TKL service for you:
Capacity Calculation
direct to calculation »
Unique in Europe!!
TKL for sublessors
Let us inform you about the multifaceted benefits of cooperation.
Dehumidifier TTK 175 S
Article number: 1120001053Details
Technical data | ||
---|---|---|
General information | ||
Article number | 1.120.001.053 | |
Dehumidification performance | ||
At 20 °C / 60 % RH [l/24h] | 18 | |
At 30 °C / 80 % RH [l/24h] | 40 | |
Max. [l/24h] | 50 | |
Air flow rate | ||
Level Max. | 580 | |
Recommended room size construction drying | ||
m³ | 225 | |
m² | 90 | |
Recommended room size dry keeping | ||
m³ | 450 | |
m² | 180 | |
Ambient conditions | ||
Min. temperature range [°C] | 5 | |
Max. temperature range [°C] | 32 | |
Min. humidity range [% RH] | 50 | |
Max. humidity range [% RH] | 90 | |
Electrical values | ||
Mains connection | 220 - 240 V, 50 Hz | |
Nominal current consumption [A] | 2.8 | |
Power input [kW] | 0.6 | |
Recommended fusing [A] | 10 | |
Electric connection | ||
Connection plug | CEE 7/7 | |
Cable length [m] | 3 | |
Compressor | ||
Rotary piston compressor | ||
refrigerant | R-410A | |
Amount of refrigerant [g] | 150 | |
GWP factor | 3 | |
CO2 equivalent | 0.00045 t | |
Pressure suction side [MPa] | 0.6 | |
Pressure outlet side [MPa] | 2.1 | |
Max. permissible pressure [Mpa] | 3 | |
Water tank | ||
Contents in [Litres] | 6 | |
Sound values | ||
Distance 1 m [dB(A)] | 52 | |
Functions and features | ||
Automatic fault diagnosis system | ||
Operating control lamp | ||
Room temperature sensor | ||
Automatic switch-off | ||
Operating button for draining residual water | ||
Auto restart function | ||
Connection for external condensate drain | ||
Memory function | ||
Fan rundown function | ||
Dimensions | ||
Length (packaging excluded) [mm] | 390 | |
Width (packaging excluded) [mm] | 380 | |
Height (packaging excluded) [mm] | 643 | |
Weight | ||
(packaging excluded) [kg] | 35 |
standard equipment
optionally available
not available
Combination products
Loading...
Accessories
Loading...