Any questions?

We are happy to provide further information available.

Business: +49 2452 962 400
Industry: +49 2452 962 777
End-consumers: +49 2452 962 450

SDI sensors for climate measuring

T3000 display climate measurement

All SDI climate sensors allow to accurately measure air temperature, dew point temperature, mixing ratio as well as relative and absolute humidity.

During measurement, air temperature, humidity and dew point temperature values can be simultaneously shown in real time on the T3000 display.

Minimum, maximum, average and “hold” values can be displayed optionally in addition to these three measured values at the bottom of the display.

Thanks to the integrated logger function of the T3000 you can also conduct 5-, 10-, 30- or 60-minute non-stop measurements while recording all climate values.

Critical dew point
Critical dew point

Critical dew point

Practice-oriented measurement parameter to contain damages caused by moisture or mould

Condensation of air moisture on objects with surface temperatures close to or below dew point encourages mould growth in the extreme.

Yet, critical climate conditions conducive to the formation of mould already prevail long before reaching the dew point. ­

Hence the T3000 comes equipped with not only a dew point recognition but also with a measuring function to determine the "critical dew point". It defines the temperature which with respect to a specific humidity level (70, 75 and 80 % RH preselectable) is to be regarded as critical for mould formation.

Especially for the damage analysis in environments with otherwise inconspicuous room climate values it is important to know the critical dew point, e.g. for measurements behind picture frames, closets or wardrobes.

T3000 sensors for climate measuring
Room climate measurements using the T3000

Climate sensor TS 210 SDI

TS 210 SDI Climate Sensor show in Trotec online shop

TS 210 SDI Climate Sensor

For measuring the relative humidity and air temperature. Relative humidity (r.h.), absolute humidity (g/m³), air temperature (°C, °F) and dew point temperature (dp °C, dp °F).

213.95 £ incl. VAT
Show net price (VAT not included)

buy

Technical data
General information
  Article number 3.510.220.210
Air temperature [°C]
  Min. measuring range [°C] -20
  Max. measuring range [°C] 50
  Resolution [°C] 0.1
  Accuracy ± -10 °C - 50 °C [°C] 0.4
  Accuracy ± -20 °C - -10 °C [°C] 0.5
  Measuring principle NTC
Humidity [%]
  Min. measuring range [%] 0
  Max. measuring range [%] 95
  Resolution [%] 0.1
  Accuracy 0 % - 90 % [%] 2
  Accuracy 90 % - 100 % [%] 3
  Measuring principle Capacitive
Interfaces / plug design
  Plug design SDI connector
Dimensions of sensor element
  Length [mm] 108
  Diameter [mm] 12
Material of sensor element
  Polycarbonate
  Aluminium
  Stainless steel
  Composite
  Other
Material of handle
  Material Plastic
  Plastic/metal
  Metal
Ascertainable measured values and functions
Internal sensors
  Dew point temperature [°F]
  Absolute humidity content [g/m³]
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Dew point temperature [°C]
  Mixing ratio [g/kg]
Functions and features
  Stainless steel probe
  High-temperature resistant (briefly to up to 180°C!)
  Metal grid filter (gauze) for sensor protection
  Suitable for cleanrooms
  Teflon filter for sensor protection

 standard equipment

 optionally available

 not available

Climate sensor TS 230 SDI

TS 230 SDI Climate Sensor show in Trotec online shop

TS 230 SDI Climate Sensor

Thanks to its length of 250 mm and 12 mm diameter you can reach and adequately investigate areas that are difficult to access. Of course you also benefit from advantages like a high measurement accuracy and resolution at this model .

641.85 £ incl. VAT
Show net price (VAT not included)

buy

Technical data
General information
  Article number 3.510.220.220
Air temperature [°C]
  Min. measuring range [°C] -40
  Max. measuring range [°C] 140
  Max. measuring range briefly [°C] 180
  Resolution [°C] 0.1
  Accuracy ± -40 °C - 140 °C [°C] 0.7
  Measuring principle PT100
Humidity [%]
  Min. measuring range [%] 0
  Max. measuring range [%] 100
  Resolution [%] 0.1
  Accuracy 0 % - 90 % [%] 2
  Accuracy 90 % - 100 % [%] 3
  Measuring principle Capacitive
Interfaces / plug design
  Plug design SDI connector
Dimensions of sensor element
  Length [mm] 250
  Diameter [mm] 12
Material of sensor element
  Stainless steel
  Aluminium
  Composite
  Polycarbonate
  Other
Material of handle
  Material Plastic
  Plastic/metal
  Metal
Ascertainable measured values and functions
Internal sensors
  Dew point temperature [°F]
  Absolute humidity content [g/m³]
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Dew point temperature [°C]
  Mixing ratio [g/kg]
Functions and features
  Stainless steel probe
  High-temperature resistant (briefly to up to 180°C!)
  Metal grid filter (gauze) for sensor protection
  Suitable for cleanrooms
  Teflon filter for sensor protection

 standard equipment

 optionally available

 not available

Climate sensor TS 250 SDI

TS 250 SDI Climate Sensor show in Trotec online shop

TS 250 SDI Climate Sensor

Thanks to its length of 250 mm and 5 mm diameter you can reach and adequately investigate areas that are difficult to access. Of course you also benefit from advantages like a high measurement accuracy and resolution at this model.

504.70 £ incl. VAT
Show net price (VAT not included)

buy

Technical data
General information
  Article number 3.510.220.235
Air temperature [°C]
  Min. measuring range [°C] -40
  Max. measuring range [°C] 100
  Resolution [°C] 0.1
  Accuracy ± -40 °C - 100 °C [°C] 0.7
  Measuring principle PT100
Humidity [%]
  Min. measuring range [%] 0
  Max. measuring range [%] 100
  Resolution [%] 0.1
  Accuracy ± [% RH] 2
Interfaces / plug design
  Plug design SDI connector
Dimensions of sensor element
  Length [mm] 250
  Diameter [mm] 5
Material of sensor element
  Stainless steel
  Aluminium
  Composite
  Polycarbonate
  Other
Material of handle
  Material Plastic
  Plastic/metal
  Metal
Ascertainable measured values and functions
Internal sensors
  Dew point temperature [°F]
  Absolute humidity content [g/m³]
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Dew point temperature [°C]
  Mixing ratio [g/kg]
Functions and features
  Stainless steel probe
  High-temperature resistant (briefly to up to 180°C!)
  Metal grid filter (gauze) for sensor protection
  Suitable for cleanrooms
  Teflon filter for sensor protection

 standard equipment

 optionally available

 not available