Technical data |
Article number |
3.510.205.022
|
3.510.205.023
|
3.510.205.025
|
3.510.206.025
|
3.510.205.031
|
3.510.206.031
|
3.510.205.035
|
3.510.207.505
|
3.510.207.600
|
3.510.207.650
|
Electrode length [mm] |
|
|
|
|
|
|
40
|
|
|
|
Min. penetration depth (non-destructive) [mm] |
|
|
|
|
|
|
0
|
|
|
|
Max. penetration depth (non-destructive) [mm] |
|
|
|
|
|
|
50
|
|
|
|
Min. measuring range | Wood moisture [%] |
6
|
6
|
6
|
6
|
|
|
|
0
|
|
|
Max. measuring range | Wood moisture [%] |
44
|
60
|
44
|
50
|
|
|
|
100
|
|
|
Resolution | Wood moisture [%] |
1
|
1
|
1
|
1
|
|
|
|
0.1
|
|
|
Approx. accuracy ± | Wood moisture [%] |
2
|
1
|
|
2
|
|
|
|
|
|
|
Min. temperature compensation [%] |
|
|
|
|
|
|
|
0
|
|
|
Max. temperature compensation [%] |
|
|
|
|
|
|
|
60
|
|
|
Measuring principle |
resistance measuring method
|
resistance measuring method
|
resistance measuring method
|
resistance measuring method
|
|
|
|
resistance measuring method
|
|
|
Accuracy | Wood moisture [%] |
|
|
|
|
|
|
|
1
|
|
|
Min. measuring range | Material moisture [%] |
0.2
|
0.2
|
0.2
|
0.2
|
|
|
|
|
|
|
Max. measuring range | Material moisture [%] |
2
|
2.9
|
2
|
2.4
|
|
|
|
|
|
|
Resolution | Material moisture [%] |
0.1
|
0.1
|
0.05
|
0.05
|
|
|
|
|
|
|
Measuring principle |
resistance measuring method
|
resistance measuring method
|
resistance measuring method
|
|
|
|
|
|
|
Capacitive
|
Accuracy | Material moisture [%] |
|
|
|
|
|
|
|
|
|
|
Min. approx. measuring range | Material moisture [%] |
|
|
0.2
|
|
|
|
|
|
|
|
Approx. accuracy ± | Material moisture [%] |
|
|
|
0.2
|
|
|
|
|
|
|
Min. measuring range [%] |
|
|
|
|
|
|
|
|
|
0
|
Max. measuring range [%] |
|
|
|
|
|
|
|
|
|
7.6
|
Accuracy [%] ± | Material moisture cementitious screed (combined) |
|
|
|
|
|
|
|
|
|
±0.1 %
|
Min. measuring range | solid brick [%] |
|
|
|
|
|
|
0
|
|
|
|
Messbereich max. [%] |
|
|
|
|
|
|
20
|
|
|
|
Accuracy [%] | brick |
|
|
|
|
|
|
< 2
|
|
|
|
Min. measuring range | Material moisture [Digit] |
|
|
|
|
0
|
0
|
|
0
|
1
|
1
|
Max. measuring range | Material moisture [Digit] |
|
|
|
|
100
|
100
|
|
100
|
200
|
200
|
Accuracy |
|
|
|
|
1
|
|
|
0.1
|
0.1
|
0.1
|
Resolution [Digit] |
|
|
|
|
1
|
0.1
|
|
0.1
|
0.1
|
0.1
|
Measuring principle |
|
|
|
|
Dielectric/capacitive
|
Dielectric / capacitive
|
|
resistance measuring method
|
Microwave
|
Capacitive
|
Min. penetration depth (non-destructive) [mm] |
|
|
|
|
5
|
|
|
|
|
|
Max. penetration depth (non-destructive) [mm] |
|
|
|
|
40
|
40
|
|
|
300
|
40
|
Accuracy - Approx. temperature ± [°C] |
1
|
|
|
|
|
|
|
|
|
|
Min. temperature [°C] |
|
|
0
|
|
|
|
|
|
|
|
Max. temperature [°C] |
|
|
40
|
|
|
|
|
|
|
|
Min. temperature [°F] |
|
|
32
|
|
|
|
|
|
|
|
Max. temperature [°F] |
|
|
104
|
|
|
|
|
|
|
|
Approx. penetration depth (coupling) [mm] |
|
|
|
|
|
|
|
10
|
|
|
