Technical data
General information
Article number 3.510.205.075 3.510.205.077
Layer thickness measurement
Functional principle | Layer thickness Magnetic induction, Turbulent flow Magnetic induction, Turbulent flow
Material | Layer thickness Ferromagnetic ground, Non-ferrous metal ground Ferromagnetic ground, Non-ferrous metal ground
Critical primary layer thickness of ferromagnetic ground 0.5 µm 0.5 µm
Minimum bending radius of the measuring surface with ferromagnetic ground 1.5 mm 1.5 mm
Minimum measuring surface with ferromagnetic ground Ø 7 mm Ø 7 mm
Critical primary layer thickness of non-ferrous metal ground 0.3 µm 0.3 µm
Minimum bending radius with non-ferrous metal ground 3 mm 3 mm
Minimum measuring surface with non-ferrous metal ground Ø 5 mm Ø 5 mm
Accuracy ±0.1 µm ±0.1 µm (at 0 µm up to 100 µm)
±1 µm (at 100 µm up to 1,000 µm)
±0.01 mm (at 1,000 µm up to 2,000 µm)
Max. measuring range [µm] 1,250 2,000
Min. measuring range [µm] 0 0
Tolerance | Ferromagnetic ground In the measuring range from 850 to 1,250 µm ±5 % of measured value
Tolerance | Ferromagnetic ground In the measuring range from 0 to 850 µm (±3 % + 1) µm of measured value
Tolerance | Non-ferrous metal ground Guaranteed tolerance with non-ferrous metal ground in the measuring range from 850 to 1,250 µm ±5 % of measured value
Tolerance | Non-ferrous metal ground Guaranteed tolerance with ferromagnetic ground in the measuring range from 0 to 850 µm (±3 % + 1.5) µm of measured value
Tolerance | Non-ferrous metal ground Guaranteed tolerance with non-ferrous metal ground in the measuring range from 0 to 1,000 µm (±2 % + 2) µm of measured value
Tolerance | Non-ferrous metal ground Guaranteed tolerance with non-ferrous metal ground in the measuring range from 1,000 to 2,000 µm ±3.5 % µm of measured value
Tolerance | Ferromagnetic ground Guaranteed tolerance with ferromagnetic ground in the measuring range from 0 to 1,000 µm (±2 % + 2) µm of measured value
Tolerance | Ferromagnetic ground Guaranteed tolerance with ferromagnetic ground in the measuring range from 1,000 to 2,000 µm ±3.5 % µm of measured value
Memory organisation
Internal flash memory Up to 400 measured values Up to 2,500 measured values
Recall of previous measurements
Display
LCD
Monochrome
Device control
Push buttons
Ambient conditions
Operation - min. temperature [°C] 0 0
Operation - max. temperature [°C] 40 40
Operation – min. relative humidity [%r.F.] 20 20
Operation - max. relative humidity [%r.F.] 90 90
Dimensions
Length (packaging excluded) [mm] 110 114
Width (packaging excluded) [mm] 24 27
Height (packaging excluded) [mm] 54 54
Weight
(packaging excluded) [kg] 0.114 0.152
Standard scope of delivery
Standard scope of delivery
Measuring device
Transport case
USB cable
Software
Calibration accessories
Operating manual
Cable extension for probe
Ascertainable measured values and functions
Internal sensors
Layer thickness [µm]
External sensors
Minimum value display
Maximum value display
Average value display
Automatic switch-off
Backlit display
Acoustic alarm function
Sensor for ferromagnetic ground
Sensor for non-ferrous metal ground
Two-point calibration
Standard deviation
Battery status indication
Error indicator for incorrect measuring
Bluetooth

 standard equipment

 optionally available

 not available