Show all x BM12 x BM18 x BM22 x BM22WP x BM31 x BM31WP x BM40 x T510 x T610 x T660
BM12
BM18
BM22
BM22WP
BM31
BM31WP
BM40
T510
T610
T660

Technical data Standard scope of delivery Ascertainable measured...

You save: 10 %

18.95 £ 16.95 £ incl. VAT Show net price (VAT not included)

You save: 18 %

26.95 £ 21.95 £ incl. VAT Show net price (VAT not included)

You save: 38 %

33.95 £ 20.95 £ incl. VAT Show net price (VAT not included)

You save: 17 %

84.95 £ 69.95 £ incl. VAT Show net price (VAT not included)

You save: 15 %

94.95 £ 79.95 £ incl. VAT Show net price (VAT not included)

You save: 17 %

84.95 £ 69.95 £ incl. VAT Show net price (VAT not included)

You save: 15 %

94.95 £ 79.95 £ incl. VAT Show net price (VAT not included)

179.95 £ incl. VAT Show net price (VAT not included)

549.95 £ incl. VAT Show net price (VAT not included)

229.95 £ incl. VAT Show net price (VAT not included)

Technical data
General information
Article number 3.510.205.022 3.510.205.023 3.510.205.025 3.510.206.025 3.510.205.031 3.510.206.031 3.510.205.035 3.510.207.505 3.510.207.600 3.510.207.650
Measuring principle
Electrode length [mm] 40
Min. penetration depth (non-destructive) [mm] 0
Max. penetration depth (non-destructive) [mm] 50
Wood moisture [%]
Min. measuring range | Wood moisture [%] 6 6 6 6 0
Max. measuring range | Wood moisture [%] 44 60 44 50 100
Resolution | Wood moisture [%] 1 1 1 1 0.1
Approx. accuracy ± | Wood moisture [%] 2 1 2
Min. temperature compensation [%] 0
Max. temperature compensation [%] 60
Measuring principle resistance measuring method resistance measuring method resistance measuring method resistance measuring method resistance measuring method
Accuracy | Wood moisture [%] 1
Material moisture [%]
Min. measuring range | Material moisture [%] 0.2 0.2 0.2 0.2
Max. measuring range | Material moisture [%] 2 2.9 2 2.4
Resolution | Material moisture [%] 0.1 0.1 0.05 0.05
Measuring principle resistance measuring method resistance measuring method resistance measuring method Capacitive
Accuracy | Material moisture [%]
Min. approx. measuring range | Material moisture [%] 0.2
Approx. accuracy ± | Material moisture [%] 0.2
Min. measuring range [%] 0
Max. measuring range [%] 7.6
Accuracy [%] ± | Material moisture cementitious screed (combined) ±0.1 %
Solid brick
Min. measuring range | solid brick [%] 0
Messbereich max. [%] 20
Accuracy [%] | brick < 2
Material moisture [digits]
Min. measuring range | Material moisture [Digit] 0 0 0 1 1
Max. measuring range | Material moisture [Digit] 100 100 100 200 200
Accuracy 1 0.1 0.1 0.1
Resolution [Digit] 1 0.1 0.1 0.1 0.1
Measuring principle Dielectric/capacitive Dielectric / capacitive resistance measuring method Microwave Capacitive
Min. penetration depth (non-destructive) [mm] 5
Max. penetration depth (non-destructive) [mm] 40 40 300 40
Accuracy - Approx. temperature ± [°C] 1
Min. temperature [°C] 0
Max. temperature [°C] 40
Min. temperature [°F] 32
Max. temperature [°F] 104
Approx. penetration depth (coupling) [mm] 10
Anhydrite screed
Min. measuring range | anhydrite screed [%] 0
Max. measuring range | anhydrite screed [%] 20
Accuracy [%] | anhydrite screed < 2
Cement screed
Min. measuring range | cement screed [%] 0
Max. measuring range | cement screed [%] 20
Accuracy [%] | cement screed < 2
Sand-lime brick
Min. measuring range | sand-lime brick [%] 0
Max. measuring range | sand-lime brick [%] 20
Accuracy [%] | sand-lime brick < 2
Gas concrete
