| Technical data |
| Article number |
3.510.205.095
|
3.510.205.098
|
3.510.006.010
|
3.510.006.011
|
3.510.006.015
|
3.510.006.016
|
| Number of channels |
2
|
2
|
6
|
6
|
6
|
6
|
| Channel sizes |
2,5 µm, 10 µm
|
2.5 µm, 10 µm
|
0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm
|
0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm
|
0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm
|
0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10.0 µm
|
| Detector type |
Light-scattering measurement
|
Light scattering
|
Light-scattering measurement
|
Light-scattering measurement
|
Light-scattering measurement
|
Light-scattering measurement
|
| Counting modes |
|
Cumulative
|
Concentration, cumulative, differential
|
Concentration, cumulative, differential
|
Concentration, cumulative, differential
|
Concentration, cumulative, differential
|
| Counting efficiency |
|
100%
|
50 % at 0.3 µm; 100 % for particles > 0.45 µm
|
50 % at 0.3 µm; 100 % for particles > 0.45 µm
|
50 % at 0.3 µm, 100 % for particles > 0.45 µm
|
50 % at 0.3 µm, 100 % for particles > 0.45 µm
|
| Flow rate |
|
|
2.83 l/m (0.1 ft³/min), controlled by internal pump
|
2.83 l/m (0.1 ft³/min), controlled by internal pump
|
2.83 l/min (0.1 ft³/min), controlled by internal pump
|
2.83 l/min (0.1 ft³/min), controlled by internal pump
|
| Zero count |
|
|
< 1 particle / 5 min
|
< 1 particle / 5 min
|
< 1 particle / 5 min
|
< 1 particle / 5 min
|
| Coincidence loss |
|
|
5 %, 2 million particles per ft³ (28.3 litres)
|
5 %, 2 million particles per ft³ (28.3 litres)
|
5 %, 2 million particles per ft³ (28.3 litres)
|
5 %, 2 million particles per ft³ (28.3 litres)
|
| Sample inlet |
|
|
Isokinetic probe
|
Isokinetic probe
|
Isokinetic probe
|
Isokinetic probe
|
| Particle mass conversion |
2.5 µm, 10 µm
|
|
|
|
2.5 µm, 10 µm
|
2.5 µm, 10 µm
|
| Min. measuring range | Particle mass conversion [µg/m³] |
0
|
0
|
|
|
0
|
0
|
| Max. measuring range | Particle mass conversion [µg/m³] |
2,000
|
2,000
|
|
|
2,000
|
2,000
|
| Resolution | Particle mass conversion [µg/m³] |
1
|
1
|
|
|
1
|
|
| Min. measuring range | Formaldehyde [ppm] |
|
|
|
|
0.01
|
0.01
|
| Max. measuring range | Formaldehyde [ppm] |
|
|
|
|
5
|
5
|
| Accuracy ± | Formaldehyde [%] |
|
|
|
|
5
|
5
|
| Resolution | Formaldehyde [ppm] |
|
|
|
|
1
|
1
|
| Min. measuring range | Carbon monoxide [ppm] |
|
0
|
|
|
|
|
| Max. measuring range | Carbon dioxide [ppm] |
|
9,999
|
|
|
|
|
| Accuracy ± | Carbon monoxide [%] |
|
5
|
|
|
|
|
| Resolution | Carbon monoxide [ppm] |
|
1
|
|
|
|
|
| Min. measuring range | Carbon monoxide [ppm] |
|
|
|
|
10
|
10
|
| Max. measuring range | Carbon dioxide [ppm] |
|
|
|
|
1,000
|
1,000
|
| Accuracy ± | Carbon monoxide [%] |
|
|
|
|
5
|
5
|
| Resolution [ppm] | Carbon monoxide |
|
|
|
|
1
|
1
|
| Min. measuring range | Air temperature [°C] |
0
|
-20
|
0
|
0
|
0
|
0
|
| Max. measuring range | Air temperature [°C] |
50
|
70
|
50
|
50
|
50
|
50
|
| Min. measuring range | Air temperature [°F] |
32
|
-4
|
32
|
32
|
32
|
32
|
| Max. measuring range | Air temperature [°F] |
122
|
158
|
122
|
122
|
122
|
122
|
| Resolution [°C] |
0.1
|
0.1
|
|
|
|
|
| Resolution [°F] |
0.1
|
0.1
|
|
|
|
|
| Temperature below 10 °C - Temperature above 40 °C [°C] |
|
|
1
|
1
|
1
|
1
|
| Temperature below 50 °F - Temperature above 104 °F [°F] |
|
|
1.8
|
1.8
|
1.8
|
1.8
|
| Accuracy ± 0 °C - 50 °C [°C] |
