| Technical data |
| Article number |
3.510.205.075
|
3.510.205.077
|
| Functional principle | Layer thickness |
Magnetic induction, Turbulent flow
|
Magnetic induction, Turbulent flow
|
| Material | Layer thickness |
Ferromagnetic ground, Non-ferrous metal ground
|
Ferromagnetic ground, Non-ferrous metal ground
|
| Critical primary layer thickness of ferromagnetic ground |
0.5 µm
|
0.5 µm
|
| Minimum bending radius of the measuring surface with ferromagnetic ground |
1.5 mm
|
1.5 mm
|
| Minimum measuring surface with ferromagnetic ground |
Ø 7 mm
|
Ø 7 mm
|
| Critical primary layer thickness of non-ferrous metal ground |
0.3 µm
|
0.3 µm
|
| Minimum bending radius with non-ferrous metal ground |
3 mm
|
3 mm
|
| Minimum measuring surface with non-ferrous metal ground |
Ø 5 mm
|
Ø 5 mm
|
| Accuracy |
±0.1 µm
|
±0.1 µm (at 0 µm up to 100 µm) ±1 µm (at 100 µm up to 1,000 µm) ±0.01 mm (at 1,000 µm up to 2,000 µm)
|
| Max. measuring range [µm] |
1,250
|
2,000
|
| Min. measuring range [µm] |
0
|
0
|
| Tolerance | Ferromagnetic ground In the measuring range from 850 to 1,250 µm |
±5 % of measured value
|
|
| Tolerance | Ferromagnetic ground In the measuring range from 0 to 850 µm |
(±3 % + 1) µm of measured value
|
|
| Tolerance | Non-ferrous metal ground Guaranteed tolerance with non-ferrous metal ground in the measuring range from 850 to 1,250 µm |
±5 % of measured value
|
|
| Tolerance | Non-ferrous metal ground Guaranteed tolerance with ferromagnetic ground in the measuring range from 0 to 850 µm |
(±3 % + 1.5) µm of measured value
|
|
| Tolerance | Non-ferrous metal ground Guaranteed tolerance with non-ferrous metal ground in the measuring range from 0 to 1,000 µm |
|
(±2 % + 2) µm of measured value
|
| Tolerance | Non-ferrous metal ground Guaranteed tolerance with non-ferrous metal ground in the measuring range from 1,000 to 2,000 µm |
|
±3.5 % µm of measured value
|
| Tolerance | Ferromagnetic ground Guaranteed tolerance with ferromagnetic ground in the measuring range from 0 to 1,000 µm |
|
(±2 % + 2) µm of measured value
|
| Tolerance | Ferromagnetic ground Guaranteed tolerance with ferromagnetic ground in the measuring range from 1,000 to 2,000 µm |
|
±3.5 % µm of measured value
|
| Internal flash memory |
Up to 400 measured values
|
Up to 2,500 measured values
|
| Recall of previous measurements |
|
|
| LCD |
|
|
| Monochrome |
|
|
| Push buttons |
|
|
| Operation - min. temperature [°C] |
0
|
0
|
| Operation - max. temperature [°C] |
40
|
40
|
| Operation – min. relative humidity [%r.F.] |
20
|
20
|
| Operation - max. relative humidity [%r.F.] |
90
|
90
|
| Length (packaging excluded) [mm] |
110
|
114
|
| Width (packaging excluded) [mm] |
24
|
27
|
| Height (packaging excluded) [mm] |
54
|
54
|
| (packaging excluded) [kg] |
0.114
|
0.152
|
| Standard scope of delivery |
| Measuring device |
|
|
| Transport case |
|
|
| USB cable |
|
|
| Software |
|
|
| Calibration accessories |
|
|
| Operating manual |
|
|
| Cable extension for probe |
|
|
| Ascertainable measured values and functions |
| Layer thickness [µm] |
|
|
| Minimum value display |
|
|
| Maximum value display |
|
|
| Average value display |
|
|
| Automatic switch-off |
|
|
| Backlit display |
|
|
| Acoustic alarm function |
|
|
| Sensor for ferromagnetic ground |
|
|
| Sensor for non-ferrous metal ground |
|
|
| Two-point calibration |
|
|
| Standard deviation |
|
|
| Battery status indication |
|
|
| Error indicator for incorrect measuring |
|
|
| Bluetooth |
|
|