Min. measuring range | anhydrite screed [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | anhydrite screed [%] |
|
|
|
|
|
|
20
|
|
|
|
Accuracy [%] | anhydrite screed |
|
|
|
|
|
|
< 2
|
|
|
|
Min. measuring range | cement screed [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | cement screed [%] |
|
|
|
|
|
|
20
|
|
|
|
Accuracy [%] | cement screed |
|
|
|
|
|
|
< 2
|
|
|
|
Min. measuring range | sand-lime brick [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | sand-lime brick [%] |
|
|
|
|
|
|
20
|
|
|
|
Accuracy [%] | sand-lime brick |
|
|
|
|
|
|
< 2
|
|
|
|
Min. measuring range | gas concrete [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | gas concrete [%] |
|
|
|
|
|
|
20
|
|
|
|
Accuracy [%] | gas concrete |
|
|
|
|
|
|
<2 (with measured value > 8 %)
|
|
|
|
Min. measuring range | high-insulating brick [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | high-insulating brick [%] |
|
|
|
|
|
|
20
|
|
|
|
Accuracy [%] | high-insulating brick |
|
|
|
|
|
|
< 3
|
|
|
|
Min. measuring range | concrete [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | concrete [%] |
|
|
|
|
|
|
20
|
|
|
|
Accuracy [%] | concrete |
|
|
|
|
|
|
< 3
|
|
|
|
Min. measuring range | hardwood [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | hardwood [%] |
|
|
|
|
|
|
50
|
|
|
|
Accuracy [%] | hardwood |
|
|
|
|
|
|
<5 (with measured value > 9 %)
|
|
|
|
Min. measuring range | softwood [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | softwood [%] |
|
|
|
|
|
|
50
|
|
|
|
Accuracy [%] | softwood |
|
|
|
|
|
|
<5 (with measured value > 9 %)
|
|
|
|
Min. measuring range | chipboard [%] |
|
|
|
|
|
|
0
|
|
|
|
Max. measuring range | chipboard [%] |
|
|
|
|
|
|
50
|
|
|
|
Accuracy [%] | chipboard |
|
|
|
|
|
|
<5 (with measured value > 9 %)
|
|
|
|
Min. temperature [°C] |
|
|
|
|
|
|
-10
|
|
|
|
Max. temperature [°C] |
|
|
|
|
|
|
55
|
|
|
|
Accuracy - Approx. temperature ± [°C] |
|
|
|
|
|
|
2
|
|
|
|
Resolution [°C] |
|
|
|
|
|
|
1
|
|
|
|
Wood [%] |
|
|
|
|
|
|
0.1
|
|
|
|
Mineral building materials [%] |
|
|
|
|
|
|
0.1
|
|
|
|
Material moisture |
|
|
|
|
|
|
0.5 s
|
|
|
|
LCD |
|
|
|
|
|
|
|
|
|
|
Monochrome |
|
|
|
|
|
|
|
|
|
|
4.0 (BLE) |
|
|
|
|
|
|
|
|
|
|
Max. transmission range |
|
|
|
10 m in open terrain
|
|
10 m in open terrain
|
|
|
|
|
Push buttons |
|
|
|
|
|
|
|
|
|
|
Thumbwheel |
|
|
|
|
|
|
|
|
|
|
Membrane keyboard |
|
|
|
|
|
|
|
|
|
|
Touch key display |
|
|
|
|
|
|
|
|
|
|
Plastics |
|
|
|
|
|
|
|
|
|
|
Electrode length [mm] |
8
|
8
|
8
|
8
|
|
|
|
|
|
|
Internal (battery) |
4 x 1.5 V, LR44
|
1 x 9 V battery
|
4 x 1.5 V, AAA
|
|
1 x 9 V battery
|
|
1 x 9 V battery
|
4 x 1.5V, AA
|
4 x 1.5V, AA
|
4 x 1.5V, AA
|
Operation - min. temperature [°C] |
0
|
0
|
0
|
-20
|
0
|
0
|
-5
|
0
|
0
|
0
|
Operation - max. temperature [°C] |
50
|
40
|
40
|
60
|
50
|
50
|
50
|
50
|
50
|
50
|
Operation – min. relative humidity [%RH] |