1
|
|
|
|
|
|
| Accuracy [°C] |
|
2
|
|
|
|
|
| Accuracy ± 10 °C - 40 °C [°C] |
|
|
0.5
|
0.5
|
0.5
|
0.5
|
| Accuracy ± 32 °F - 122 °F [°F] |
2
|
|
|
|
|
|
| Accuracy ± 50 °F - 104 °F [°F] |
|
|
0.9
|
0.9
|
0.9
|
0.9
|
| Min. measuring range | Relative humidity [%] |
0
|
|
0
|
0
|
0
|
0
|
| Max. measuring range | Relative humidity [%] |
100
|
|
100
|
100
|
100
|
100
|
| Display resolution [%RH] |
0.1
|
0.1
|
|
|
|
|
| Min. measuring range | Relative humidity [%RH] |
|
0
|
|
|
|
|
| Max. measuring range | Relative humidity [%RH] |
|
100
|
|
|
|
|
| Accuracy 0 % - 20 % [%] |
5
|
5
|
5
|
5
|
5
|
5
|
| Accuracy 20 % - 80 % [%] |
3.5
|
3.5
|
|
|
|
|
| Accuracy 80 % - 100 % [%] |
5
|
5
|
5
|
5
|
5
|
5
|
| Accuracy 40 % - 60 % [%] |
|
|
3
|
3
|
3
|
3
|
| Accuracy 20 % - 40 % [%] |
|
|
3.5
|
3.5
|
3.5
|
3.5
|
| Accuracy 60 % - 80 % [%] |
|
|
3.5
|
3.5
|
3.5
|
3.5
|
| Min. measuring range | Dew point temperature [°C] |
|
|
0
|
0
|
0
|
0
|
| Max. measuring range | Dew point temperature [°C] |
|
|
50
|
50
|
50
|
50
|
| Min. measuring range | Dew point temperature [°F] |
|
|
32
|
32
|
32
|
32
|
| Max. measuring range | Dew point temperature [°F] |
|
|
122
|
122
|
122
|
122
|
| Accuracy ± 10 °C - 40 °C [°C] |
|
|
1
|
1
|
1
|
1
|
| Accuracy ± 50 °F - 104 °F [°F] |
|
|
1.8
|
1.8
|
1.8
|
1.8
|
| Min. measuring range | Wet-bulb temperature [°C] |
|
|
0
|
0
|
0
|
0
|
| Max. measuring range | Wet-bulb temperature [°C] |
|
|
80
|
80
|
80
|
80
|
| Min. measuring range | Wet-bulb temperature [°F] |
|
|
32
|
32
|
32
|
32
|
| Max. measuring range | Wet-bulb temperature [°F] |
|
|
176
|
176
|
176
|
176
|
| Accuracy ± | Wet-bulb temperature [°C] |
|
|
1
|
1
|
1
|
1
|
| Accuracy ± | Wet-bulb temperature [°F] |
|
|
1.8
|
1.8
|
1.8
|
1.8
|
| TFT colour LCD 2.0" |
|
|
|
|
|
|
| 220 x 176 px |
|
|
|
|
|
|
| 3" TFT LCD display |
|
|
|
|
|
|
| LCD |
|
|
|
|
|
|
| Colour |
|
|
|
|
|
|
| Monochrome |
|
|
|
|
|
|
| Touch |
|
|
|
|
|
|
| Internal flash memory |
5,000 measurements
|
Internal flash memory
|
Up to 5,000 data records
|
Up to 5,000 data records
|
Up to 5,000 data records
|
Up to 5,000 data records
|
| Extended data memory (microSD, optional) - (max. 16 GB) |
|
|
|
|
|
|
| Photo storage format |
|
|
JPEG (640 x 480)
|
JPEG (640 x 480)
|
JPEG (640 x 480)
|
JPEG (640 x 480)
|
| Video storage format |
|
|
3GP (320 x 240)
|
3GP (320 x 240)
|
3GP (320 x 240)
|
3GP (320 x 240)
|
| Bluetooth |
|
|
|
|
|
|
| USB |
|
|
|
|
|
|
| 3.5 headphone jack |
|
|
|
|
|
|
| 3.5 mm audio jack (headphones) |
|
|
|
|
|
|
| Internal battery (Li-ion) |
|
|
|
|
|
|
| Via mains voltage |
|
|
|
|
|
|
| Battery type |
|
1 x 3.7 V lithium polymer battery
|
Polymer LI-ION battery
|
Polymer LI-ION battery
|
Polymer LI-ION battery
|
Polymer LI-ION battery
|
| Internal (battery) |
|
|
|
|
|
|
| External (power adapter) |
|
|
|
|
|
|
| External (USB) |
|
|
|
|
|
|
| Approx. 4 hours of continuous operation |
|
|
|
|
|
|
| > 30 h |
|
|
|
|
|
|
| Approx. 2 hours with connected AC adapter |
|
|
|
|
|
|
| Plastics |
|
|
|
|
|
|
| Metal |
|
|
|
|
|
|
| Operation - min. temperature [°C] |
0
|
0
|
0
|
0
|
0
|
0
|
| Operation - max. temperature [°C] |
40
|
50
|
50
|
50
|
50
|
50
|
| Operation – max. relative humidity (non-condensing) [%] |
80
|
100
|
80
|
80
|
80
|
80
|
| Storage - min. temperature [°C] |
-10
|
|
-10
|
-10
|
-10
|
-10
|
| Storage - max. temperature [°C] |
50
|
