m³ | m² | m³ | m² | m³ | m² | m³ | m² | ||
Coarse dust ² (≤ 3 LW/h ⁶) |
G4 | 250 | 100 | 220 | 88 | 220 | 88 | 500 | 200 | 1,200 | 480 | 1,400 | 560 |
Fine particulates ³ (≤ 3 LW/h ⁶) |
G4 + F7 to F9 | – | – | 110 | 44 | 110 | 44 | 270 | 108 | 600 | 240 | 750 | 300 |
Suspended matter ⁴ (≥ 10 LW/h ⁶) |
G4 + H13/H14 | 25 | 10 | 50 | 20 | 50 | 20 | 100 | 40 | 150 | 60 | 200 | 80 |
Hygienic areas ⁵ (≥ 15 LW/h ⁶) |
G4 + H13/H14 | 12.5 | 5 | 35 | 14 | 35 | 14 | 70 | 28 | 110 | 44 | 135 | 54 |
¹ With an assumed room height of 2.5 m; ² Typical coarse dust tasks: sawing, filing; ³ Typical fine dust tasks: restoration works with materials containing minerals or glass wool; ⁴ Typical suspended matter tasks: grinding, asbestos abatement or mould remediation, mineral dusts etc.; ⁵ H13/H14 downstream; ⁶ Air exchange per hour |
Virus filtering also possible now!
For the H13 HEPA filter compartment of all professional air cleaners of the TAC series, as of now also high-performance filters of the class H14 are available as consumables for virus filtering.
These final filters for cleanrooms of classes ISO 4 and ISO 3 feature a separation efficiency of 99.995% at a particle size of 0.1 to 0.2 µm.
Viral strains such as SARS-CoV, MERS-CoV or SARS-CoV-2 (Covid-19) show similar particle sizes, recent studies for example specify the particle size of the coronavirus to 120 to 160 nanometres, i.e. 0.12 to 0.16 µm.
Such particle sizes can be effectively separated by means of the H14 filters, especially since viruses in the air generally occur in combination with saliva or suspended matters as larger conglomerates.
Trotec: Innovation made in Germany
Take a look behind the scenes: As one of the internationally leading manufacturers of air treatment solutions, Trotec offers industrial and commercial customers innovative products for air purification, dehumidification, heating, air conditioning and ventilation. We rely 100 % on research, development, design and production in Germany for our high-performance devices. For the highest quality requirements, sophisticated system solutions and fresh ideas.
Buy
TAC 1500 S Air Purifier
949.95 £ incl. VAT Show net price (VAT not included)
Technical data
Technical data | ||
---|---|---|
General information | ||
Article number | 1.580.000.104 | |
Dust class | ||
as per DIN EN 60335-2-69 | H | |
Air flow rate | ||
Max. air volume flow [m³/h] | 1,000 | |
Negative static pressure [Pa] | 900 | |
Recommended amount of air for filter class H [m³/h] | 500 | |
Air volume with filter surface H13 > [m²] | 4.25 | |
Vario-shift function | ||
For variable filter configuration | ||
Electrical values | ||
Mains connection | 230 V, 50/60 Hz | |
Power input [kW] | 0.175 | |
Nominal current consumption [A] | 1.4 | |
Recommended fusing [A] | 10 | |
Electric connection | ||
Connection plug | CEE 7/7, H05RN-F | |
Cable length [m] | 3 | |
Air transport hose connector | ||
Suction side ø [mm] | 200 | |
Blow-out side ø [mm] | 200 | |
Sound values | ||
Distance 1 m [dB(A)] | 65 | |
Fan | ||
Radial | ||
stages | Infinitely variable | |
Dimensions | ||
Length (packaging excluded) [mm] | 610 | |
Width (packaging excluded) [mm] | 360 | |
Height (packaging excluded) [mm] | 400 | |
Weight | ||
(packaging excluded) [kg] | 15 |
Equipment, features and functions | ||
---|---|---|
Equipment | ||
Infinite adjustment of air volume | ||
FlowMatic regulation of air volume | ||
Thermal filter decontamination | ||
Filter change indication | ||
Pre-filter | ||
Main filter | ||
Filter | ||
combination Coarse dust (≤ 3 ACH) | G4 | |
Suitable for rooms sized up to Coarse dust (≤ 3 ACH) [m³] | 220 | |
combination Fine particulates (≤ 3 ACH) | G4 + F7 / F9 | |
Suitable for rooms sized up to Fine particulates (≤ 3 ACH) [m³] | 110 | |
combination Suspended matter (≥ 10 ACH) | G4 + H13 | |
Suitable for rooms sized up to Suspended matter (≥ 10 ACH) [m³] | 50 | |
Mobility | ||
Carry/transport handle(s) | ||
Non-marking rubber feet | ||
stackable | ||
Full-rubber guide wheels | ||
Guiding wheels pneumatic tyres | ||
Stacking frame | ||
Forklift pockets | ||
Shock protection frame | ||
Swivel casters with parking brakes | ||
Non-marking rubber wheels/rollers | ||
Trestle rollers/ fixed castors |
standard equipment
optionally available
not available