0
|
0
|
0
|
|
|
|
|
|
|
|
Operation - max. relative humidity [%RH] |
85
|
85
|
85
|
|
80
|
|
85
|
|
95
|
95
|
Operation – min. relative humidity [%r.F.] |
|
|
|
10
|
|
10
|
|
|
|
|
Operation - max. relative humidity [%r.F.] |
|
|
|
90
|
|
90
|
|
90
|
|
|
Relative humidity during storage [%] |
|
|
|
< 80% RH
|
|
< 80% RH
|
|
|
|
|
Storage - min. temperature [°C] |
|
|
|
|
|
|
-10
|
|
|
|
Storage - max. temperature [°C] |
|
|
|
|
|
|
55
|
|
|
|
Length (packaging excluded) [mm] |
96
|
122
|
155
|
22
|
180
|
22
|
168
|
187
|
191
|
209
|
Width (packaging excluded) [mm] |
20
|
45
|
34
|
33
|
35
|
36
|
35
|
63
|
65
|
63
|
Height (packaging excluded) [mm] |
40
|
51
|
52
|
140
|
45
|
160
|
75
|
35
|
65
|
35
|
(packaging excluded) [kg] |
0.083
|
0.115
|
0.135
|
|
0.18
|
0.093
|
0.22
|
0.28
|
0.425
|
0.285
|
Standard scope of delivery |
Measuring device |
|
|
|
|
|
|
|
|
|
|
Protective cap |
|
|
|
|
|
|
|
|
|
|
Electrode tips (2.2 x 8 mm) |
|
|
|
|
|
|
|
|
|
|
Operating manual |
|
|
|
|
|
|
|
|
|
|
Wrist strap |
|
|
|
|
|
|
|
|
|
|
Battery(-ies) |
|
|
|
|
|
|
|
|
|
|
Electrode tips (1.5 x 20 mm) |
|
|
|
|
|
|
|
|
|
|
2 x union nuts |
|
|
|
|
|
|
|
|
|
|
Wood type directory |
|
|
|
|
|
|
|
|
|
|
Factory test certificate |
|
|
|
|
|
|
|
|
|
|
Ascertainable measured values and functions |
Ambient temperature [°C] |
|
|
|
|
|
|
|
|
|
|
Material moisture [%] |
|
|
|
|
|
|
|
|
|
|
Wood moisture [%] |
|
|
|
|
|
|
|
|
|
|
Material moisture [digits] |
|
|
|
|
|
|
|
|
|
|
Material moisture (capacitive) |
|
|
|
|
|
|
|
|
|
|
Switching function °C/°F |
|
|
|
|
|
|
|
|
|
|
Automatic battery test |
|
|
|
|
|
|
|
|
|
|
Data export |
|
|
|
|
|
|
|
|
|
|
Representation of measurement data as chart, matrix or table |
|
|
|
|
|
|
|
|
|
|
Long-term measurement function |
|
|
|
|
|
|
|
|
|
|
Alarm function |
|
|
|
|
|
|
|
|
|
|
Average value display |
|
|
|
|
|
|
|
|
|
|
Backlit display |
|
|
|
|
|
|
|
|
|
|
LED moisture indicator |
|
|
|
|
|
|
|
|
|
|
Retaining clip |
|
|
|
|
|
|
|
|
|
|
Mode selection slide control |
|
|
|
|
|
|
|
|
|
|
Non-destructive measurement method |
|
|
|
|
|
|
|
|
|
|
Display illumination |
|
|
|
|
|
|
|
|
|
|
Automatic functional test |
|
|
|
|
|
|
|
|
|
|
Material selection |
|
|
|
|
|
|
|
|
|
|
Manual temperature setting |
|
|
|
|
|
|
|
|
|
|
Temperature compensation |
|
|
|
|
|
|
|
|
|
|
Selection of wood material characteristics (Mat) |
|
|
|
|
|
|
|
|
|
|
Unit 2 |
|
|
|
|
|
|
|
|
|
|
Selection sensor characteristic map (sens) |
|
|
|
|
|
|
|
|
|
|
Acoustic alarm function |
|
|
|
|
|
|
|
|
|
|
Measured value hold function |
|
|
|
|
|
|
|
|
|
|
Minimum value display |
|
|
|
|
|
|
|
|
|
|
Maximum value display |
|
|
|
|
|
|
|
|
|
|
Battery status indication |
|
|
|
|
|
|
|
|
|
|
Automatic switch-off |
|
|
|
|
|
|
|
|
|
|
Backlit LCD monitor |
|
|
|
|
|
|
|
|
|
|
Report generation function |
|
|
|
|
|
|
|
|
|
|