|
60
|
60
|
60
|
60
|
| Storage - max. relative humidity [%] |
90
|
|
|
|
|
|
| Length (packaging excluded) [mm] |
188
|
85
|
240
|
240
|
|
240
|
| Width (packaging excluded) [mm] |
35
|
75
|
58
|
58
|
|
58
|
| Height (packaging excluded) [mm] |
52
|
155
|
75
|
75
|
|
75
|
| (packaging excluded) [kg] |
0.175
|
0.36
|
0.435
|
0.435
|
0.435
|
0.435
|
| Standard scope of delivery |
| Measuring device |
|
|
|
|
|
|
| Li-ion battery (integrated) |
|
|
|
|
|
|
| Wire stand |
|
|
|
|
|
|
| Mini USB cable |
|
|
|
|
|
|
| Charger (USB 5 V, 1 A) |
|
|
|
|
|
|
| Getting started guide |
|
|
|
|
|
|
| Battery(-ies) |
|
|
|
|
|
|
| Lithium polymer battery |
|
|
|
|
|
|
| Operating manual |
|
|
|
|
|
|
| Charger |
|
|
|
|
|
|
| Zero filter with connection hose |
|
|
|
|
|
|
| Mini tripod |
|
|
|
|
|
|
| Transport case |
|
|
|
|
|
|
| USB cable |
|
|
|
|
|
|
| Software |
|
|
|
|
|
|
| Calibration certificate |
|
|
|
|
|
|
| Ascertainable measured values and functions |
| Particle concentration [n/l] |
|
|
|
|
|
|
| Dew point temperature [°F] |
|
|
|
|
|
|
| Sound [dBC] |
|
|
|
|
|
|
| Sound [dBA] |
|
|
|
|
|
|
| Microwave radiation [mW/cm²] |
|
|
|
|
|
|
| Light [lx] |
|
|
|
|
|
|
| Light [fc] |
|
|
|
|
|
|
| Carbon monoxide [ppm] |
|
|
|
|
|
|
| Combustible gases [indicativeviaacousticsignaldependingontheconcentration] |
|
|
|
|
|
|
| Wet-bulb temperature [°F] |
|
|
|
|
|
|
| Wet-bulb temperature [°C] |
|
|
|
|
|
|
| Air temperature [°C] |
|
|
|
|
|
|
| Dew point temperature [°C] |
|
|
|
|
|
|
| Particle concentration [n/m³] |
|
|
|
|
|
|
| Temperature [°F] |
|
|
|
|
|
|
| Temperature [°C] |
|
|
|
|
|
|
| CO2 |
|
|
|
|
|
|
| Mass concentration PM2.5/PM10 |
|
|
|
|
|
|
| Relative humidity [%] |
|
|
|
|
|
|
| Air temperature [°F] |
|
|
|
|
|
|
| HCHO [ppm] |
|
|
|
|
|
|
| Simultaneous measurement PM2.5 and PM10 |
|
|
|
|
|
|
| Calibration option |
|
|
|
|
|
|
| Average value display |
|
|
|
|
|
|
| Language selection |
|
|
|
|
|
|
| °C/°F switching |
|
|
|
|
|
|
| Photo recording |
|
|
|
|
|
|
| Video recording |
|
|
|
|
|
|
| Automatic display switch-off - (90 seconds, 2 minutes or 4 minutes) |
|
|
|
|
|
|
| 4-digit measuring value display |
|
|
|
|
|
|
| Measured value hold function |
|
|
|
|
|
|
| A/C frequency weighting |
|
|
|
|
|
|
| Limit value alarm |
|
|
|
|
|
|
| Light detector |
|
|
|
|
|
|
| Microphone |
|
|
|
|
|
|
| Gooseneck probe |
|
|
|
|
|
|
| Automatic display switch-off |
|
|
|
|
|
|
| Calibration function |
|
|
|
|
|
|
| Reversible time weighting |
|
|
|
|
|
|
| Minimum value display |
|
|
|
|
|
|
| Bar graph indicator |
|
|
|
|
|
|
| Integrated foot |
|
|
|
|
|
|
| Switching function °C/°F |
|
|
|
|
|
|
| Memory for 5,000 measured values |
|
|
|
|
|
|
| Bluetooth interface |
|
|
|
|
|
|
| Automatic switch-off |
|
|
|
|
|
|
| Time |
|
|
|
|
|
|
| Battery status indication |
|
|
|
|
|
|
| ¼ inch tripod thread |
|
|
|
|
|
|
| Automatically alternating indication of all measured climate parameters |
|
|
|
|
|
|
| Maximum value display |
|
|
|
|
|
|
| Measurement of temperature, relative humidity, CO2, configurable measuring rate, optional XY-diagram |
|
|
|
|
|
|
| Automatic Baseline Calibration |
|
|
|
|
|
|
| Visual alarm function |
|
|
|
|
|
|
| Acoustic alarm function |
|
|
|
|
|
|
| Date |
|
|
|
|
|
|
| Adjustable display brightness |
|
|
|
|
|
|
| Display illumination |
|
|
|
|
|
|
| Backlit display |
|
|
|
|
|
|