Min. measuring range | gas concrete [%] 0
Max. measuring range | gas concrete [%] 20
Accuracy [%] | gas concrete <2 (with measured value > 8 %)
High-insulating brick
Min. measuring range | high-insulating brick [%] 0
Max. measuring range | high-insulating brick [%] 20
Accuracy [%] | high-insulating brick < 3
Concrete
Min. measuring range | concrete [%] 0
Max. measuring range | concrete [%] 20
Accuracy [%] | concrete < 3
Hardwood
Min. measuring range | hardwood [%] 0
Max. measuring range | hardwood [%] 50
Accuracy [%] | hardwood <5 (with measured value > 9 %)
Softwood
Min. measuring range | softwood [%] 0
Max. measuring range | softwood [%] 50
Accuracy [%] | softwood <5 (with measured value > 9 %)
Chipboard
Min. measuring range | chipboard [%] 0
Max. measuring range | chipboard [%] 50
Accuracy [%] | chipboard <5 (with measured value > 9 %)
Temperature
Min. temperature [°C] -10
Max. temperature [°C] 55
Accuracy - Approx. temperature ± [°C] 2
Resolution [°C] 1
Resolution
Wood [%] 0.1
Mineral building materials [%] 0.1
Measurement rate
Material moisture 0.5 s
Display
LCD
Monochrome
Bluetooth
4.0 (BLE)
Max. transmission range 10 m in open terrain 10 m in open terrain
Device control
Push buttons
Thumbwheel
Membrane keyboard
Touch key display
Housing design
Plastics
Electrode length [mm] 8 8 8 8
Power supply
Internal (battery) 4 x 1.5 V, LR44 1 x 9 V battery 4 x 1.5 V, AAA 1 x 9 V battery 1 x 9 V battery 4 x 1.5V, AA 4 x 1.5V, AA 4 x 1.5V, AA
Ambient conditions
Operation - min. temperature [°C] 0 0 0 -20 0 0 -5 0 0 0
Operation - max. temperature [°C] 50 40 40 60 50 50 50 50 50 50
Operation – min. relative humidity [%RH] 0 0 0
Operation - max. relative humidity [%RH] 85 85 85 80 85 95 95
Operation – min. relative humidity [%r.F.] 10 10
Operation - max. relative humidity [%r.F.] 90 90 90
Relative humidity during storage [%] < 80% RH < 80% RH
Storage - min. temperature [°C] -10
Storage - max. temperature [°C] 55
Dimensions
Length (packaging excluded) [mm] 96 122 155 22 180 22 168 187 191 209
Width (packaging excluded) [mm] 20 45 34 33 35 36 35 63 65 63
Height (packaging excluded) [mm] 40 51 52 140 45 160 75 35 65 35
Weight
(packaging excluded) [kg] 0.083 0.115 0.135 0.18 0.093 0.22 0.28 0.425 0.285
Standard scope of delivery
Standard scope of delivery
Measuring device
Protective cap
Electrode tips (2.2 x 8 mm)
Operating manual
Wrist strap
Battery(-ies)
Electrode tips (1.5 x 20 mm)
2 x union nuts
Wood type directory
Factory test certificate
Ascertainable measured values and functions
Internal sensors
Ambient temperature [°C]
Material moisture [%]
Wood moisture [%]
Material moisture [digits]
Material moisture (capacitive)
Functions and features
Switching function °C/°F
Automatic battery test
Data export
Representation of measurement data as chart, matrix or table
Long-term measurement function
Alarm function
Average value display
Backlit display
LED moisture indicator
Retaining clip
Mode selection slide control
Non-destructive measurement method
Display illumination
Automatic functional test
Material selection
Manual temperature setting
Temperature compensation
Selection of wood material characteristics (Mat)
Unit 2
Selection sensor characteristic map (sens)
Acoustic alarm function
Measured value hold function
Minimum value display
Maximum value display
Battery status indication
Automatic switch-off
Backlit LCD monitor
Report generation function

 standard equipment

 optionally available

 not available